Steelcase V.I.A. FEIJA2V Скачать руководство пользователя страница 1

Page 1 of 38

939502326 Rev G

If you have a problem, question, or request, call
your local dealer, or Steelcase Line 1 at
888.STEELCASE (888.783.3522)
for immediate action by people who want to help you.
(Outside the U.S.A., Canada, Mexico, Puerto Rico, 
and the U.S. Virgin Islands, call: 1.616.247.2500)
Or visit our website: www.steelcase.com

©

 

2017 Steelcase Inc. 

Grand Rapids, MI 49501 
U.S.A.  
Printed in U.S.A.

CAUTION

FAILURE TO PROPERLY SECURE
V.I.A. TO THE BUILDING COULD
RESULT IN PERSONAL INJURY.

CRUSH HAZARD!

Read the entire Assembly Directions
before beginning installation.
Building construction varies greatly. The
Building’s Engineer of Record is responsible
for the design of building floors, ceilings
and walls which V.I.A. attaches to and must
verify the adequancy of the mounting
even if provided by Steelcase.
The building owner or designated agent is
responsible for verifying that the
installation is in compliance with all local
codes and regulations.

Non-Seismic Applications*
*

 The building’s Engineer of Record must be

consulted to determine if there are any
seismic requirements.

V.I.A.

 - Frames & Structure

Installation Reference Identification (IRID) Label example shown above. 
Many V.I.A. Products have specific locations within the floor plan layout. 
These products will be identified with an Installation Reference Identification Label. 
The Installation Reference ID Label number will indicate the location of the product 
within the floor plan layout. Detailed information can be found on the label 
including style/model number, finish, Plan dimensions, Measured dimensions etc....

By Steelcase Inc.  Grand Rapids, MI 49501-1967

www.steelcase.com/patents

Model:  FEIJA2V

Ship Date:  10/09/13 Athens

Order No.:  05207605-001160

Barcode:  1PN8Z952O

Assembled By:  F529602

Finishes  

6249

J0DEF

PH: 108.000 MH: 105.618

Содержание V.I.A. FEIJA2V

Страница 1: ...y Steelcase The building owner or designated agent is responsible for verifying that the installation is in compliance with all local codes and regulations Non Seismic Applications The building s Engineer of Record must be consulted to determine if there are any seismic requirements V I A Frames Structure Installation Reference Identification IRID Label example shown above Many V I A Products have...

Страница 2: ...l Horizontal Installation Intermediate Horizontal Installation Partial Height Vertical Post Installation Base Trim Installation Base Trim Removal Process Acoustic Block Installation Assembling a Junction Kit to a Junction Assembling a Mini End to a Junction Changing Acoustic Seals 3 4 5 8 9 18 19 20 21 22 23 24 25 26 27 28 29 30 33 34 34 35 36 37 38 7 16 1 2 PUTTY KNIFE BASE TRIM INSTALLATION TOOL...

Страница 3: ...o CL CL to ME 120 26 CL to outside FE 3 3 4 119 1 4 CL to outside of FE 38 86 Ceiling Height 114 116 Elevation A 38 69 Ceiling Height 114 34 48 34 Elevation B 1 38 86 Ceiling Height 114 40 100 Elevation C 1 38 86 Ceiling Height 114 23 Elevation D 1 38 86 Ceiling Height 114 23 100 40 Elevation E 38 86 Ceiling Height 114 114 Elevation F 38 86 Ceiling Height 114 114 Elevation G Automatic Elevations C...

Страница 4: ...for common ceiling track conditions Transfer the ceiling centerline to the floor by means of laser transits or plumb bob Make sure that the tape or lines are not visible after install is complete For the best results use a 5 point alignment self leveling laser to transfer lines plumb level and square to within 1 32 of an inch The most accurate feature to reference while leveling is the vertical po...

Страница 5: ...bly Nylon Washer 1 4 20 Hex Nut 10 24 Caddy Clip Assembly 10 24 Hex Nut 1 4 20 Caddy Clip Assembly Nylon Washer 1 4 20 Hex Nut 1 4 20 Caddy Clip Assembly Nylon Washers 1 4 20 Hex Nut 10 24 Ceiling Clip Assembly Tinnerman Clip Channel Mounting Options The building s designated design professional Architect or Engineer must verify that the ceiling grid is adequate to support lateral loads imposed by...

Страница 6: ...or x 2 7 17 x 1 Bugle Head Self Drilling Screws Generic Sheet Metal Screw Generic Sheet Metal Screw Nylon Washer 5 16 18 Screw 1 4 20 Donn Bolt Nylon Washer 1 4 20 Hex Nut Nylon Washer Channel Mounting Options Continued The building s designated design professional Architect or Engineer must verify that the ceiling grid is adequate to support lateral loads imposed by V I A Local codes may require ...

Страница 7: ...on ceiling conditions Connections should be made at least every four feet for normal duty and at least every two feet for heavy duty and along straight runs and within eight inches of the end of any run Each off module connection or junction should also have a connection within eight inches of the joint 1a 1b splice together ceiling joints supplied one per ceiling channel 1 EXPOSED CLIP SHOWN ONE ...

Страница 8: ...o accommodate the ceiling track clips If the channel is cut it may be helpful to add a piece of tape to one end This maintains alignment between the seal and steel channel while attaching the channel to the ceiling SEAL TO ONE SIDE OF CEILING CLIP AND WASHER STACK TEGULAR CEILING GRID SEAL SEAL SEAL CEILING CLIP CEILING TRACK INLINE WITH GRID CEILING TRACK PERPENDICULAR TO GRIDS CEILING TRACK DIAG...

Страница 9: ...hen installing ceiling track butt joints center the splice as shown 2 A feature of the straight ceiling track is the center hole spacing matches most ceiling grids 3 Two self tapping screws are provided to secure the splice connection after the ceiling track 1 NOTE Specifiable angle ceiling track will have an installation reference ID label placed on it and has a specific location in the floor pla...

Страница 10: ...e Square cuts will insure best appearence When routing power or communication sheet metal shears can be used to cut a hole in the top of the ceiling track Avoid cutting the side of the ceiling track because these cuts will be visible 4 To create a tight fit when a corner ceiling track lacks structure a wood block can be installed above the ceiling tile for reinforcement CORNER CEILING TRACK 4 WOOD...

Страница 11: ... for information on available ceiling fastener types and locations Showing typical ceiling fastener for general installation purposes 6 Take care to insure that the ceiling track seal seats consistently 5b CADDY CLIP 6 5a Install ceiling track flush against building wall if floor plan indicates ...

Страница 12: ...ach with self drilling screw to the ceiling track 7b Aligning to the centerline of the floor plan hook ceiling track bracket 7c to the other ceiling track and attach with self drilling screw as shown 7d Repeat the process on the other side if an X intersection is required 7e 7d 7b 7e FLOOR PLAN CENTERLINE CEILING TRACK BRACKET HOOK TO CEILING TRACK CEILING TRACK BRACKET 1 16 BACK 7a 7b 7c ...

Страница 13: ...3 of 38 939502326 Rev G CEILING TRACK INSTALLATION cont CENTERLINE OF CEILING TRACK ANGLE CAN RANGE FROM 90 o TO 179 o CEILING TRACK CORNERS 24 24 2 5 16 WIDE CEILING TRACK 1 5 32 HALF WIDTH OF CEILING TRACK ...

Страница 14: ...ev G CEILING TRACK INSTALLATION cont ANGLE CAN RANGE FROM 90 o TO 179 o 2 WAY JUNCTIONS 90 o 120 o 135 o 180 o AND SPECIFIABLE ANGLES FROM 91o THROUGH 179 o 2 1 32 CENTERLINE OF CEILING TRACK 2 1 32 4 1 16 180 o INLINE JUNCTION ...

Страница 15: ...BUTT STRAIGHT CEILING TRACK 2 1 32 4 1 16 STRAIGHT CEILING TRACK 7 8 1 5 32 1 11 32 2 1 32 TYPICAL NOTCH AND BUTT STRAIGHT CEILING TRACK CENTERLINE OF CEILING TRACK 120o CEILING TRACK CORNER 1 9 16 2 1 32 TYPICAL NOTCH AND BUTT STRAIGHT CEILING TRACK CENTERLINE OF CEILING TRACK 90 o CEILING TRACK CORNER ...

Страница 16: ...nt 4 WAY JUNCTION 2 1 32 TYPICAL BUTT STRAIGHT CEILING TRACK STRAIGHT CEILING TRACK THROUGH 7 8 1 5 32 BUTT STRAIGHT CEILING TRACK 4 1 16 TYPICAL STRAIGHT CEILING TRACK FINISHED END TRIM 1 2 CEILING TRACK PAST THE CENTERLINE OF THE VERTICAL POST FINISHED END 1 ...

Страница 17: ...TOR NOTCH AND BUTT STRAIGHT CEILING TRACK 1 5 32 2 5 16 STRAIGHT CEILING TRACK TRAPPED SKINS T ADAPTOR TRIM 1 27 32 EDGE OF CEILING TRACK TO CENTERLINE OF VERTICAL POST 3 CENTERLINE OF WALL TO CENTERLINE OF VERTICAL POST NOTE An X adaptor is two 2 T adaptors back to back ...

Страница 18: ...M NOT SHOWN CEILING TRACK EXTENDS TO THE WALL 2 5 8 MID 3 3 4 MID 5 5 8 MID SMALL RANGE 2 1 4 to 3 LARGE RANGE 4 1 2 to 6 3 4 MEDIUM RANGE 3 to 4 1 2 CUTSKIN APPLICATIONS CEILING TRACK EXTENDS TO THE BUILDING WALL REFER TO ASSEMBLY DIRECTION 939502322 FOR INSTALLATION PROCESS ...

Страница 19: ...e it s easier to adjust in two directions rather than 3 or 4 start with the largest junctions in any given layouts Using Figure 1 for an example Start with the 4 way junction and work toward the 3 way junctions in all directions then work toward the 2 way junctions 4 WAY 3 WAY 3 WAY 2 WAY 2 WAY FIGURE 1 ...

Страница 20: ...ntial to deliver 1 200 pounds per leveler screw to floor condition Leveler screws loaded to 1 200 pounds will exert local pressure loading of 11 000 PSI Floor type Steelcase product application must be properly matched in accordance with local building codes and floor condition to avoid flooring damage and ensure proper performance of Steelcase Wall Systems Chalk Line Floor Guide Base Track Base T...

Страница 21: ...RIZONTAL RAIL MOUNTING EIGHT 8 HOLE PATTERN S IF PRESENT FURNITURE SLOTS UNDER SEAL LENGTH OF PART SLOT PITCH HOLES LENGTH OF PART POWER COMMUNICATION PASS THRU SYSTEM HOLE VARIOUS V I A PRODUCTS WILL REFERENCE THIS HOLE BRACKET MOUNTING HOLES ACOUSTIC SEAL IRID LABEL LEVELER BRACKET STRUCTURAL CORNER BRACKETS FACTORY SCREWS T30 DRIVE POST EXTENSION SHOWN REMOVED PARTIAL HEIGHT VERTICAL POST ASSEM...

Страница 22: ...ertical post needs reconfiguring Common applications are removing or replacing brackets when a vertical post is next to a door Finished End Mini End etc Examples shown here are for general reference Refer to the appropriate product assembly direction for more details USE A T30 DRIVER TO RECONFIGURE BRACKETS WHEN REQUIRED DOOR OPENING SIDE END SIDE TYPICAL DOOR APPLICATION REMOVE BOTTOM CORNER BRAC...

Страница 23: ...nfigurations at the bottom of the post 3 Temporarily postion the post as vertical as possible Adjust the leveler to apply enough tension to keep the post from coming out of the ceiling track NOTE A partial height vertical post is attached to the intermediate rail with fasteners in a similar method not shown here CAUTION Until vertical post is fastened to a structural horizontal rail it should be c...

Страница 24: ...horizontal rail mounting pattern when present even though not all locations call for horizontals Refer to vertical post assembly features page 21 Verifying each vertical has the same number and location of hole patterns will help to indicate that junctions were assembled correctly in the factory NOTE See pages 35 36 for special junction configurations NOTE If acoustic seal color change is required...

Страница 25: ... ladder with two 2 putty knives guide top of junction assembly into the ceiling track while another installer on the floor angles the bottom of the junction assembly as shown 2 Slowly move the bottom of the junction assembly to the wall centerline as the installer on the ladder ensures the seals and post are guided into the ceiling track 3 Postion levelers on the wall centerlines Junction assembly...

Страница 26: ...e transfer line per the layout drawing 3 Install floor track springs into spring slots 4 Use the splice to align two 2 adjacent floor tracks 5 Lift vertical post up and into the hole within the splice 1 IRID Label Contains Width Information Acoustic Seals Glide Slots Power Communication Pass Through Spring Slot Splice Floor Track Spring Hook spring wire into slot and twist until spring stands as s...

Страница 27: ...al horizontal by compressing over floor track springs and secure with four 4 two per post M6 1 x 17mm screws with a T30 torx drive bit FEPF01 Power Communication Pass Through NOTE Consider electrical communication routing needs with respect to the power communication pass through holes IRID Label Contains Width Information Acoustic Seals Door Frame Opening Structural Horizontal Single Vertical Pos...

Страница 28: ...re the use of a nut plate shown The nut plate is used when an intermediate horizontal is located next to certain junctions or mini ends that won t allow driver access Pay attention to the sequence of assembly as the nut plate needs to be installed prior to door frames mini ends finished ends NOTE When a intermediate horizontal is used over a transom high door flip one intermediate bracket and orie...

Страница 29: ...ng INTERMEDIATE HORIZONTAL Refer to the IRID label and layout drawing to determine product location orientation mounting holes for partial height vertical post 1 The partial height vertical post installs identical to the full height vertical post at the base 2 Attach partial height vertical post to intermediate horizontal by installing four 4 M6 1 x 17mm screws with a T30 torx drive bit FEPF01 ACO...

Страница 30: ... Angle Corner FEBTS Base Trim Straight 90 o Base Trim Specifiable Angle Range A 91 o through 179 o Base Trim 120 o Base Trim 135o Base Trim 10 Foot Base Trim 12 Foot Base Trim Profile of Base Trim Base Trim Clip Inside Outside NOTE Refer to the Elevation Drawings to determine what color trims are to be installed ...

Страница 31: ...Applications Building Wall Mini End Wall Channel Cuttable Skin Wall Channel Start or Cut Straight Base Trim Flush to Wall Channel Start or Cut Straight Base Trim Flush to Building Wall Whenever possible butt factory ends together Minimizing the number of cut joints will improve the appearance of the product Base Trim Flush to 1 8 Door Opening 90 o Junction Next to a Door Cut Inside and Outside Cor...

Страница 32: ...p onto floor track flange 2 Use a mallet and base trim tool to seat base trim to the floor 3 If corners need cutting position corner next to junction and mark base trim flush to 1 8 back from vertical post side Cut and file the edge 1 1 2 3 Base Trim Clip Base Trim Tool Floor Track Flange ...

Страница 33: ...down into position from one end to the other 4 Carefully adjust base trim to avoid gaps at joints 1 2 3 4 Wood or Plastic Block Against Edge of Base Trim CAUTION Make sure the floor track flange is aligned as you install the base trim onto it If the flange is deformed in an area use a flat bladed screwdriver to adjust the straightness CAUTION Make sure floor track is aligned flush at joints as you...

Страница 34: ... brackets between the base trim and the floor Allow the acoustic block to expand and fill the space PUTTY KNIFE 1 2 If it becomes necessary to remove the base trim 1 Start from one end and insert a putty knife down into the floor track to prevent lifting 2 Carefully pry the end of the base trim off the floor track Work the base trim up by hand as you work toward the other end ...

Страница 35: ...ertical post to floor plan condition 2 Attach bottom block on first available slot above electrical cutout It may be required to unassemble vertical post from assembly junction 2b 3 Stagger remaining block to position close to assembled junction blocks Replace vertical post to assembled junction 4 Assemble vertical post to assembled junction ...

Страница 36: ... ribs of the mini end inner channel in area shown Do not drill through 2 Use a 1 4 dia drill bit and drill through pilot hole 3 Remove the M6 20mm long screw and use an M6 28mm long screw to attach to bottom junction block NOTE Use the mount to wall method to install mini end per Assembly Directions 939502321 with the following exceptions 2 ...

Страница 37: ...rmine if any reconfiguring is required see page 22 2 Once vertical post orientation is determined remove the acoustic seal from the side which requires changing 3 Use a heavy duty utility shear to cut replacement seal to the same length as the one being replaced Cut the ends as straight as possible 4 With the removed seal end as a guide use a sharp knife to trim away the bulbs on one end of the se...

Страница 38: ...res changing 9 Use a heavy duty utility shear to cut replacement seal to the same length as the one being replaced Cut the ends as straight as possible 10 Remove the tape release paper and replace the seal using the opposite side seal as a guide for placement NOTE Intermediate horizontal seals can be replaced after assembled to frame Remove and replace with correct color per elevation drawings Cut...