Maintenance
_______________________________________________________________
157238
15
7
Maintenance
7.1
Safety instructions
Only use suitable tools for all these
operations.
A damaged mains cable must be replaced
by the manufacturer, the manufacturer’s
customer service staff or similarly
qualified personnel to prevent hazards.
7.2
Functional check
The components of the
Solo Sit-to-Stand Desk
must be checked for correct functioning at regular
intervals. Pay particular attention to the electrical
connections:
■
The electrical equipment of the desk
must be checked regularly. Fix loose
connections or damaged cables
immediately.
■
Attach or detach connectors only
when the equipment is de-energised.
■
The plug of the desk must be easily
accessible at all times.
7.3
Table of functional checks
Interval
Inspection point
Functional check
Required condition
Measure
(if required)
During assembly
Frame parts
Lifting column position
Lifting columns
completely inserted
and screwed into the
horizontal structure
Unscrew screws, insert
lifting columns correctly
(direction and cable!) and
tighten the screws
Before each
height adjustment
Immediate
environment of the
desk
Check safety distance
No objects in the
lifting range
Remove any objects
Desktop
Check for horizontal
alignment
Horizontal
Align using the adjusting
screws on the feet
Regularly
Connections of the
electrical supply lines
(cables)
Check the insulation for
damage
No damage
Replace the connections
Insulation of the
electrical supply lines
(cables)
Check the insulation for
damage
No damage
Replace the cables
Surroundings of the
electrical supply lines
(cables)
Check clearance to hot
objects (e.g. radiators)
Sufficient distance
Establish distance
Table 7-1: Functional checks