How to power cycle (initialize)
the Control Box:
In the unlikely event an error occurs, and the
desk is unresponsive:
1. Unplug the desk Power Cord from the outlet.
2. Wait at least 10 seconds.
3. Reconnect power to the desk.
How to test Lifting Columns:
Lifting Column can be operated independently.
1. Obtain a Control Box that is known to work. Be sure the Control
Box is unplugged, or plugged in but in Standby mode.
2. Connect the Low-Voltage Cable of the Lifting Column to the
known-good Control Box. Connect only to Port/Channel 1
(farthest from the Power Cable).
3. Obtain a Controller that is known to work, and connect it to the
Control Box.
Tip: Verify that the Control Box software is current
when using the Active Touch controller.
4. If the Control Box is unplugged from the wall outlet, plug the
Power Cable back in.
5. With the system hot, operate the Lifting Column.
A. Can the Lifting Column be operated through its full range
of motion?
B. Does the Lifting Column appear to function normally?
Any faulty Lifting Column must be replaced. There are no
field-serviceable parts inside the Lifting Column.
1
3