Steca XP-COMPACT
XP-COMPACT
V5.5
8/57
3
Mounting and installing
3.1 Installation
place
The location of the XP-COMPACT must be driven by the following criteria:
−
Protection
from
unauthorized handling
−
Dry dust free room, no condensation
−
Never install directly over the battery and never in a cabinet together with the
batteries
−
Keep ventilation holes free
−
In mobile installations it is important to keep the vibrations down as low as
possible
3.2 Fixing
3.2.1 Fixing the XP-COMPACT
Basically the XP-COMPACT can be installed in any
desired location. Preferred is that the appliance be wall
mounted with battery cables downwards. The XP-
COMPACT is fixed on the wall with four screws through the
four holes (diameter 5.5mm) which are accessible from the
outside. In motor vehicles XP-COMPACT must be fixed on
vibrations reducing elements. The XP-COMPACT must not
be fixed on a combustible base, as the back of the casing
can get hot and reach up to 80 degree Celsius.
3.2.2 Protection cover IP-23
This cover IP23 (Order ref. CIP-23) can be easily
installed after the fixation of the XP-COMPACT. For that
release a little the too screws down and more the tow up.
Then it’s possible to pass the IP 23 cover between the
XP-COMPACT and the wall. The cover must touch the
screws. Lock on the four screws, it’s ready.
3.3 Connections
3.3.1 General instructions on connecting
−
The cable connection on the terminals AC INPUT / AC OUTPUT / 16A 230VAC
are carried out with a screwdriver Nr.1 and the connection on the SOLAR
terminal with a screwdriver Nr.2.
−
The conductor cross section on the terminals AC INPUT / AC OUTPUT / 16A
230VAC of the connecting cable must be minimum 2.5mm2.
−
All connecting cables and also the mounted battery cables, must be fixed with
strain relief clamps.
−
The XP-COMPACT is delivered with battery cables already connected.
−
The battery cables must never be extended. If the extension is unavoidable then
the conductor cross section must be elevated accordingly.
−
To protect the battery cable, a fuse corresponding to the conductor cross
section must be fixed directly on to the battery.
Содержание XPC 1400-12
Страница 27: ...Steca XP COMPACT XP COMPACT V5 5 27 57 8 Technical Data ...
Страница 41: ...Steca XP COMPACT XP COMPACT V5 5 41 57 4 2 Anzeigen und Bedienelemente für der Fernsteuerung Remote control ...
Страница 56: ...Steca XP COMPACT XP COMPACT V5 5 56 57 8 Technische Daten ...
Страница 57: ...Steca XP COMPACT XP COMPACT V5 5 57 57 ...
Страница 58: ......
Страница 59: ......
Страница 60: ...714828 ...