14
738.955 | 10.40
EN
Feeding
cable
through
rear
of
casing
(fig.
1):
WARNING
Risk
of
electrical
shock
and
fire
due
to
cables
com-
ing
loose!
Install an external strain relief for the cables.
Remove the plastic flaps
from the rear side of
the casing using an appropriate tool.
Feeding
the
cable
through
the
lower
side
of
the
casing
(fig.
2):
WARNING
Risk
of
electrical
shock
and
fire
due
to
cables
com-
ing
loose!
Fasten the cables to the casing using the strain-relief
clamps provided.
Cut the left and right plastic flaps
using an
appropriate tool and break them out of the casing.
4.3.2
Connecting
the
cables
If a protective conductor is provided or required
for the pump, connect the protective conductor
to the terminal clamps of the controller. When
connecting the protective conductor, observe the
following points:
Make sure that the grounding contact is also
connected to the controller's mains supply side.
NOTE
Observe the instructions in the ECM pump data sheet.
-
SET
6
Fig. 2: cable feed from below
SET
7
Fig. 1: cable feed from the rear