6.2.1  SOC window

Displays the charge state, day / night status 

and load on / off status.  

In the Voltage control operating mode, the 

battery voltage is displayed instead of the 

SOC value. 

In the Voltage control with bar display oper-

ating mode, the battery voltage is displayed 

both alphanumerically and as a bar display. 

6.2.2  Voltage window

Displays the battery voltage measured by 

the controller.

6.2.3  Module current

Displays the solar module output current.

6.2.4  Charging current

Displays the charging current into the 

battery.

6.2.5  Load current

Displays the current being consumed from 

the load output.

6.2.6  Ah – Battery charge meter

Displays the total Ah charged into the bat-

tery since initial installation or the last reset 

of the meter. Pressing and holding both but-

tons for 3 seconds resets the meter to 0. The 

value is retained when the battery is discon-

nected. After reaching a value of 99.9 kAh, 

the meter jumps back to 0 Ah.

6.2.7  Ah – Battery discharge meter

Displays the total Ah discharged via the 

load output since initial installation or the 

last reset of the meter. Pressing and holding 

both buttons for 3 seconds resets the meter 

to 0. The value is retained when the battery 

is disconnected. After reaching a value of 

99.9 kAh, the meter jumps back to 0 Ah.

Содержание PR 1010

Страница 1: ...Operating instructions Solar charge controller 10 A 15 A 20 A 30 A 739 704 11 10 EN...

Страница 2: ...arging current 8 6 2 5 Load current 8 6 2 6 Ah Battery charge meter 8 6 2 7 Ah Battery discharge meter 8 6 2 8 Deep discharge protection advance warning 9 6 2 9 Load disconnection 9 7 Functions 10 7 1...

Страница 3: ...If the device is installed abroad information on rules and protective measures must be obtained from the corresponding institutions authorities Do not start the installation until you are sure that yo...

Страница 4: ...alled in a manner providing protection from weathering influences such as rain and direct sunlight Ventilation openings must not be covered The controller may only be used for the specified intended p...

Страница 5: ...a suffi ciently large cross section to keep losses as low as possible e g 2 5 mm at 10 A and 2 m 4 mm at 20 A and 2 m 6 mm at 30 A and 2 m For correct functioning of the temperature compensation of t...

Страница 6: ...ttery can be damaged when the connection cable is short circuited Install a fuse in the battery connection cable to protect the battery Observe the following connection sequence when commissioning the...

Страница 7: ...em information The left button can be used to switch between the different display windows After the last window the first window is displayed once more The following figures show examples of system i...

Страница 8: ...6 2 5 Load current Displays the current being consumed from the load output 6 2 6 Ah Battery charge meter Displays the total Ah charged into the bat tery since initial installation or the last reset o...

Страница 9: ...oltage value Voltage control Voltage value and voltage bar display Voltage control with bar display The face symbol still looks happy 6 2 9 Load disconnection The following symbols flash when the deep...

Страница 10: ...tery until the final charge voltage is reached Once charge controlling takes place the charge current is controlled via pulse width modulated PWM shunting of the module input shunt charge controller D...

Страница 11: ...t rather relative to the point when the controller detects the transition from night to day This point can be influenced by bad weather fog or the natural seasonal changes in the lengths of day and ni...

Страница 12: ...charging method and deep discharge protection are controlled by the calculated SOC value If loads are directly connected to the battery and not to the controller or the battery is also charged from a...

Страница 13: ...connection After this period activating the function causes InF to be displayed left Fig Perform the self test as follows 1 Disconnect the solar module 2 Disconnect load 3 Disconnect the battery 4 Re...

Страница 14: ...e Possible causes Solar module and load were not disconnected before the test Check this and repeat the test if necessary Defective controller Contact your dealer for a more detailed examination or re...

Страница 15: ...external Steca bus 6 pin edge con nector Check the plug connection at the 6 pin edge connector check the power supply and check for correct functioning of external expansions If the error recurs then...

Страница 16: ...d with incorrect polarity Correct the short circuit at module input Sun symbol appears after 10 s Connect the module Sun symbol appears after 15 min Connect the module with the correct polarity No bat...

Страница 17: ...n of the fault is provided immediately after it is discovered Guarantee claims are to be directed to the seller The seller must be informed before guarantee claims are processed For processing a guara...

Страница 18: ...5 C Load switch on 75 C Data on final charge voltage Depending on configured battery type Gel battery GEL Liquid electrolyte Li Normal charging float 13 9 V 27 8 V 13 9 V 27 8 V Boost charging boost f...

Страница 19: ...r segments 12 8 V 25 6 V 8 bar segments 12 7 V 25 4 V 7 bar segments 12 5 V 25 0 V 6 bar segments 12 0 V 24 0 V 5 bar segments 11 7 V 23 4 V 4 bar segments 11 1 V 22 2 V 3 bar segments 11 0 V 22 0 V 2...

Страница 20: ...739704...

Отзывы: