739.704 | 11.10

7.5  Daylight function

This function allows a switch-on point for the load output to be defined 

that occurs during the night / darkness when daylight is detected. The aim 

is to switch on a load a specified number of hours before dawn. The load 

output remains switched off outside this period. 
The controller recognises Day (= sun symbol) when the module voltage is 

greater than the battery voltage and the battery can be charged. Recogni-

tion duration: approx. 30 s.  

This duration extends to 15 minutes, when Night was previously detected 

due to a solar module not being connected or a module with a reverse 

current diode was detected and the module was then correctly reconnected 

and battery charging took place.
The controller must first have recognised at least one night / day cycle 

before the daylight function can be activated. This means that the daylight 

function cannot be activated in the first night following the installation day. 

The function can only become active in the following night. 

The switching point is thus not based on a specific time of day but rather 

relative to the point when the controller detects the transition from night 

to day.
This point can be influenced by bad weather, fog or the natural seasonal 

changes in the lengths of day and night, so a certain amount of tolerance 

is required. This is especially the case when the natural conditions are 

interrupted by manual intervention such as disconnection or covering of the 

solar modules. Despite this, the controller recalculates the reference point 

for the daylight function after each night / day transition and therefore 

automatically adapts to the natural conditions after a few days.

Note

 

The daylight function 

is not 

executed when the time periods for 

the night light and daylight functions overlap. Overlap means: The 

switch-off point of the night light function lies after the switch-on 

point of the daylight function. When the night light function ends, 

then the daylight function will also end. An overlap of the time 

periods can be caused by:

•  Incorrect setting of the night light and daylight time periods by 

the user

•  Seasonal reductions in the length of the night

•  Poor weather (heavy cloud)

•  Covering of the module (snow)

Alternatively: Set the night light function to ON (load output 

remains switched on all night, regardless of the daylight function 

settings).

Содержание PR 1010

Страница 1: ...Operating instructions Solar charge controller 10 A 15 A 20 A 30 A 739 704 11 10 EN...

Страница 2: ...arging current 8 6 2 5 Load current 8 6 2 6 Ah Battery charge meter 8 6 2 7 Ah Battery discharge meter 8 6 2 8 Deep discharge protection advance warning 9 6 2 9 Load disconnection 9 7 Functions 10 7 1...

Страница 3: ...If the device is installed abroad information on rules and protective measures must be obtained from the corresponding institutions authorities Do not start the installation until you are sure that yo...

Страница 4: ...alled in a manner providing protection from weathering influences such as rain and direct sunlight Ventilation openings must not be covered The controller may only be used for the specified intended p...

Страница 5: ...a suffi ciently large cross section to keep losses as low as possible e g 2 5 mm at 10 A and 2 m 4 mm at 20 A and 2 m 6 mm at 30 A and 2 m For correct functioning of the temperature compensation of t...

Страница 6: ...ttery can be damaged when the connection cable is short circuited Install a fuse in the battery connection cable to protect the battery Observe the following connection sequence when commissioning the...

Страница 7: ...em information The left button can be used to switch between the different display windows After the last window the first window is displayed once more The following figures show examples of system i...

Страница 8: ...6 2 5 Load current Displays the current being consumed from the load output 6 2 6 Ah Battery charge meter Displays the total Ah charged into the bat tery since initial installation or the last reset o...

Страница 9: ...oltage value Voltage control Voltage value and voltage bar display Voltage control with bar display The face symbol still looks happy 6 2 9 Load disconnection The following symbols flash when the deep...

Страница 10: ...tery until the final charge voltage is reached Once charge controlling takes place the charge current is controlled via pulse width modulated PWM shunting of the module input shunt charge controller D...

Страница 11: ...t rather relative to the point when the controller detects the transition from night to day This point can be influenced by bad weather fog or the natural seasonal changes in the lengths of day and ni...

Страница 12: ...charging method and deep discharge protection are controlled by the calculated SOC value If loads are directly connected to the battery and not to the controller or the battery is also charged from a...

Страница 13: ...connection After this period activating the function causes InF to be displayed left Fig Perform the self test as follows 1 Disconnect the solar module 2 Disconnect load 3 Disconnect the battery 4 Re...

Страница 14: ...e Possible causes Solar module and load were not disconnected before the test Check this and repeat the test if necessary Defective controller Contact your dealer for a more detailed examination or re...

Страница 15: ...external Steca bus 6 pin edge con nector Check the plug connection at the 6 pin edge connector check the power supply and check for correct functioning of external expansions If the error recurs then...

Страница 16: ...d with incorrect polarity Correct the short circuit at module input Sun symbol appears after 10 s Connect the module Sun symbol appears after 15 min Connect the module with the correct polarity No bat...

Страница 17: ...n of the fault is provided immediately after it is discovered Guarantee claims are to be directed to the seller The seller must be informed before guarantee claims are processed For processing a guara...

Страница 18: ...5 C Load switch on 75 C Data on final charge voltage Depending on configured battery type Gel battery GEL Liquid electrolyte Li Normal charging float 13 9 V 27 8 V 13 9 V 27 8 V Boost charging boost f...

Страница 19: ...r segments 12 8 V 25 6 V 8 bar segments 12 7 V 25 4 V 7 bar segments 12 5 V 25 0 V 6 bar segments 12 0 V 24 0 V 5 bar segments 11 7 V 23 4 V 4 bar segments 11 1 V 22 2 V 3 bar segments 11 0 V 22 0 V 2...

Страница 20: ...739704...

Отзывы: