725.259 | Z04 | 2013-09-23
22
5 Operation
In parallel operation the power supply is regulated by the rotary switch on the
master, see the Steca Solarix PI operating instructions.
The rotary switches on the slaves have no function.
5.1 Rotary switch settings
Master
Slave(s)
Inverter state
Off
Off
Master and slaves switched off
Standby
Off
Load-dependent response of master and slaves, where
applicable
On
Off
Master always switched on, slaves switched on as
required
All On
Off
Master and slaves always switched on
This setting is recommended for high performance
devices (at the performance limit), e.g. for operating a
washing machine
6 Care, maintenance and service
The device is maintenance-free. If functional faults occur, please consult your
dealer and present the payment receipt/invoice.
X
Before cleaning, switch off all loads and switch off the master via the ro-
tary switch (setting "Off").
X
Regularly clean the outside of the casing with a damp cloth. Do not use
solvents.
EN