The Plumbing Instructions must be
given to the homeowner for future use.
Slope ceiling 2" per foot
A
⅜
" air gap is recommended below the
door and the door should incorporate a
splashguard. The top and sides of the
shower opening must be sealed.
⅜
" Shutoff Valve
Keep in open
position during
normal operation.
Steamhead Installation
Steamhead should be mounted
18" above the finished floor or
6" above the rim of the tub as
far from the bather as possible
.
½" x ½" x
⅜
" Tee.
Using existing Hot or
Cold water supply.
Union
Required
Safety Valve
Connect ¾" pipe to an
indirect waste or as
required by local codes.
WARNING:
If installing the
Steamist Unit in conjunction with
an acrylic modular tub/shower unit,
please consult the “manufacturer
of the module” for location of the
steamhead.
Steam Outlet Pipe -
Use a minimum of a ¾" Copper or Brass pipe.
CAUTION: Do NOT install a shutoff valve on the steam outlet pipe. Do NOT
create traps or valleys in this line which would prevent the flow of steam.The
steam outlet pipe should be pitched toward the Steam Generator (preferred),
allowing condensation to run back into the Steam Generator or toward the
steamhead.
If the steam pipe exceeds ten feet, use an appropriate pipe
insulation rated for a minimum of 212°F.
^
^
MENU
^^
^ ^
1
2
®
The TSC Control
MUST
be
installed inside (Required).
Plumbing Installation Instructions
Figure 4 - Typical Installation
Models: TSG-7 and TSG-10
02/09
Pub. No. 203-A
- 3 -
®