background image

Optional Auto

Drain Valve 

Model TSG-AD

Water Inlet

" Compression

Fitting

¾" Safety 

Relief Valve

¾" Steam

Outlet

Knockouts for

Electrical Supply Line

Knockout for
Control Cable

01/09

Pub. No. 204-A

- 1 -

Install Upright

and Level

®

C

US

®

 

WARNING:

 

Elderly persons, pregnant women, or those suffering from heart disease, high blood pressure, diabetes, or 

who are otherwise not in good health, do not use this device unless directed to do so by a physician. Also, do not use 
steambath while under the influence of alcohol.

!

IMPORTANT: The warranty of this product is voided if it is used in a commercial application or for anything other than a residential 
steambath installation. All electrical connections must be performed by a licensed electrician in accordance with Local and National 
Electric Codes.

Electrical Installation Instructions

Steambath Generators

Models: TSG-7 and TSG-10

The Steamist “TSG” Generator operates with a TSC control 
mounted inside and optional TSR remote control located outside 
the steamroom. It’s small enough in size to be tucked away using 
very little space in a vanity, closet, or basement, but large 
enough to provide steam for most residential baths.

The Steamist “TSG” Steambath Generator comes factory 
assembled, carefully wired and tested.

NOTE: The “TSG” Generators are designed only to work with 
the"TSC" Control.

1. 

Pre-Installation

a) Proper electrical supply (208 or 240 Volt): See rating 

label on Steam Generator and Chart on page 4. 
Determine proper size of wire, voltage, amperage, and 
phase for the Steam Generator. Only UL rated 90°C 
wire can be used.

b) In-line fuse/circuit breaker required: Fuse/circuit breaker 

to be installed must be sized in accordance with chart 
on back page. Do NOT install a GFI (Ground Fault 
Interrupter) to this equipment (per article 210-8 in the 
National Electric Code).

c) Route power supply cable to the location where the 

Steam Generator will be installed (before walls are 
closed).

2.

 Electrical Rough-in

a) Route appropriate power cable to the location the Steam 

Generator will be installed. If receptacle is desired, 
mount the box for the receptacle near the location of  
the Steam Generator (see Figure 3).

 

    NOTE: The plug and receptacle require a rating of no 

less than 250V and proper amperage. Refer to chart on 
page 4 for amperage rating.

 

    After the walls are complete, the Steam Generator and 

Control can be wired.

3.

 

Steam Generator Electrical Installation

 WARNING: 

All power to the Steam Generator must be  

 turned 

off. 

a) Remove the four screws holding the electrical access 

cover and remove cover.

b) Locate the supply line knockout. Mount proper strain 

relief into knockout hole.
c) Strip back power cable’s outer insulation jacket 

eight inches and insert into Steam Generator.  
Strip back insulation ½" from the three (3)     
incoming wires (two power and one ground). 

d) Insert ground wire into grounding lug located        

on the right side of the electrical compartment   
and secure.

 

CAUTION:  Be sure the ground wire does not 
come in contact with a live electrical part.

 

e) Locate the terminal block in the upper portion        

of the electrical box. Insert power wires into the 
power lugs on the right of the terminal block      
and secure.

4. 

Optional Auto Drain Valve Connection 

a) Open knockout for Auto Drain Valve conduit 

connection.

b) Route flexible conduit from valve to knockout and 

secure. 
c) Connect two wires from valve to the two place 
terminal strip provided (see Figure 2). 

Figure 1 - Steam Generator

 

 

®

Содержание TSG-10

Страница 1: ...ment near bath area The serial number plate should be visible and the Steam Generator should be accessible for service Refer to Installation Suggestions on page 4 Do NOT install Generator outdoors in a moist humid area or in an area where parts may freeze or corrode Also do NOT install near flammable materials such as paints thinners gasoline etc c The steam line and safety valve reach a temperatu...

Страница 2: ...f the escutcheon onto the steam pipe and screw the steamhead into place Care must be taken not to scratch the steamhead or escutcheon with wrench After the plumbing connections are complete the electrician may finish wiring the unit Figure 2 Plumbing Diagram Installation Instructions Models TSG 7 and TSG 10 02 09 Pub No 203 A 2 Apply a small amount of silicone to prevent movement Apply a small amo...

Страница 3: ...f installing the Steamist Unit in conjunction with an acrylic modular tub shower unit please consult the manufacturer of the module for location of the steamhead Steam Outlet Pipe Use a minimum of a Copper or Brass pipe CAUTION Do NOT install a shutoff valve on the steam outlet pipe Do NOT create traps or valleys in this line which would prevent the flow of steam The steam outlet pipe should be pi...

Страница 4: ...eam Generator CAUTION All models must be installed INDOORS in a DRY NON FREEZING location away from flammable materials such as Gasoline Paints Thinners Etc IMPORTANT Steam Generator must be installed upright and level Figure 5 Installation Suggestions Model No Max Cu Ft For Area Up To KW Volt Phase Amps Wire Size 90ºC Copper AWG Line Fuse Refer to the Steamist Sizing Guide for actual Cu Ft capaci...

Страница 5: ...se circuit breaker to be installed must be sized in accordance with chart on back page Do NOT install a GFI Ground Fault Interrupter to this equipment per article 210 8 in the National Electric Code c Route power supply cable to the location where the Steam Generator will be installed before walls are closed 2 Electrical Rough in a Route appropriate power cable to the location the Steam Generator ...

Страница 6: ...Before starting insure that the conditions of the following checklist have been met The proper size Steam Generator has been selected by using the sizing page in the Full Line Brochure Pricing Guide or The Generator Sizing Guide in the Residen tial Systems Steambath Product Information section of the Steamist website www steamist com CAUTION An improperly sized Steam Generator will NOT produce the...

Страница 7: ...nstallation Models TSG 7 and TSG 10 The TSC Control MUST be installed inside Required Inside Installation Control should be mounted four feet from the floor Select a location convenient to the bather but not in a direct line of Shower or Body sprays and not directly above the steam head ...

Страница 8: ...MP Wiring Diagram Models TSG 7 and TSG 10 L1 L2 Model No Max Cu Ft For Area Up To KW Volt Phase Amps Wire Size 90ºC Copper AWG Line Fuse TSG 7 220 7 5 240 208 1 1 31 36 8 8 40 50 Specification Chart TSG 10 375 10 240 208 1 1 42 48 6 6 60 60 1 2 3 4 5 6 7 8 Dip Switch Settings for Multiple Steam Generators on Processor Board Generator 1 1 and 2 up Generator 2 1 down and 2 up Generator 3 1 up and 2 ...

Страница 9: ...Steam Generators can be typically mounted within 25 ft of the bathing area Steam Generators should be accessible for service Do not install in attic Do not install generators outside in a moist humid area or in an area where parts may freeze or corrode Steamhead to be mounted 18 above floor or 6 above rim of tub and as far from the seating area as possible Rough in Notes Access 28 L x 18 W x 20 H ...

Страница 10: ...OINTING UP WARNING Unit must be installed INDOORS in a DRY NON FREEZING location and with arrows pointing up Service by authrorized personnel only NOTE Read all instructions before installation CAUTION To prevent internal damage hold all fittings securely while making plumbing connections NOTE See Wiring Diagram on reverse side of cover CAUTION Turn off electric before removing cover NOTE This is ...

Отзывы: