Caution:
We are not responsible for the malfunction and damage from
installation that
does
not comply to the
user manual.
Important:
Choosing a right location
Install an exhaust fan outside of the steam room
so
it can expel
the excessive steam from the shower room.
User Manual
Certified to CAN/CSA Std. No. 88
Conforms to UL. Std. 499
It is strongly recommended that the water intake solenoid be connected to a water supply using a braided hose line.
Teflon tape is required to make a liquid tight seal between the threads and a rubber gasket (washer) is used to seal
between the solenoid and the braided hose attachment. Incorporate thread sealant (teflon tape) on both the water intake
and drain solenoid for a tight seal to avoid leaks.
Technical Hotline 905-951-6662
1. Make surethe model and output are correct, including the voltage.
2. Make sure the power are matched with the steam room dimensions. Pay attention to the
steam room's cubic footage and wall finish materials. If you have any problems, please refer
page 11 for steam generator sizing and selection.
3. Read this entire manual before installation.
4. Saunacore will not be responsible for any damage or malfuntion due to the product by improper
installation.
5. Steamcore SpaII Series are pre-tested and inspected prior to packaging, please inspect package when received
to assure all is in proper condition. If you find any damage to the package, immediately put in a claim with the
delivering (courier) company for a claim of compensation.
6. The steam generator use in a heated indoor space only.
7. This unit must be completely installed with unions for easy removal, the steam lines must be 3/4" diameter
pipe for each steam line. Do NOT reduce steam line pipe diameter, do not connect steam lines, and a pressure
reducer valve must be used to reduce water pressure to 15-20 psi. Do NOT heat solenoids with any flame or
soldering torch.
Recommended installation locations.
1. The distance between the steam room and the steam generator should be 20ft or less. The steam generator is
supplied with a control cable of 20ft long. It can be extended if needed to a max of 60ft (with purchase of
additonal 20ft length control cables).
2. The steam generator should NOT be installed inside the steam room.
3. Do NOT install the steam generator outdoors or any place that will influence the operation, function, security
of the steam generator by the surrounding environment.
4. Do NOT expose generator to any place it may freeze, or near any combustible objects or chemicals.
5. Install steam generator in a dry well ventilated location.
NOTE: Do NOT apply any heat or source of flame to the intake/drain solenoids during installation. This can cause
damage or malfunction of components.
1