Steamaster Kanga 1200 Скачать руководство пользователя страница 14

28

Pressure limiting/adjusting valve

Mounted  as  standard  on  LW-K,  ZW-K, AX  and  available  as  optional  accessory  for  the  other 

models.

It is a valve that makes it possible to adjust the working pressure and that allows the pump fluid 
to  reflow  towards  the  by-pass  duct,  thus  avoiding  the  onset  of  dangerous  pressures,  when  you 
interrupt the flow rate or when you try to set pressure values above the maximum allowed ones.

D

CAUTION

v

The pressure limiting/adjusting valve is calibrated by the Producer or Builder of the machine
with the built-in pump

. Never operate on the pressure limiting/adjusting valve not to alter 

the calibration: operate on it only by using the knob (15).

2.3  IDENTIFICATION PLATE

D

CAUTION

v

If  during  the  use  the  identification  plate  is  worn,  apply  to  the  dealer  or  to  an  authorised
service centre to reset it.

The identification plate (7) contains the serial number and the pump model with a suitable code 
hinting  to  the  main  technical  features  of  the  pump  (see  also  the  paragraph  “FEATURES AND 
TECHNICAL DATA”).

3. INTENDED USE

D

CAUTION

v

The pump is only intended for pumping:
- high-pressure water in washing machines (water cleaners);
- water not for food use.

v

The pump is not intended for distributing:

non-filtered water or water with dirt;

  -  detergents, paints and chemical substances both in their pure state and in water solution;

sea water or high salt concentration water;

fuels and lubricants of any kind and type;

flammable fluids or liquefied gases;

food liquids;

water with temperature higher than 60°C or lower than 5°C;

v

The pump must be never used to wash: persons, animals, electrical devices under voltage,
delicate objects, the pump itself or the machine it is part of.

v

The accessories (standard and optional) and the detergents used with the pump must be of the
type authorised by the Producer.

v

The pump is not suitable for the use in rooms that show particular conditions such as, for
instance, corrosive or explosive atmospheres.

v

For  the  use  on  vehicles,  boats  or  aircraft,  apply  to  the  technical  service  of  the  Producer
because some added prescription can be necessary.

Any other use is improper.
The Producer cannot be hold liable for possible damage resulting from unintended or wrong uses.

4. OPERATION

4.1 PRELIMINARY ACTIVITIES

D

CAUTION

v

The pump cannot be commissioned if the machine on which it is built-in does not conform 
with  the  safety  requirements  established  by  the  European  Directives.  This  conformity  is 

Содержание Kanga 1200

Страница 1: ...5 Steamaster 6ReservoirAvenueGreenacreSydneyNSW2190Australia Tel 1300855677 Tel 61297963433 Fax 61297963395 www steamaster com au...

Страница 2: ...Steamaster 6ReservoirAvenueGreenacreSydneyNSW2190Australia Tel 1300855677 Tel 61297963433 Fax 61297963395 www steamaster com au...

Страница 3: ...5 Steamaster 6ReservoirAvenueGreenacreSydneyNSW2190Australia Tel 1300855677 Tel 61297963433 Fax 61297963395 www steamaster com au...

Страница 4: ...Steamaster 6ReservoirAvenueGreenacreSydneyNSW2190Australia Tel 1300855677 Tel 61297963433 Fax 61297963395 www steamaster com au...

Страница 5: ...Steamaster 6ReservoirAvenueGreenacreSydneyNSW2190Australia Tel 1300855677 Tel 61297963433 Fax 61297963395 www steamaster com au...

Страница 6: ...Steamaster 6ReservoirAvenueGreenacreSydneyNSW2190Australia Tel 1300855677 Tel 61297963433 Fax 61297963395 www steamaster com au...

Страница 7: ...cking Head Ring 18 3 2520 S 3016 S 3020 S 3025 S 3513 S 3513 E 3517 S 3525 S 21 1241 0065 Guarnizione Tenuta Packing 15 3 2020 S 1241 0035 Guarnizione Tenuta Packing 18 3 2520 S 3016 S 3020 S 3025 S 3...

Страница 8: ...M6x20 4 53 3016 0014 Flangia Flange MEC 90 1 54 3607 0015 Vite Testa Esagonale Hexagonal Screw M8x20 4 55 0019 0075 Anello Tenuta Olio Oil Seal 35x62x7 1 56 3019 0004 Seeger Esterno Outer Seeger 35 1...

Страница 9: ...0 4 3 OPERATION WITH DETERGENT 31 5 STOPPING_____________________________________________________32 6 CLEANING AND DECOMMISSIONING MAINTENANCE___________32 6 1 CLEANING AND DECOMMISSIONING 32 6 2 ORDI...

Страница 10: ...ime we recommend to carefully read this manual and invite you to observe what described in it Special attention must be paid to the reading of the text parts marked by the symbol D CAUTION because the...

Страница 11: ...believes necessary to improve the product without being obliged to apply these changes on the previously produced devices delivered or being delivered What stated in this paragraph excludes any expre...

Страница 12: ...oC oF Max water pressure bar psi Max priming depth m ft Min water flow rate 0 28 0 62 0 32 0 08 0 28 0 62 0 32 0 08 0 50 1 1 0 56 0 15 0 50 1 1 0 56 0 15 0 97 2 14 1 09 0 29 0 16 0 35 0 18 0 05 PERFO...

Страница 13: ...termine the maximum pressure according to the following table Maximum pressure in bar last two figures x 6 9 Maximum pressure in psi last two figures x 100 For instance TW 10522 22 x 6 9 151 8 bar LW...

Страница 14: ...ing machines water cleaners water not for food use v The pump is not intended for distributing non filtered water or water with dirt detergents paints and chemical substances both in their pure state...

Страница 15: ...p v Carry out the scheduled checks of the ordinary maintenance with special reference to the ones relating to oil b Replace the oil plug without vent 17 with the oil plug with vent 8 This operation co...

Страница 16: ...ks etc v Observe the safety instructions contained in the use and maintenance manual of the possible optional accessories that are used v Carry out the operations concerning commissioning recommended...

Страница 17: ...can be obtained by operating on the knob 15 by rotating it in clockwise direction the pressure increases and by rotating it in counter clockwise direction it decreases D CAUTION v Never operate on th...

Страница 18: ...STOPPING D CAUTION v Carry out the operations relating to stopping recommended by the producer of the machine with the built in pump No part of the pump must be moving and no pipe must have fluid und...

Страница 19: ...d not dispersed in the environment NOTE After a long pause of use a slight water dripping under the pump can take place This dropping disappears normally after some working hours If it persists apply...

Страница 20: ...500 hours 200 hours for AX Oil change 1 Check the delivery suction valves Check of pump screw tightening Check of the maximum pressure limiting adjusting valve only LW K ZW K and AX 1 The first oil ch...

Страница 21: ...rate of the hydraulic network or the priming depth conform with what described in paragraph Features and technical data Have the pump be primed according to what described in paragraph Standard opera...

Страница 22: ...in pump must be built in order to guarantee the conformity with the safety requirements established by the European Directives This conformity is guaranteed by the presence of the CE marking and by t...

Страница 23: ...e shaft 18 mm Female shaft 20 mm Female shaft 28 mm Female shaft 1 1 8 Female shaft 25 mm Female shaft 1 Hydraulic motor LW LW K LWS LWS K LWR LWR K LWD LWD K FW FWS FWD ZWD ZW K ZWD K HW HWS HWD TWN...

Страница 24: ...ight and left side of the head 2 4 PRESSURE LIMITING ADJUSTING VALVE In the models where it is already built in LW K ZW K AX it is adjusted by the producer so that it reaches the maximum allowed press...

Страница 25: ...6 9 6 6 25 18 4 d Connecting rod screws if present 9 6 6 e Case cover screws 9 6 6 4 3 0 4 3 0 9 6 6 f PTO flange screws 9 6 6 25 18 4 25 18 4 25 18 4 g Pistons nuts 6 4 4 10 7 4 10 7 4 15 11 1 Loctit...

Страница 26: ...2 1 1 1 1 1 3 4 5 0 4 5 1 1 1 6 7 2 8 5 3 0 1 3 9 8 4 9 1 6 3 0 1 3 1 4 5 4 A Steamaster 6ReservoirAvenueGreenacreSydneyNSW2190Australia Tel 1300855677 Tel 61297963433 Fax 61297963395 www steamaster...

Страница 27: ...B Steamaster 6ReservoirAvenueGreenacreSydneyNSW2190Australia Tel 1300855677 Tel 61297963433 Fax 61297963395 www steamaster com au...

Страница 28: ...C Steamaster 6ReservoirAvenueGreenacreSydneyNSW2190Australia Tel 1300855677 Tel 61297963433 Fax 61297963395 www steamaster com au...

Страница 29: ...D Steamaster 6ReservoirAvenueGreenacreSydneyNSW2190Australia Tel 1300855677 Tel 61297963433 Fax 61297963395 www steamaster com au...

Отзывы: