Page
8
Installation Procedures:
Warning: When installing jet massage baths, air massage baths, or dual baths, basic
precautions should be followed, including:
Danger: Risk of electrical shock. Connect only to a separate circuit protected by a
group fault circuit interrupter (GFCI)
Installation must provide access for servicing pump/motor (all tubs come with an
access panel for the pump/motor and faucet).
1.
Install tub waste/overflow according to instructions provided with fitting.
2.
Install faucet. If spout and supply lines are to be installed on deck of tub, mark the
locations and drill pilot holes from acrylic side of product.
Note: It is best to position the diverter directly over the overflow for easy
installation. The sequence would be: handle, handle, diverter, spout and then
handheld.
3.
Standard installation – After framing is complete (see attached diagrams), set product
in place to check fit and make certain that the tub can be properly leveled. (Caution:
if walk-in bathtub is not resting on all five leveling feet, water will not drain properly
and may cause the door to leak).
4.
Verify the product is completely level by checking tub deck surface and ensure all 5
leveling feet are touching the ground.
5.
Electrical connection is made by simply plugging pump cord (shipped with cord and
plug) into specified dedicated 120V, 30A, GFCI outlet.
6.
After plumbing and electrical connections have been made the tub should be cleaned
of dirt and debris.
7.
Installation is not complete until the bath has been water tested in place.
Содержание MG-304
Страница 1: ...Page 1 Installation and Operation Manual MG 305 120V 30a Please read this manual carefully before use ...
Страница 5: ...Page 5 ...
Страница 6: ...Page 6 ...