Important Safety Instructions: 

 

Warning! 

 

Use this unit only for its intended purposes or as described in this manual.   Use 
only attachments recommended by the manufacturer. 

 

Risk of hyperthermia and possible drawing.  Water temperature in excess of 38°C 
may be injurious to your health.  Check and adjust temperature before use.  

 

 

Read and Follow all Instructions 

 

Danger: To reduce the risk of injury, do not permit children or persons with 
infirmities to use this product unless they are closely supervised at all times. 

 

To avoid injury, exercise care when entering or exiting the walk-in tub. 

 

Never drop or insert any objects into any openings. 

 

Risk of electrical shock; connected only to a separate circuit protected by a ground 
fault circuit interrupter (GFCI). 

 

Warning: Risk of electric shock; do not permit electric appliances (such as a hair 
dryer, lamp, telephone, radio, or television) within 1.5M of this hydro-massage 
bathtub. 

 

The unit must be connected to a circuit interrupter (GFCI). Such a circuit is provided 
by the installer and should be tested on a routine basis.  To test the GFCI push the 
test button; the GFCI should interrupt power.  Push the RESET button; power should 
be restored.  If the GFCI fails to operate in this manner, there is a ground current 
flowing, indicating the possibility on an electrical shock.  Do not use this unit.  
Disconnect the unit and have the problem corrected by a qualified services 
representative before using.   

 

Traction enhanced-textured tub bottom must remain clean to minimize slippage. 

 

Risk of electrical shock; all pumps must be connected to a ground fault circuit 
interrupter (GFCI) protected outlets. 

 

Avoid use of alcohol, drugs, or medication while using your walk-in tub. 

 

Consult your physician before using the whirlpool/air system if you are pregnant 
and/or have heart conditions. 

 

All units must be water tested before installation.

Содержание MG-304

Страница 1: ...Page 1 Installation and Operation Manual MG 305 120V 30a Please read this manual carefully before use ...

Страница 2: ... a hair dryer lamp telephone radio or television within 1 5M of this hydro massage bathtub The unit must be connected to a circuit interrupter GFCI Such a circuit is provided by the installer and should be tested on a routine basis To test the GFCI push the test button the GFCI should interrupt power Push the RESET button power should be restored If the GFCI fails to operate in this manner there i...

Страница 3: ...and mishandling may cause leaks It is necessary to test the bath while there is access to all sides of the bath 2 This unit should be both static and operationally tested with water It is best to test the unit outside by filling with a garden hose a Place the tub on a completely flat surface in an area where it may be drained after testing b Seal the drain can be sealed with tape for test and fill...

Страница 4: ...ptional heater is present check the indicator light on the heater to insure that power is present Do not run any pumps or heaters unless the tub is filled with water to proper level Damage due to dry running pumps is not coved under 3 year warranty Failure to perform these tests before installation will make the installer liable for future repair costs ...

Страница 5: ...Page 5 ...

Страница 6: ...Page 6 ...

Страница 7: ...ec sheets attached to your unit 3 Insure that the proper electrical service has been installed at the pump location See electrical requirements below Electrical Requirements Equipment utilized on these baths requires individual dedicated electrical service for each product Each service must be a dedicated 30 amp 120 volt service that is GFCI protected 1 Hydro Jet Massage Systems require one 5 5 6 ...

Страница 8: ...iverter directly over the overflow for easy installation The sequence would be handle handle diverter spout and then handheld 3 Standard installation After framing is complete see attached diagrams set product in place to check fit and make certain that the tub can be properly leveled Caution if walk in bathtub is not resting on all five leveling feet water will not drain properly and may cause th...

Страница 9: ...turn on when the whirlpool is turned on The heater is designed to maintain the water temperature longer 5 If any factory installed fittings are removed do not operate the unit A safety hazard may be present 6 Do not use bubble bath when any pumps are operating 7 Bath oils may be used however their frequent use will require more frequent cleaning of the systems 8 Both air and whirlpool systems are ...

Страница 10: ...n between the air pipe and air switch Reconnect both parts Pump doesn t work No power Check the wiring Abnormal voltage Check the voltage and use adapted transformer Air is not switched on Check or charge the air switch Water Jet strength is not adjusting Suctions stopped Clean suction Massage bathtub is not leveled Leveling feet are not adjusted Adjust the leveling feet Poor seal ring Reinstall o...

Страница 11: ... Cover Clean and remove any hair or lint from the suction cover Monthly unscrew the suction cover and clean away hair lint or debris from the cover and housing then remount the cover in place Never operate the unit with the safety suction over off Do not use abrasive cleaners as they will scratch and dull the surface of the acrylic Plaster can be removed using a wooden stick DO NOT use a metal scr...