S/N
PROBLEM REASON
SOLUTION
Breaker damaged
Change breaker
The breaker is closed but the
1
power light is not lit
Fuse damaged
Change fuse
Check power input
Try another power input
2 After welding the machine is
Fan damaged
Change fan
over heated and fan does not
work
Cable is loose
Tighten cable
No gas in the gas cylinder
Change gas cylinder
Gas pipe leaks gas
Change gas pipe
3
Electromagnetic valve damaged Change valve
Control switch damaged
Change switch
Control circuit board damaged Change circuit board
STEALTH DIGI-MIG 200
23
DATE
MAINTENANCE CHECKS
Monthly
Use dry compressed air to clear the inside of arc welding machine. Pay
examination particular attention to clear any dust on radiator, main voltage transformer,
inductance, IGBT module, the fast recover diode and PCB, etc.
Check the arc welding machine bolt. If loose, tighten. Replace if worn. Scrape
off any rust to ensure it works efficiently.
Quarterly
Check the actual current accords with the displaying value. If not, they should
examination be reconfigured. The actual current value can be measured by the adjusted
plier-type ampere meter.
Annual
Measure the insulating impedance among the main circuit, PCB and case.
examination If it is below 1M
Ω
, insulation may be damaged and should be repaired or
replaced.
5.2 Troubleshooting
• Before arc welding machines are dispatched from the factory, they have already been
carefully checked. Do not allow anyone unauthorised to make any alterations to the
equipment.
• Maintenance work must be carefully undertaken. If any wire becomes loose or
misplaced, it may be a potential danger to the user.
• Only authorised professional maintenance personnel should overhaul the machine.
• Ensure the arc welding machine’s power is switched off before the mains power to
the machine is switched on.
• If any problems persist contact an authorised professional or your supplier.
Gun switch
pressed but
no shielded
gas output
No output
gas when
tested
Gas output
when tested
Содержание 9000H
Страница 1: ...Part No 9000H DIGI MIG 200 OPERATOR S MANUAL...
Страница 10: ...STEALTH DIGI MIG 200 10 2 5 Principles of welding 9 0 600 Io A 2 4Principles of welding...
Страница 26: ...STEALTH DIGI MIG 200 26...
Страница 27: ...STEALTH DIGI MIG 200 27...
Страница 28: ......