background image

english

25

25

•  Be alert to that, when welding a ceiling, floor, wall or any kind 

of separation, heat may cause fire at the hidden part which 

cannot be seen.

•  Do not weld within closed receptacles such as tanks or drums 

or  piping  unless  they  have  been  prepared  appropriately  in 

accordance with AWS F4.1.

•  Do not weld where the atmosphere might contain inflammable 

dust, gas or vapors from liquids (such as gasoline).

•  Connect the work cable to the work area as near as possible 

to  the  place  where  you  will  be  welding,  in  order  to  prevent 

welding current from long possibly traveling through unknown 

parts causing electrical shock, sparks and fire hazard.

•  Do not use welding to deice frozen pipes.

•  Remove  the  electrode  from  the  electrode  carrier  or  cut  the 

welding wire close to the contact pipe when you are not using it.

•  Use  protective  clothing  without  oil,  such  as  leather  gloves, 

heavy  shirt,  closed  trousers  without  patches,  high  shoes  or 

boots and a cap.

•  Keep any fuel as butane lighters or matches away from you, 

before starting to weld.

•  After completing work, inspect area to make sure that it is free 

of sparks, embers and flames.

•  Only use correct fuses or circuit breakers. Do not put ones of 

larger size or pass them by one side.

•  Follow the regulations in OSHA 1910.252(a) (2) (iv) and NFPA 

51B for hot work and have a person near to take care of fire 

and an extinguisher.

FLYING METAL OR SLAG may injure eyes.

•  Welding,  grinding,  wire  brushing  or  polishing  may  produce 

sparks or flying metal. When welds are cooling down they may 

release slag.

•  Use  authorized  safety  goggles  with  lateral  guards  down  to 

underneath your mask.

GAS ACCUMULATION may make you sick OR KILL YOU.

•  Close shielding gas when not using it.

•  Always give ventilation to closed spaces, or use an authorized 

respirator that replaces air.

MAGNETIC FIELDS may affect implanted medical devices.

•  Persons  using  pace  makers  or  other  implanted  medical 

devices must stay away.

•  Persons  using  implanted  medical  devices  must  consult 

their  doctor  and  the  manufacturer  of  the  apparatus  before 

approaching  arc  welding,  point  welding,  slotting,  plasma 

cutting, or induction heating operations. 

NOISE may injure your ear.

•  The noise of some processes or equipment may harm your 

ear. Use authorized ear protection when the level of noise is 

very high or above 75 dBa. 

THE CYLINDERS may burst when they have failures.

Cylinders containing shielding gas contain that gas under high 

pressure. The cylinders may burst when they have failures. As 

the  cylinders  are  usually  part  of  the  welding  process,  always 

treat them with care.

•  Protect  pressurized  gas-containing  cylinders  from  excessive 

heat,  mechanical  impacts,  physical  damage,  slag,  flames, 

sparks and arcs.

•  Install and secure the cylinders in a vertical position securing 

them  to  a  stationary  support  or  a  cylinder  holder  to  prevent 

them from falling down or falling over. 

•  Keep cylinders far away from electric or welding circuits.

•  Never wrap the welding torch about a gas cylinder.

 

•  Never allow an electrode to contact any cylinder.

•  Never weld on a pressurized cylinder; there will be an explosion.

•  Use correct shielding gas only, as well as regulators, hoses 

and connections designed for the specific application; maintain 

them, the same as the parts, in a good condition.

•  Always keep your face away from a valve outlet except when 

operating the cylinder valve.

•  Keep the protective cover in place over the valve except when 

the cylinder is in use or connected for being used.

•  Use the correct equipment, correct procedures and a sufficient 

number of persons to lift and move the cylinders.

•  Read  and  follow  the  instructions  regarding  compressed  gas 

cylinders,  associated  equipment  and  the  publication  of  the 

Compressed  Gas  Association  (CGP)  P-1  as  well  as  local 

regulations.

FIRE OR EXPLOSION hazard.

•  Do not place the unit on, over or close to combustible surfaces.

•  Do not install the unit close to inflammable articles.

 

•  Do not overcharge your building’s wiring – make sure that your 

power supply system is suitable in size, capacity and protected 

to comply with the requirements of this unit.

A DOWN-FALLING UNIT may cause injuries.

•  With heavy equipment, do use the lifting eye only for lifting the 

unit, NOT the wheel train, gas cylinders or other accessories.

•  Use equipment having a suitable capacity to lift the unit.

•  When using a fork lift, make sure that the tines of the fork lift are 

sufficiently long to extend beyond the opposite side of the unit.

OVERUSE may cause OVERHEATING OF THE EQUIPMENT.

•  Allow for a cooling period, follow the nominal working cycle. 

•  Reduce the working cycle or current before welding again.

•  Do not block or filter the airflow to the unit.

Содержание PLASMA120TGE

Страница 1: ...erating instructions P Manual de instru es rea Empresarial Andaluc a Sector 1 C Sierra de Cazorla 7 28320 Pinto Madrid SPAIN Email sales grupostayer com Email info grupostayer com Gama PLASMA P35 25C...

Страница 2: ...espa ol 2 2 FIG 1 4P35 25C PLASMA 25 GE FIG 2 4P60 80 PLASMA 80 T GE P60 120 PLASMA 120 T GE 1 5 2 3 4 6 1 2 3 4 5 6 7 8 9 10 12 11 14 13 20 19...

Страница 3: ...espa ol 3 3 FIG 3 4P60 40B PLASMA 40 GE 12 7 8 9 10 11 2 3 5 6 1...

Страница 4: ...O DI CONTROLLO CONTROL PANEL PAINEL DE CONTROLO P35 25C PLASMA 25 GE FIG 5 4PANEL DE CONTROL PANNELLO DI CONTROLLO CONTROL PANEL PAINEL DE CONTROLO P60 40B PLASMA 40 GE P60 80 PLASMA 80 T GE P60 120 P...

Страница 5: ...espa ol 5 5 FIG 6 4ANTORCHA TORCIA TORCH TOCHA Plasma TRAFIMET S25K FIG 8 4ANTORCHA TORCIA TORCH TOCHA Plasma TRAFIMET S105K FIG 7 4ANTORCHA TORCIA TORCH TOCHA Plasma TRAFIMET S45K...

Страница 6: ...guera aire Manicotto aria Air hose Mangueira ar Interna Interna Internal Interna 3m 3m 3m Cable masa con pinza Cavo massa con pinza Ground cable with clamp Cabo massa com pin a 3m 3m 3m 3m Cable alime...

Страница 7: ...factor de marcha del 60 Pos 13c Valor de la tensi n con factor de marcha del 100 Pos 14 S mbolos para la alimentaci n Pos 15 Valor nominal de la tensi n de alimentaci n Pos 16 M xima corriente de alim...

Страница 8: ...ldar y ropa para prevenir quemaduras 4HUMO y GASES pueden ser peligrosos El soldar produce humo y gases Respirando estos humos y ga ses pueden ser peligrosos a su salud Mantenga su cabeza fuera del hu...

Страница 9: ...ctivo cuando no lo use Siempre de ventilaci n a espacios cerrados o use un respira dor aprobado que reemplaza el aire 4 Los CAMPOS MAGN TICOS pueden afectar aparatos m dicos implantados Personas que u...

Страница 10: ...a de tener un electricista capacita do que pronto corrija cualquier problema causado por la insta laci n Asegure que la instalaci n recibe chequeo y mantenimiento regular Mantenga las puertas y panele...

Страница 11: ...mayores El equipo est preparado para trabajar en el rango de tempera turas de 15 C a 70 C teniendo en cuenta la limitaci n de la ba jada del rendimiento factor de marcha a partir de temperaturas ambie...

Страница 12: ...on electricista profesional en caso de duda USO DEL PLASMA 4Tercer paso CORTAR CONEXI N DE ANTORCHA Y PINZA DE MASA Conexi n modelos P35 25C PLASMA25GE y P60 40B PLAS MA40GE Estos modelos traen ya con...

Страница 13: ...e para cortes de metal al en cenderla podr proceder a cortar el material deseado Antes de empezar aseg rese de leer comprender y aplicar las instrucciones de seguridad y resto de instrucciones incluid...

Страница 14: ...mativa 6 1 Caracter sticas T cnicas Entrada de tensi n Entrada de corriente Ciclo de trabajo Capacidad de corte Peso Potencia del Generador 6 2 Declaraci n de conformidad Declaramos bajo nuestra exclu...

Страница 15: ...12a Valore della corrente per fattore di marcia de 45 Pos 12b Valore della corrente per fattore di marcia del 60 Pos 12c Valore della corrente per fattore di marcia del 100 Pos 13 Tensione in carica...

Страница 16: ...olo di lavoro il pi vicino possibile dalla saldatura Metta via o isoli la pinza a terra quando la medesima non sia collegata al pezzo di lavoro per evitare il contatto con nessun metallo o con qualsia...

Страница 17: ...ale come accenditori di butano o ceneri prima di cominciare la saldatura Dopo aver completato il lavoro ispezioni l area per assicurarsi che sia libera da scintille braci e fiamme Utilizzi soltanto i...

Страница 18: ...ani da tutte le parti in movimento tali come i ventilatori Mantenga tutte le porte pannelli coperchi e protettori chiusi en le loro posto Ottenga che solo le persone qualificate muovano porte pannelli...

Страница 19: ...allazione generale 2 Fissi la pinza di massa al materiale da tagliare 3 Colleghi l alimentatore della corrente 4 Prema l interruttore ON OFF per cominciare il lavoro MESSA IN SERVIZIO P60 40B PLASMA 4...

Страница 20: ...le attrezzature trifasiche non utilizzano neutro Si deve tenere sotto conto che se non si provvede sufficiente potenza il Plasma funzioner in modo corretto ma con la limitazione di che non potr taglia...

Страница 21: ...SMA120TGE P60 120 PLASMA120TGE 38 mm 35 mm P60 120 PLASMA120TGE P60 120 PLASMA120TGE P60 120 PLASMA120TGE 5 Istruzioni di manutenzione e servizio 5 1 Pulizia manutenzione lubrificazione affilati Per p...

Страница 22: ...neratore 6 2 Dichiarazione di conformit Dichiariamo sotto la nostra esclusiva responsabilit che le macchine FONTI DI POTENZA PER SALDATURA modelli soddisfano tutti i requisiti essenziali di sicurezza...

Страница 23: ...uty cycle Pos 13c Load tension for 100 duty cycle Pos 14 Symbol for power supply Pos 15 Nominal value of supply tension Pos 16 Maximum nominal supply current Pos 17 Maximum effective supply current Po...

Страница 24: ...n smoke When you are indoors ventilate the area and or use forced local ventilation in front of the arc to remove welding smoke and gases When ventilation is bad use an authorized respirator Read and...

Страница 25: ...e authorized ear protection when the level of noise is very high or above 75 dBa THE CYLINDERS may burst when they have failures Cylinders containing shielding gas contain that gas under high pressure...

Страница 26: ...welding machine use shielded cables use line filters or shield the work area in one way or another 2 3 Reducing electromagnetic fields To reduce magnetic fields EMF in the work area the following proc...

Страница 27: ...trigger fig 3 you must select button 10 and observe that led 3 lights up P60 40B PLASMA40GE 15 To work with 4T continuous action of the trigger fig 2 you must select button 10 and observe that led 2...

Страница 28: ...or front analogue button 2 You may check air discharge by pushing purge button 7 For cutting pull trigger 17 when necessary unlock it with pin 16 and point the torch 15 towards the workpiece Depending...

Страница 29: ...he technical service will advise you on questions you might have regarding the repair and maintenance of your product as well as on spare parts You may obtain exploded drawings and information on spar...

Страница 30: ...alor da corrente para fator de opera o ao 45 Pos 12b Valor da corrente para fator de opera o ao 60 Pos 12c Valor da corrente para fator de opera o ao 100 Pos 13 Tens o em carga U2 Pos 13a Valor da ten...

Страница 31: ...enhum metal ou algum objeto que esteja aterrizado Isole a abra adeira de terra quando n o esteja conectada pe a de trabalho para evitar que contacte com qualquer objeto de metal PARTES QUENTES podem c...

Страница 32: ...regulamentos em OSHA 1910 252 a 2 iv e NFPA51B para trabalho quente e tenha uma persona para cuidar fogos e um extintor perto O METAL OU ESCORIA QUE VOA pode lesionar os olhos O soldar picar escovar...

Страница 33: ...s tampas ou resguardos quando acabe de se dar manuten o e antes de conectar novamente a pot ncia de entrada A RADIA O de ALTA FREQU NCIA pode causar interfer ncia A radia o de alta frequ ncia H F em i...

Страница 34: ...14 Conector de gatilho pistola 15 Corpo tocha plasma 16 Mecanismo de seguran a do gatilho 17 Gatilho ON OFF de tocha 18 Cabo alimenta o do equipamento 19 Conjunto ventilador grelha prote o 20 Regulad...

Страница 35: ...hem corretamente A pot ncia m nima a fornece ao Plasma MODELO VOLTAGEM PO T NCIA M XIMA KVA POT NCIA RECOMEN DADA KVA Amperagem e voltagem para Interruptores magnetot rmicos e diferenciais P35 25C PLA...

Страница 36: ...s instru es de seguran a e resto de instru es inclu das neste presente manual A seguir vai encontrar uma s rie de indica es gerais que lhe permitem iniciar se no mundo da soldadura e come ar a trabalh...

Страница 37: ...idas a uma reciclagem ecol gica Reservado o direito de modifica o 6 Normativa 6 1 Caracter sticas T cnicas Entrada de tens o A Entrada de corrente ON OFF EN60974 Ciclo de trabalho Capacidade de corte...

Страница 38: ...NOTAS 38...

Страница 39: ...rea Empresarial Andaluc a Sector 1 C Sierra de Cazorla 7 28320 Pinto Madrid SPAIN Email sales grupostayer com Email info grupostayer com...

Страница 40: ...www grupostayer com rea Empresarial Andaluc a Sector 1 C Sierra de Cazorla 7 28320 Pinto Madrid SPAIN Email sales grupostayer com Email info grupostayer com...

Отзывы: