![Status Pro BG 840100 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/status-pro/bg-840100/bg-840100_user-manual_1367493015.webp)
4.5 Use the Store Function of the Level Meter
1. When use the store function of the level meter, please insert the plug of the control
box into the data transmission socket of the Digital E-level meter.
2. At the measuring phase
and
, after the shown measuring
data is steady, press the count button “Save” on the control
box, the present data is stored in the instrument, the sequence
number for the stored data is also shown. If want to cancel the
stored measuring data, press the cancel button “Delete” on the
control box, then the cancellation will begin from the latest stored data in turn.
3. The digital E-level meter could store maximum 500 data. The unit will be base on the
one of the first stored data. Two kinds of measuring units could not be stored at same
time in case something wrong happen at the application software when output.
Reminding
➜
When use store function in the measurement, measuring data for several
inspected work pieces could be stored. When connect with the measuring soft-
ware of computer, the sequence of data reading need to be noticed in case of
confusion.
4.6 Measurement Connecting with Computer
Connecting method
–
Collect data directly (transfer the reading of E-level meter directly to software).
–
Read data in batch ( E-level meter could store 500 measuring data).
Interface Standard
Standard RS232 interface
Data format
Store the data in format of text, MS-EXCEL format.
Data processing
For flatness, straightness inspection and data
process, please reference to the Software
Operation Instruction.
15
OPERATION GUIDE
Status
Pro
–