33
Complaint
Cause
remedy
user
Qualified serViCe agenCy
*Water not hot enough
Thermostat set too low.
Set thermostat dial to a higher
temperature
Upper and/or lower temperature
probe out of calibration.
Call qualified service agency
Check continuity and resistance (Ohms)
of upper and lower temperature probes.
replace probes if out of specification.
*Insufficient hot water
*See WATer TeMPerATUre
CONTrOl WArNING (on page
12).
Thermostat set too low.
Set thermostat dial to a higher
temperature
Upper and/or lower temperature
probe out of calibration.
Call qualified service agency
Check continuity and resistance (Ohms)
of upper and lower temperature probes.
replace probes if out of specification.
Main manual gas shutoff valve
partially closed.
Open main manual gas shutoff
valve to fullest extent.
Heater too small for demand.
Space usage to give heater time
to restore water temperature.
Heater recovery is slower.
Call qualified service agency
Check gas input. If incorrect, check
for inlet air blockage and/or flue gas
exhaust blockage.
Water temperature too hot.
Thermostat set too high.
Set thermostat to a lower setting.
rumbling.
Sediment accumulation on
bottom of tank.
Drain a quantity of water through
drain valve. If rumbling persists,
call a qualified service agency.
Delime heater.
Ticking or metallic sounds.
expansion and contraction -
normal.
Pounding or water hammer.
Air chambers in piping have
become waterlogged. Thermal
expansion tank damaged,
improperly charged, or
improperly sized.
Drain piping system and refill.
Heater must be off while this
is being done. Check thermal
expansion tank charge pressure
when the water system pressure
is zero.
Follow the manufacturer's instructions
for proper charging of the thermal
expansion tank.
Water leaks.
Drain valve not closed tightly.
If drain valve cannot be closed
tightly, replace.
If leakage source cannot be
corrected or identified, call
qualified service agency.
Shut off gas supply to heater
and close cold water inlet valve
to heater.
repair or in case of suspected tank
leakage, be certain to confirm before
replacing heater.
Gas odors.
Possible gas leaks.
Shut off gas supply to heater
and call gas company at once
trouBleshooting
Содержание SBL81120NE
Страница 49: ...49 Model Dimension A SBL 120 154 68 SBL 180 199 250 A 76...
Страница 50: ...50 Notes...