Servicing should only be performed by a Qualified Service Technician

EFFIKAL RVGP-KSF-SERIES FLUE DAMPER TROUBLESHOOTING GUIDE

Do not turn damper open manually or motor damage will result, use the service switch. All readings are taken 

from harness receptacle. Do not push meter leads into harness receptacle. This opens the pins and will 

create connection problems. 

PIN END VIEW

NOTE: DAMPER DISC SHOWN IN OPEN POSITION.

Effikal Pinouts 

 

Adapter wire

& wire colors 

Function 

colors in*

1. Brown 

24 VAC HOT 

Black

2. Orange 

Signal In 

Yellow

3. Yellow 

Signal Out 

Red

4. Black 

24 VAC Common 

White

 

 

 

 

24 VAC. 

NORMAL SEQUENCE OF OPERATION 

     

B. DAMPER HAS OPENED, 

  NO COMBUSTION

  VOLTAGE ACROSS:

  4 & 1; 4 & 2; 4 & 3: 

1. Check for power at ignition module terminals.  If 24 VAC power is present damper

 

   

    is working properly. 

 

 

   

2. Defective component in water heater after the flue damper. 

 

   

3. If 24 VAC is not present at the ignition module, look for  loose or broken 

        

  connections between damper and ignition module.

   

4.  If the connections from damper to ignition module seem  proper, replace damper    

   

  assembly. If a damper assembly  is not available, place the service switch in the 

 

   

  hold open  position. This  should keep the damper in the open position and allow 

 

   

  the customer to have automatic heat, until a replacement damper can be installed.

C. DAMPER ROTATES  

     CONTINUOUSLY 

Change the entire damper assembly

D. DAMPER STICKS 

1.  Make sure no screws obstruct the damper blade.

   

2.  Make sure damper pipe assembly is not egg shaped.

   

3.  Make sure damper rod is not rubbing on pipe assembly.  

        

  See figure on front page of this insert sheet

   

ABNORMAL OPERATION

A. NOTHING WORKING

  NO VOLTAGE ACROSS:

  4 & 1 

1. High Limit has tripped and is OPEN. Determine reason for tripping of high limit   

   

2. Bad Transformer

   

3. Loose or broken connections

   

4. Blown fuse or circuit breaker

   

5. Disconnect switch off

   

6. Harness not plugged into water heater receptacle

A. FLUE DAMPER OPEN OR OPENING

  (Unit is calling for heat and damper disc should be in vertical position)

  VOLTAGE ACROSS:

  4 & 1 

All Times that High Limit is closed 

  4 & 2 

Calling for Heat 

Open or Opening 

  4 & 3 

During Combustion 

Damper Open+

B.

 

FLUE DAMPER CLOSED (Unit is not calling for heat and damper disc should be in horizontal position)

  NOTE: POSITION 4 IS COMMON AND POSITION 3 IS HOT 24 VAC

  VOLTAGE ACROSS: 

  4 & 1 

All Times that High Limit is closed

  NO VOLTAGE ACROSS:

  4 & 3 or 4 & 2 

1.Thermostat not calling for heat. 

 

IMPORTANT: DAMPER MUST BE OPEN BEFORE COMBUSTION TAKES PLACE.  If all steps have 

been tried and damper problems persists, contact State Water Heaters (800) 365-8170.

 WARNING

Do not negate the action

of any existing safety

or operational controls.

Содержание SBD100390E

Страница 1: ...00278164_2000536778 FOR MODELS SBD71120 N P through SBD100390 N P E Series 118 119 INSTALLATION CONSIDERATIONS PRE SERVICE CHECKS CONSTRUCTION OPERATION SERVICE TROUBLESHOOTING SERVICING SHOULD ONLY B...

Страница 2: ...Ignition Control Ignition Module 12 SEQUENCE OF OPERATION FLOW CHART 13 TROUBLESHOOTING CHECKLIST 14 GENERAL SERVICE CHART 15 FAULT AND WARNING CODES 16 Step 1 Troubleshooting The Water Heaters 16 Fl...

Страница 3: ...ied as defined by ANSI above and licensed or certified as required by the authority having jurisdiction to perform a given task do not attempt to perform any of the procedures described in this servic...

Страница 4: ...al expansion can cause premature tank failure leakage This type of failure is not covered under the limited warranty Thermal expansion can also cause intermittent Temperature Pressure Relief Valve ope...

Страница 5: ...ional Fuel Gas Code ANSI Z223 1 and with the Category I Venting Tables If any part of the vent system is exposed to ambient temperatures below 40 F it must be insulated to prevent condensation Do not...

Страница 6: ...h power vent kits for sidewall venting State Water Heaters offers power vent kits for use on installations with a maximum of 100 equivalent feet of vent piping The power vent kits also use type B vent...

Страница 7: ...W C for natural gas and 11 0 W C for propane gas The minimum supply pressure is measured while gas is flowing dynamic pressure The supply pressure should never fall below 4 5 W C for natural gas and...

Страница 8: ...as lines or emergency malfunction of the supply system the gas valve must be checked for safe operation Make sure that the outside vents on the supply regulators and the safety vent valves are protect...

Страница 9: ...eak test before placing the water heater in operation Disconnect gas piping and main gas shutoff valve before leak testing Install sediment trap in accordance with NFPA 54 Use joint compound or Teflon...

Страница 10: ...OCANNON MAY HAVE 1 3 OR 7 CROSS TUBES AUTOMATIC FLUE DAMPER All units are equipped with an automatic flue damper that reduces heat loss during the OFF cycles The automatic flue damper drive assembly i...

Страница 11: ...must be in the ON position to perform ohm continuity tests ON OFF switch replaced the gas cock on this new valve design GAS PRESSURE SPECIFICATIONS MODELS NATURAL SBD 71120 100390 PROPANE SBD 71120 1...

Страница 12: ...ntrols would allow the gas control valve to remain open causing water temperature to exceed the thermostat setting The water temperature would continue to rise until high limit switch operation Contac...

Страница 13: ...g checklist should be examined to eliminate obvious problems from those requiring replacement or servicing Check that main manual gas shut off valve is fully open and that gas service has not been int...

Страница 14: ...13 Servicing should only be performed by a Qualified Service Technician SEQUENCE OF OPERATION FLOW CHART...

Страница 15: ...Condensation on outside of tank normal Rumbling Sediment accumulation on bottom of tank Drain a quantity of water through drain valve If rumbling persists call a qualified service agency Delime heate...

Страница 16: ...ANSION TANK FAULTY VALVE REPLACE RELIEF VALVE LARGE VOLUME WATER RELIEF FROM T P VALVE EXCESSIVE WATER TEMPERATURE CHECK WIRING REPLACE DUAL CONTROLLER FAULTY RELIEF VALVE REPLACE RELIEF VALVE PREMATU...

Страница 17: ...supplied to the heater Make sure the tank is full of water Make sure the gas is supplied to the unit EFFIKAL DAMPER The wiring colors from the damper PC Board are different colors than the wires on th...

Страница 18: ...r 3 Yellow White 24V Common 4 Black CONDITION Damper closed High Limit closed FLUE DAMPER Do not turn damper open manually or motor damage will result use the service switch All readings are taken fro...

Страница 19: ...w the customer to have automatic heat until a replacement damper can be installed C DAMPER ROTATES CONTINUOUSLY Change the entire damper assembly D DAMPER STICKS 1 Make sure no screws obstruct the dam...

Страница 20: ...AC is not present Check Wiring Harness to Thermostat 24VAC present Damper Opens Continue to Step 3 CONDITION Damper rotates continuously STEP 3 TEST THE THREE AMP FUSE CONDITION Test via the terminals...

Страница 21: ...s lights are not visible on the thermostat 24VAC out of the thermostat via the Yellow wire to ground is not present No Pilot or Main burner flame present Error indication LED light on the Honeywell mo...

Страница 22: ...TEP 5 WIRE HARNESS TEST CONDITION Damper Open no 24VAC to module 24VAC terminal Test for 24 VAC between terminal 24V on the IID module and 24V GND IF THEN 24VAC is present This is correct Continue to...

Страница 23: ...OT VALVE CONDITION 24VAC to module no pilot Using a multimeter test for 24 VAC between terminal PV and 24 V GND on the IID during the 90 second trial for ignition IF THEN The meter does not read 24 VA...

Страница 24: ...k for spark at the pilot assembly Note The pilot burner mounts on the left side of the main burner IF THEN The igniter is not sparking during the 90 second trial for ignition Check for A 7 64 spark ga...

Страница 25: ...ignal becomes a DC current that the module can interpret The pilot hood must be properly grounded and the pilot flame must remain in contact with both surfaces for the flame proving signal to remain c...

Страница 26: ...EST CONDITION Pilot Flame Noted No Sparking No Main Burner Using a multimeter test for 24 VAC between terminal MV on the IID and 24V GND IF THEN 24 VAC is not present Replace the IID module Check the...

Страница 27: ...chnician STEP 10 MAIN BURNER TEST CONDITION Pilot flame Noted Main burner Check Visually check for main burner IF THEN The main burner ignites Sequence is complete The main burner does not ignite Chec...

Страница 28: ...27 Servicing should only be performed by a Qualified Service Technician WIRING DIAGRAM 118 119 SERIES CONTROLS...

Страница 29: ...28 Servicing should only be performed by a Qualified Service Technician NOTES...

Страница 30: ...29 Servicing should only be performed by a Qualified Service Technician NOTES...

Страница 31: ...additional information contact State Water Heaters 500 Tennessee Waltz Parkway Ashland City TN 37015 Technical Support 800 365 8170 Parts 800 821 2017 www statewaterheaters com Copyright 2016 State In...

Отзывы: