IMPORTANT: VENTING AND COMBUSTION AIR REQUIREMENTS

Read and follow requirements shown in the Installation Manual for Select
Power Direct-Vent Gas water heaters dealing with type, placement and length
of vent pipe and vent termination, as well as clearances required to provide
adequate combustion air and proper ventilation.

E

C

4"

MODEL

PEAK

ENERGY

GAL.

BTU INPUT

RECOVERY

R

DIMENSIONS IN INCHES

APPROX.

NUMBER

DEMAND

FACTOR

CAP.

PER HOUR

90°F RISE

VALUE*

SHIPPING

OUTPUT

NATURAL†

GALLONS †

A

B

C

D

E

F

DRAFT

WEIGHT

(1st Hour

HOOD

(LBS.)

Rating

OUTLET

Gallons)

GS6 40 YBPDT

70

.60

40

40,000

41

16

57

48-1/2

21

15

8

42

3

224

GS6 50 YBPDT

87

.59

50

40,000

41

16

66

57-1/2

21

15

8

51

3

232

GS6 50 YRPDT 5

105

.58

50

65,000

64

16

69-1/2

61

21

15

8

54-1/2

3

232

GS6 75 YRPDT

130

.58

75

70,000

72

16

71-1/2

61-1/2

26-1/4

15-1/2

8

54-3/4

3

300

For model number GS6 50 YRPDT 5, 5’ of 3” ABS vent pipe is supplied and must be used for the first 5’ of the exhaust outlet vent system.

For model number GS6 75 YRPDT, 5’ of 3” CPVC vent pipe is supplied and must be used for the first 5’ of the exhaust outlet vent system.

Recoveries are rounded to nearest gallon

Water Connections – 3/4" on all models

When ordering Propane, change “

Y

” to “

H

” in model number (GS6 40

H

BPDT)

† Propane Gas Inputs/Recoveries –

GS6 40 HBPDT:

36,000 BTU / 37 GPH

GS6 50 HBPDT:

38,000 BTU / 39 GPH

GS6 50 HRPDT 5:

60,000 BTU / 59 GPH

GS6 75 HRPDT:

65,000 BTU / 67 GPH

*R Value shown is “Performance Rated ”

IMPORTANT:

SEE INSTALLATION MANUAL FOR COMBUSTION AIR AND VENTING SYSTEM

REQUIREMENTS FOR POWER DIRECT-VENT WATER HEATERS

OPTIONAL (DELUXE) ROUND HORIZONTAL

VENT TERMINATION KIT

Part Number 9002749

OPTIONAL (DELUXE) SQUARE HORIZONTAL

VENT TERMINATION KIT

Part Number 9003328

SELECT