![STARWELD QUATRO 450 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/starweld/quatro-450/quatro-450_operators-manual_1366761009.webp)
Starweld Quatro 450 Operato
r’s Manual
9
The Starweld Quatro 450 does not include a gas solenoid inside the unit, therefore a
TIG torch needs to be used with a gas valve built into it. The gas line from the torch
is then connected straight to the flowmeter on the gas cylinder.
3.8 Connecting Input Power
Turn off power before connecting unit to mains
Do not use worn, damaged, and undersized cables or plugs
The unit is supplied with usually a five meter trailing cable (other lengths are
available on request). If no plug is supplied with the unit then the connections are
the following:
Green/Yellow
-
Represents the earth wire
Brown
-
Represents Phase A
Blue
-
Represents Phase B
Black
-
Represents Phase C
The Quatro 450 is designed to work on a three phase with earth system only.