STARWELD QUATRO 450 Скачать руководство пользователя страница 3

 

Starweld Quatro 450 Operato

r’s Manual           

  3 

2  Safety 

 
Only qualified persons should install, operate, maintain, and repair this unit. 
 
During operation, keep everybody, especially children, away. 
 

 

Electrical Hazards 

 
Electric shock from welding can kill or cause severe burns. The electrode and work 
circuit is electrically energized whenever the output is on. The input power circuit 
and unit internal circuits are also electrically energized when the mains power is on. 
When MIG welding, the wire, drive rolls, and all other metal parts touching the wire 
are electrically energized. Incorrectly installed or improperly grounded equipment 
presents a shock hazard. 
 

  Read the instruction manual before installing, operating, or servicing the unit. 

  Have all installation, operation, maintenance, and repair work performed only 

by qualified people. 

  Do not touch live electrical parts. 

  Wear dry, insulating in good condition and protective clothing. 

 

Insulate yourself from the workpiece and ground by wearing rubber-soled 
shoes or standing on a dry insulated mat or platform.

 

 

Use fully insulated electrode holders. Never dip the holder in water to cool it 
or lay it on conductive surfaces or the work surface. Do not touch holders 
connected to two welding machines at the same time or touch other people 
with the holder or electrode.

 

 

Do not use worn, damaged, undersized, or poorly spliced cables, welding gun 
cables, and torch cables. Make sure all connections are tight, clean, and dry.

 

 

Do not wrap cables carrying welding current around your body.

 

 

In confined spaces or in electrically hazardous locations due to water or 
perspiration, do not use a welder with AC output unless it is equipped with a 
voltage reducer and remote output control. Use equipment with DC output.

 

 

Turn off all equipment when not in use. Disconnect the power to equipment if 
it will be left unattended or out of service.

 

 

Wear a safety harness to prevent falling in a potentially hazardous area.

 

 

Keep all covers secured in place.

 

 
Many welding processes produce fumes and gases, which may be harmful to your 
health. 
 

  Keep your head out of the fumes. Do not breathe the fumes. 

  If inside, use ventilation or an exhaust at the arc to remove welding fumes 

and gases. 

 

Welding Fumes and Gases 

Содержание QUATRO 450

Страница 1: ...IMPORTANT DO NOT INSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY SECTION CONTAINED INSIDE THIS MANUAL STARWELD WELDING SOLUTIONS WEBSITE www starweld co za TEL 27 1...

Страница 2: ...5 STICK WELD CONNECTION 8 3 6 MIG WELD CONNECTION 8 3 7 TIG WELD CONNECTION 8 3 8 CONNECTING INPUT POWER 9 4 Operation 10 4 1 CONNECTIONS 11 4 1 1 Power 11 4 1 2 Output Terminals 12 4 1 3 14 way Sock...

Страница 3: ...ng on a dry insulated mat or platform Use fully insulated electrode holders Never dip the holder in water to cool it or lay it on conductive surfaces or the work surface Do not touch holders connected...

Страница 4: ...ocesses produce molten metal sparks and hot work surfaces These can cause fire or explosion if precautionary measures are not followed Welding on closed containers can them to explode Check and make s...

Страница 5: ...metal Wear approved safety glasses with side shields even under the welding helmet Wear approved ear protection if noise level is too high Electric arc welding processes produce intense electric and...

Страница 6: ...tive Humidity Altitude Above Sea Level 10 C to 40 C 50 C to 80 C Up to 50 at 40 C Up to 90 at 20 C Up to 1800m 3 2 Duty Cycle Duty cycle is the percentage of ten minutes that the unit can weld at sele...

Страница 7: ...Starweld Quatro 450 Operator s Manual 7 15cm Unit Wall Front of Unit Figure 1 Location of Unit...

Страница 8: ...that is earth cable and electrode cable of 100m then the cable size should be 70mm2 3 5 Stick Weld Connection Stick welding requires positive polarity that is the electrode holder is connected to the...

Страница 9: ...ting Input Power Turn off power before connecting unit to mains Do not use worn damaged and undersized cables or plugs The unit is supplied with usually a five meter trailing cable other lengths are a...

Страница 10: ...anying LED indicates the selected mode LOCAL REMOTE BUTTON Used to select the input reference Either from the main encoder local or from a suitable remote controlling device When in the TIG and Stick...

Страница 11: ...ond time 4 The parameter in the Voltage Display will begin to flash indicating that this has been selected for change 5 Use the Encoder to now adjust this parameter 6 After the desired value is select...

Страница 12: ...3 14 way Socket The 14 way socket is used for the connection of torch triggers interconnection cables and ancillary equipment Pin Function 1 TIG Trigger 2 TIG Trigger 3 Pot GND 4 Pot Wiper 5 Pot 5V 6...

Страница 13: ...t voltage is applied and welding may continue as long as there is welding current and after an internally set time for tacking Thereafter the voltage is once more reduced The time that is allowed for...

Страница 14: ...d fan as well 6 2 Troubleshooting Fault Remedy Power LED does not light Switch the circuit breaker at the rear of the unit to the on position Switch the unit on at the wall plug Make sure the wall plu...

Страница 15: ...Starweld Quatro 450 Operator s Manual 15 7 Electrical Diagrams...

Страница 16: ...Starweld Quatro 450 Operator s Manual 16 8 Parts...

Страница 17: ...00VA Transformer 3 Circuit Breaker 4 HF Transformers 5 WM020 Power Board 6 Input Bridge 7 WM081 Soft Start 8 Output Diodes 9 LEM Module 10 Positive Socket 11 14 Way Socket 12 10A Circuit Breaker 13 WM...

Страница 18: ...excluding misuse and abuse The equipment must be returned to Arc Quip or its agents For service repairs and technical assistance contact your STARWELD dealer or the manufacturer Distributor Starweld...

Отзывы: