3  Installation 

 

3.1  Specifications 

 

Input 

Input Voltages 

Maximum Input Current 

380V 

43A 

Rated Output 

Duty Cycle 

Output Amperes 

Volts at Rated 
Output Amperes 

Input Amperes 
380V 

Stick    100% 

450A 

38V 

43A 

TIG      100% 

450A 

28V 

32A 

MIG     100% 

450A 

37.5V 

43A 

Output 

Output Current Range 

Open Circuit Voltage 

Type of Output 

15-450A 

55V 

DC 

Physical Dimensions 

Height 

Width 

Depth 

Weight 

370mm 

350mm 

500mm 

33kg 

Environmental 

Operating 
Temperature 
Range 

Storage 
Temperature 
Range 

Relative Humidity  Altitude Above 

Sea Level 

-10

C to +40

-50

C to +80

Up to 50% at 40

Up to 90% at 20

Up to 1800m 

 
 

3.2  Duty Cycle 

 
Duty cycle is the percentage of ten minutes that the unit can weld at selected current 
without overheating. 
 
If the unit was used at 450A (Maximum Current)  then the unit could weld 
continuously, that is no time is needed in order to let the unit cool. 
 

3.3  Selecting Location 

 
The air is blown from the rear of the unit through the heatsink and out the front of the 
unit, therefore adequate thought needs to be considered about the location of the 
unit. 
 
The unit should be spaced at least 15cm away from a wall at the rear of the 
machine, this will allow adequate airflow into the unit. 
 

Содержание QUATRO 450

Страница 1: ...IMPORTANT DO NOT INSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY SECTION CONTAINED INSIDE THIS MANUAL STARWELD WELDING SOLUTIONS WEBSITE www starweld co za TEL 27 1...

Страница 2: ...5 STICK WELD CONNECTION 8 3 6 MIG WELD CONNECTION 8 3 7 TIG WELD CONNECTION 8 3 8 CONNECTING INPUT POWER 9 4 Operation 10 4 1 CONNECTIONS 11 4 1 1 Power 11 4 1 2 Output Terminals 12 4 1 3 14 way Sock...

Страница 3: ...ng on a dry insulated mat or platform Use fully insulated electrode holders Never dip the holder in water to cool it or lay it on conductive surfaces or the work surface Do not touch holders connected...

Страница 4: ...ocesses produce molten metal sparks and hot work surfaces These can cause fire or explosion if precautionary measures are not followed Welding on closed containers can them to explode Check and make s...

Страница 5: ...metal Wear approved safety glasses with side shields even under the welding helmet Wear approved ear protection if noise level is too high Electric arc welding processes produce intense electric and...

Страница 6: ...tive Humidity Altitude Above Sea Level 10 C to 40 C 50 C to 80 C Up to 50 at 40 C Up to 90 at 20 C Up to 1800m 3 2 Duty Cycle Duty cycle is the percentage of ten minutes that the unit can weld at sele...

Страница 7: ...Starweld Quatro 450 Operator s Manual 7 15cm Unit Wall Front of Unit Figure 1 Location of Unit...

Страница 8: ...that is earth cable and electrode cable of 100m then the cable size should be 70mm2 3 5 Stick Weld Connection Stick welding requires positive polarity that is the electrode holder is connected to the...

Страница 9: ...ting Input Power Turn off power before connecting unit to mains Do not use worn damaged and undersized cables or plugs The unit is supplied with usually a five meter trailing cable other lengths are a...

Страница 10: ...anying LED indicates the selected mode LOCAL REMOTE BUTTON Used to select the input reference Either from the main encoder local or from a suitable remote controlling device When in the TIG and Stick...

Страница 11: ...ond time 4 The parameter in the Voltage Display will begin to flash indicating that this has been selected for change 5 Use the Encoder to now adjust this parameter 6 After the desired value is select...

Страница 12: ...3 14 way Socket The 14 way socket is used for the connection of torch triggers interconnection cables and ancillary equipment Pin Function 1 TIG Trigger 2 TIG Trigger 3 Pot GND 4 Pot Wiper 5 Pot 5V 6...

Страница 13: ...t voltage is applied and welding may continue as long as there is welding current and after an internally set time for tacking Thereafter the voltage is once more reduced The time that is allowed for...

Страница 14: ...d fan as well 6 2 Troubleshooting Fault Remedy Power LED does not light Switch the circuit breaker at the rear of the unit to the on position Switch the unit on at the wall plug Make sure the wall plu...

Страница 15: ...Starweld Quatro 450 Operator s Manual 15 7 Electrical Diagrams...

Страница 16: ...Starweld Quatro 450 Operator s Manual 16 8 Parts...

Страница 17: ...00VA Transformer 3 Circuit Breaker 4 HF Transformers 5 WM020 Power Board 6 Input Bridge 7 WM081 Soft Start 8 Output Diodes 9 LEM Module 10 Positive Socket 11 14 Way Socket 12 10A Circuit Breaker 13 WM...

Страница 18: ...excluding misuse and abuse The equipment must be returned to Arc Quip or its agents For service repairs and technical assistance contact your STARWELD dealer or the manufacturer Distributor Starweld...

Отзывы: