3.1 Specifications
Input
Input Voltages
Maximum Input Current
380V
43A
Rated Output
Duty Cycle
Output Amperes
Volts at Rated
Output Amperes
Input Amperes
380V
Stick 100%
450A
38V
43A
TIG 100%
450A
28V
32A
MIG 100%
450A
37.5V
43A
Output
Output Current Range
Open Circuit Voltage
Type of Output
15-450A
55V
DC
Physical Dimensions
Height
Width
Depth
Weight
370mm
350mm
500mm
33kg
Environmental
Operating
Temperature
Range
Storage
Temperature
Range
Relative Humidity Altitude Above
Sea Level
-10
C to +40
C
-50
C to +80
C
Up to 50% at 40
C
Up to 90% at 20
C
Up to 1800m
3.2 Duty Cycle
Duty cycle is the percentage of ten minutes that the unit can weld at selected current
without overheating.
If the unit was used at 450A (Maximum Current) then the unit could weld
continuously, that is no time is needed in order to let the unit cool.
3.3 Selecting Location
The air is blown from the rear of the unit through the heatsink and out the front of the
unit, therefore adequate thought needs to be considered about the location of the
unit.
The unit should be spaced at least 15cm away from a wall at the rear of the
machine, this will allow adequate airflow into the unit.