9

RAID Storage Policies

NOTE: The maximum supported partition size for 32-bit Windows 
systems is 2 TB. Windows cannot detect multiple drives in any RAID 
mode if the total size exceeds 2TB. Hard drives in non-RAID mode 
(JBOD) are supported up to 2TB.

GUI MODE (factory default)

GUI mode allows you to use the SteelVine Manager GUI to set the 
storage policy and other settings as well as monitor the status of 
the enclosure (i.e., storage capacity, and RAID mode of the desired 
hard drive). To select this mode, ensure that the hard disk drives 
are installed, set DIP switch on the back of the device to the GUI 
position and turn on the power. In this mode, no virtual volume(s) will 
be created until the storage policy and volume selections are made 
through the SteelVine Manager GUI. To change from GUI mode to 
some other fixed storage policy thereafter, set the DIP switch to the 
desired position and press the SYS reset button to create the new 
virtual volume(s). 

JBOD MODE

JBOD enables each hard drive to be seen separately, or if only a 
single hard drive is installed. When using a SATA host controller, JBOD 
should only be used if the SATA host controller provides Port Multiplier 
(PM) support. If a host is not PM-aware, only a single drive is visible 
(drive A). No such limitation exists if using a USB host connection. 

Содержание S352U2RER

Страница 1: ...Dual SATAExternal Hard Drive Enclosure 3 5 eSATA USB Dual Removable SATA RAID External Hard Drive Enclosure S352U2RER S352U2RERC Instruction Manual...

Страница 2: ...antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an exp...

Страница 3: ...ion S352U2RERC only 4 Driver Installation 5 Verifying Installation 5 SteelVine Manager Installation 6 Configuration 7 Mode Selection 7 SteelVine Manager Operation 8 RAID Storage Policies 9 GUI MODE fa...

Страница 4: ...r Adapter with power cord 1 x Instruction Manual 1 x PCI Express eSATA controller card S352U2RERC only System Requirements An available USB 2 0 or eSATA port 1 or 2 SATA Hard Drives PCI Express enable...

Страница 5: ...Installation Front View Rear View Power Button Power LED USB Link LED USB Activity LED eSATA Link LED eSATA Activity LED DC Power In 12V SYS Reset USB Connector eSATA Connector RAID Switch Fan Switch...

Страница 6: ...th the supplied screws Slide the trays back into the enclosure until they are fully seated 3 then close the arms Set the dip switches on the rear of the enclosure for the proper 4 mode you want to use...

Страница 7: ...r ie Printers external hard drives etc Unplug the power cable from the rear of the power supply on the back of the computer Remove the cover from the computer case 2 Locate an open PCI Express slot an...

Страница 8: ...on the screen 1 click on the Locate and install drivers software recommended option If prompted to search online select the Don t search online option When prompted to insert the disc insert the Driv...

Страница 9: ...Insert the included CD and AutoPlay will start 1 Select the Install option and proceed through the installation 2 process Once complete you should have the tray icon present from which 3 you can laun...

Страница 10: ...onfiguration Mode Selection Make sure the enclosure is powered on and not connected to a 1 computer system Set the DIP switches to the appropriate mode 2 Press the SYS Reset button 3 SYS Reset DIP Swi...

Страница 11: ...version from the StarTech com website www startech com Launch the SteelVine Manager utility or click on the icon in the 2 system tray Windows only The main window will show you current status of the d...

Страница 12: ...DIP switch on the back of the device to the GUI position and turn on the power In this mode no virtual volume s will be created until the storage policy and volume selections are made through the Stee...

Страница 13: ...hat is equal to the sum of the two drives There is no data redundancy so if one of the disks fail the data on that disk will be lost Once the hard drives A and B are installed in the enclosure set the...

Страница 14: ...s the data is split and written to both disks at the same time but there is no data redundancy If either of the disks fail then all of the data will be lost If two equal capacity hard drives are used...

Страница 15: ...drive is inaccessible When the offline drive comes back online the enclosure will begin the rebuild process immediately to restore data redundancy Although the volume remains available during the reb...

Страница 16: ...to the replacement drive When using a SATA host connection you must have a PM Port Multiplier aware host controller when using SAFE33 If your SATA host adaptor is not PM aware then ONLY the SAFE volum...

Страница 17: ...t to the replacement drive When using a SATA host connection you must have a PM Port Multiplier aware host adapter when using SAFE50 If your SATA host adaptor is not PM aware then ONLY the SAFE volume...

Страница 18: ...B LEDs Power USB Link USB Act eSATA Link eSATA Act HDD A Act HDD A Link HDD B Act HDD B Link Cooling Fan 1 x 50mm Ball Bearing Maximum Data Transfer Rate eSATA 3 Gbps USB 480 Mbps Supported RAID Modes...

Страница 19: ...alent products at our discretion The warranty covers parts and labor costs only StarTech com does not war rant its products from defects or damages arising from misuse abuse alteration or normal wear...

Страница 20: ...name just a few We offer an unmatched selection of computer parts cables A V products KVM and Serv er Management solutions serving a worldwide market through our locations in the United States Canada...

Отзывы: