Manual Revision: 01/07/2019
User Manual
For the latest information and specifications visit
www.startech.com/PEXSAT34RH
4 Port PCIe 2.0 SATA III 6Gbps RAID Controller Card with HyperDuo
Actual product may vary from photos
SKU#:
PEXSAT34RH
Страница 1: ...1 07 2019 User Manual For the latest information and specifications visit www startech com PEXSAT34RH 4 Port PCIe 2 0 SATA III 6Gbps RAID Controller Card with HyperDuo Actual product may vary from photos SKU PEXSAT34RH ...
Страница 2: ... of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Use of Trademarks Registered Trademarks and other Protected Names and Symbols This manual may make r...
Страница 3: ...certifié et dans le respect des normes locales et du code de construction local Les câbles y compris les câbles d alimentation et de chargement doivent être placés et acheminés de façon à éviter tout risque électrique de chute ou de sécurité 安全対策 電源が入っている状態の製品または電線の終端処理を行わないでくださ い 製品の設置やマウントは 使用地域の安全ガイドラインおよび建築基準に 従い 有資格の専門業者が行うようにしてください ケーブル 電源ケーブルと充電ケーブルを含む は 適切な配置と引き回し を行い 電気障害やつまづきの危険性など 安全上のリ...
Страница 4: ... får inte göras när produkten och eller elledningarna är strömförda Installation och eller montering får endast göras av behöriga yrkespersoner och enligt gällande lokala förordningar för säkerhet och byggnormer Kablar inklusive elkablar och laddningskablar ska dras och placeras på så sätt att risk för snubblingsolyckor och andra olyckor kan undvikas ...
Страница 5: ...tements 2 Product Diagram 5 Product Information 6 Packaging Contents 6 System Requirements 6 Installation 6 Hardware Installation 6 Driver Installation 8 Management Utility Installation Windows Only 9 Operation 10 RAID Configuration 10 HyperDuo Configuration 12 Software Operation 15 Create a RAID Array 15 Create a HyperDuo Array 20 Managing Your Array 21 ...
Страница 6: ...5 To view manuals videos drivers downloads technical drawings and more visit www startech com support Product Diagram 4 x SATA III Ports x 2 ...
Страница 7: ...Vista 32 64 bit 7 32 64 bit Server 2008 R2 or 8 32 64 bit Mac OS 10 6 10 7 or 10 8 Linux Installation Hardware Installation Warning PCI Express cards like all computer equipment can be severely damaged by static electricity Be sure that you are properly grounded before opening your computer case or touching your PCI Express card StarTech com recom mends that you wear an anti static strap when inst...
Страница 8: ...press x2 slot and remove the metal cover plate on the rear of the computer case Refer to documentation for your computer system for details Note This card will work in PCI Express slots of additional lanes i e x4 x8 or x16 slots 4 Gently insert the card into the open PCI Express slot and fasten the bracket to the rear of the case Note If installing the card into a small form factor low profile sys...
Страница 9: ...on Windows XP Note The latest driver is available from www startech com 1 Once the computer has started and the operating system is fully loaded insert the provided Driver CD into the computer s CD DVD drive 2 AutoPlay should give you the option to browse the files on the CD or automatically open the CD Autoplay screen ...
Страница 10: ...ile drvSetup exe Follow the onscreen instructions to complete the driver installation Windows Vista 7 8 The driver is natively supported by newer Operating Systems The driver should automatically install through Windows Update Management Utility Installation Windows Only RAID and or HyperDuo configuration can be accomplished either through the integrated card BIOS utility or through the Marvell St...
Страница 11: ...installation click the Next button on each window and accept the License Agreement when displayed 4 Once installation is complete click the Finish button The Marvell Storage Utility has now been installed Operation RAID Configuration Card BIOS Method Warning Creating a RAID virtual disk destroys all data on the physical disks included in the virtual disk set Make sure to back up all data before co...
Страница 12: ...D set Press Space to select de select a disk Note When a disk is selected an asterisk appears to the left of the disk label 5 After selecting the required disks press Enter to continue 6 The Create Virtual Disk configuration options appear in the Information pane right side here you are able to select the RAID level and other configuration options Select 2 HDDs for RAID 0 or RAID 1 Select 3 HDDs f...
Страница 13: ... left HyperDuo Configuration HyperDuo offers the following two modes that you can configure using either of the procedures outlined in the following sections Safe mode creates a virtual disk that is optimized for best fault tolerance the frequently accessed files copied to the SSD for performance are also stored on the HDD It is safe to use with hard drives that contain existing data Virtual disks...
Страница 14: ...ter read and write performance than those created in safe mode However they cannot be rebuilt Warning Capacity mode is a data destructive process Please back up all data before using capacity mode Card BIOS Method 1 When prompted on startup press Ctrl M to enter the card BIOS utility Press Ctrl M to enter BIOS Setup or Space to continue 2 Using the arrow keys to navigate move to HBA0 Marvell 0 and...
Страница 15: ...d disks press Enter to continue 6 The Create Virtual Disk configuration options appear in the Information pane right side here you are able to select HyperDuo or RAID options Note The default HyperDuo mode is Safe mode 7 Highlight Keep original data and press Enter to select Select Yes or No and press Enter Warning Selecting No will destroy all data on the disks included in the virtual disk set Ma...
Страница 16: ...underbolt hard drive enclosure Note Active Scripting or JavaScript must be enabled in your default web browser Create a RAID Array Warning In order to prepare your drives for RAID operation this enclosure will configure newly installed drives into your desired RAID configuration Please be aware that any data currently on the drives may be lost during this process It is recommended that you back up...
Страница 17: ...rtech com support 3 Select Adapter from the Marvell Storage menu then hover over the operation tab and select Create RAID Operations tab 4 The Create New VD window is now displayed using the Select RAID Level drop down menu choose your desired RAID mode Select Raid Level drop down menu ...
Страница 18: ...VDscreen 6 SelecteachdriveyouwouldlikeincludedinyourRAIDarray 7 ClicktheNextButton a default name will now be assigned to your RAID array Note The Next button will not be selectable until the correct number of physical hard drives have been selected to build your desired array Create New VD screen 8 To rename the array click the Name field and type your desired name ...
Страница 19: ...re visit www startech com support 9 Select the Initialization method for your choice from the drop down menu Select Initialization method 10 Select your desired stripe size using the Stripe size drop down menu 11 Click the Submit button to rename the array Submit button ...
Страница 20: ...er of advanced options can also be changed such as Name Initialize setting Cache Modes RAID Set Size Stripe Size and Gigabyte Rounding It is recommended that they are left as their defaults 12 Your RAID array has now been created The Property tab will now be displayed for your newly created RAID array Property tab ...
Страница 21: ...y on the drives may be lost during this process It is recommended that you back up all data prior to setting your HyperDuo configuration 1 Select Adapter from the Marvell Storage menu then hover over the operation tab and select Create HyperDuo Operation tab 2 The Create HyperDuo screen is now displayed Using the Mode drop down menu select Safe Creates an array for optimal fault tolerance Capacity...
Страница 22: ...reate the HyperDuo array Submit button 4 The Property tab will now be displayed for your newly created HyperDuo array Note It can take up to 30 minutes for the HyperDuo array to be created Managing Your Array View Properties of your RAID HyperDuo Array 1 Select the desired array from list of Virtual Disks in the Marvell Storage Menu ...
Страница 23: ... www startech com support 2 The Property tab will appear listing the Properties for your array Property tab Rename Your Array 1 Select the Name field on the Property tab and type your desired Name in the field 2 Click the Modify button to rename the selected array Modify button ...
Страница 24: ... the top of the Property page and select Delete Delete function 2 A warning will be displayed alerting you that all data on the virtual disk will be erased Select OK to acknowledge the warning 3 An additional pop up message will appear warning you that drive data will be lost click Ok to continue 4 A message will now be displayed asking Do you want to delete the partition information if this has o...
Страница 25: ...on Warning When erasing previously configured RAID Data this enclosure will erase all drive data Please be aware that any data currently on the drives will be lost during this process It is recommended that you back up all data prior to erasing previously configured RAID data RAID controllers store data on any drive within a RAID array If your drives have been previously configured in a different ...
Страница 26: ...technical drawings and more visit www startech com support the Marvell Storage Menu Hover over the Operation tab and select Erase Foreign Configuration Erase Foreign Configuration function 2 Your previously installed RAID data will now be deleted ...
Страница 27: ...any damages whether direct or indirect special punitive incidental consequential or otherwise loss of profits loss of business or any pecuniary loss arising out of or related to the use of the product exceed the actual price paid for the product Some states do not allow the exclusion or limitation of incidental or consequential damages If such laws apply the limitations or exclusions contained in ...
Страница 28: ... tools StarTech com is an ISO 9001 Registered manufacturer of connectivity and technology parts StarTech com was founded in 1985 and has operations in the United States Canada the United Kingdom and Taiwan servicing a worldwide market Reviews Share your experiences using StarTech com products including product applications and setup what you love about the products and areas for improvement StarTe...