28 PKG08761-UMSR160
ENGLISH
INSTRUMENT PERFORMANCE
GAGE
Resolution
0.4μin (0.01μm)
MEASUREMENT
Range (Ra)
Up to 1600μin (40μm)
Range (Rz, Rv, Rp, Rt) Up to 7800μin (199μm)
Repeatability
2% of value + noise
Accuracy
5% of r 4μin (0.1μm)
Noise
4μin (0.1μm)
CALIBRATION
Process
Automatic software calibration
Standard
Able to calculate to ISO 4287 Roughness Standards
PARAMETERS
Standards
ISO 4287
ISO 4287 (Roughness) Ra, Rz, Rp, Rv, Rt, Rz1max, Rsk, Rq, Rku
ISO (Primary)
Pa, Pz, Pp, Pv, Pt
TECHNICAL
DATA OUTPUT
On-Screen
Up to 5 results per page, selectable on-
screen graph
BATTERY
Charger
Mini USB 5V 1A 110-240VAC 50/60 Hz
Charging Time
4 hours
POWER
Battery Life
>10,000 measurements per charge
Standby Time
5,000 hours
Instant On
Max 5 sec from standby to ready to measure
Auto-Sleep Function
5 minutes
INSTRUMENT CAPABILITY
PICK-UP ASSEMBLY
Pick-Up Type
Piezoelectric
Stylus Type
Diamond, Radius 200μin (5μm)
GAGE
Gage Force
200mg
Measurement Type
Skidded
FILTER
Filter Type
Gaussian
Filter Cut-Off
0.8mm
TRAVERSE
Traverse Length
0.2in (5mm)
Traverse Speed
0.08in/sec (2mm/sec)
DISPLAY
Units
μin/μm
ENVIRONMENTAL/PHYSICAL
PHYSICAL SPECIFICATIONS
Weight Including Pick-Up
14oz (0.4kg)
Power Source
Li-Poly rechargeable battery
OPERATING CONDITIONS
Temperature
41 - 104°F (5 -40°C)
Humidity
0 - 80% non-condensing
STORAGE
Temperature
32 - 122°F (0 - 50°C)
Humidity
0 - 80% non-condensing
www.
GlobalTestSupply
.com
Find Quality Products Online at: