18
VDE- and DIN provisions. Only use connecting cables
with the H 07 RN designation.
Keeping a copy of the type designation on the connect-
ing cable is a specification
Dmaged electric connecting cables
Insulation damages frequently occur on electric connect-
ing cables. The reasons are:
• Pressure points, if connecting cables are routed
through window or door gaps.
• Kinks due to improper mounting or routing of con-
necting cables.
• Intersections due to overruns of connecting cables.
• Insulation damage due to pulling out from wall sock-
ets.
• Cracks due to ageing of insulation.
Such damaged electric connecting cables should not be
used and can be fatal because of the insulation damage
AC motor 230 V/ 50 Hz
Mains voltage 230 Volt / 50 Hz.
Mains connection and extension cable must have
3-wires = P + N + SL. - (1/N/PE).
Extension cables must have a minimum cross-section of
1.5 mm².
The mains connection is secured with a max. 16A fuse.
Maintenance
Caution! Pull out power plug.
• Clean the machine after each work cycle.
• Replace worn out cutting discs.
• Replace damaged protection device
• Dust and pollution must be removed regularly from the
machine. The best way to clean the machine is with a
piece of cloth or brush.
• All moveable parts must be re-lubricated at periodic
intervals.
• Do not use any corrosive substances to clean the
plastic. A damp cloth is sufficient in most cases.
• The tub (4) and coolant pump (13) must be cleaned
regularly to remove dirt, as otherwise the pump or the
pipe or the cooling of the diamond cutting disc (10) is
not guaranteed.
Service information
Please note that the following parts of this product are
subject to normal or natural wear and that the following
parts are therefore also required for use as consuma-
bles.
Wear parts*: Saw blade, carbon brush, table & cutting
head guides
* Not necessarily included in the scope of delivery!
Spare-part ordering
Please quote the following in your order for spare parts:
• Type of device
• Article No. of device
• Ident. No. of device
• Spare Part No. of the required spare part
Start-up of the leakage current circuit-breaker:
• The function should be checked before each start-up
and at regular Intervals (min. once every week).
• If the leakage current circuit-breaker does
not switch off properly during this test, there
is no personal protection! The device must
therefore be switched off immediately!
• In case of damages caused by the non-observation of
this operating instructions manual, all warranty claims
will become null and void. We do not accept any liabil-
ity for consequential damages.
• Check the product for damage before each use! If you
detect a damage, do not connect the product to the
mains power supply!
• After actuating the orange Reset button, the device
is ready for operation. Before operation, please test
the triggering with the help of the Test button (as de-
scribed in “Operation”).
• Insert the leakage current circuit-breaker into the
socket.
• Press the orange Reset button.
• A red symbol is displayed in the window indicating op-
erational readiness.
• Press the red Test button. This action simulates a
leakage current.
• If the machine is working properly, the circuit-breaker
will disconnect the load from the mains. This is dis-
played in the window through the disappearance of
the red symbol.
• Protection of man and animal is effective only if the
machine works properly.
• The Reset button must be pressed a second time for
operation.
• The load can now be inserted.
Technical data:
Triggering leakage current: < 30 mA
Power supply: 230V~/50Hz
Load capacity: 16A (3680W)
Number of pins: 2-pin wired
Preliminary fuse: 16 A
Protection type: IP54
Dimensions: 126x50x88mm
USE ACCORDING TO MANUFACTURER‘S INSTRUC-
TIONS!
The portable leakage current circuit-breaker is designed
for wet grinding machines and similar electrical loads in
the household.
It is simply connected between the mains power supply
and the load, and therefore offers optimum protection
against physical contact with live components and sud-
den restart of the machine after restoration of power.
• Always operate the machine with the provided leakage
current circuit-breaker installed.