PARTS & FEATURES

Drain Valve:

Used to drain condensation from the air tank. Located at bottom of tank.

Motor Thermal Overload:

The motor has an automatic thermal overload protector. If the motor overheats, this protector will shut off

the motor. The motor must be allowed 30 minutes to cool before restarting.

Quick Connect:

Offers a quick release feature for attaching and removing the air hose.

Oil-Free Pump:

Oil free direct driven pump that compresses air, which is distributed to the tank.

Tank Safety Valve:

Used to allow excess tank pressure to escape into the atmosphere. This valve should only open when the tank

pressure is above the maximum rated pressure.

Outlet Pressure Gauge:

Indicates the outgoing air pressure to the tool and is controlled by the regulator.

Tank Pressure Gauge:

Indicates the reserve air pressure in the tank.

Regulator:

The regulator controls the air pressure coming from the air tank. To increase the pressure, turn the knob clockwise and to

decrease the pressure turn the knob counterclockwise.

INSTALLATION & ASSEMBLY

Lubrication and Oil

This compressor requires no lubrication or oiling. No break in procedure is required by the user.

This product is factory tested to ensure proper operation and performance.

Location of the Air Compressor

The air compressor should always be located in a clean, dry, and well-ventilated

environment. The unit should have at minimum, 30cm of space on each side. The air filter intake should be free of

any debris or obstructions. Check the air filter on a daily basis to be sure it is clean and in working order.

Extension Cords

Use only a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will

accept the plug on the product. Make sure your extension cord is in good condition. When using an extension cord, be

sure to use one heavy enough to carry the current your product will draw. Cords must not exceed 25 feet and No. 12

AWG size must be used. An undersized cord will cause a drop in line voltage resulting in loss of power and

overheating.

Grounding Instructions

This product should be grounded. In the event of an

electrical short circuit, grounding reduces the risk of electric shock by

providing an escape wire for the electric current. This product is equipped with

a cord having a grounding wire with an appropriate grounding plug. The plug

must be plugged into an outlet that is properly installed and grounded in

accordance with all local codes and ordinances. Check with a qualified

electrician or service personnel if these instructions are not completely

understood or if in doubt as to whether the tool is properly grounded.

Содержание 65168

Страница 1: ... KEEP THIS MANUAL FOR SAFETY WARNINGS PRECAUTIONS ASSEMBLY FOR QUESTIONS PLEASE CALL CUSTOMER SERVICE 909 628 4900 SERIAL NUMBER ON THE BACK OF THE MANUAL OR THE MONTH AND VEAR OF PURCHASE IF OPERATION INSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S PRODUCT HAS NO SERIAL NUMBER ...

Страница 2: ... Turn off the air compressor and drain the air tank before performing any type of maintenance or disassembly of the hoses or fittings Never point any nozzle or sprayer toward any part of the body or at other people or animals Risk to Breathing Avoid using the air compressor in confined areas Always have adequate space 30 cm on all sides of the air compressor Also keep children pets and others out ...

Страница 3: ...on and performance Location of the Air Compressor The air compressor should always be located in a clean dry and well ventilated environment The unit should have at minimum 30cm of space on each side The air filter intake should be free of any debris or obstructions Check the air filter on a daily basis to be sure it is clean and in working order Extension Cords Use only a 3 wire extension cord th...

Страница 4: ...to zero on the regulator 4 Remove any air tools or accessories 5 Open the drain valve allowing air to bleed from the tank After all of the air has bled from the tank close the drain valve to prevent debris buildup in the valve Water that remains in the tank during storage will corrode and weaken the air tank which could cause the tank to rupture To avoid serious injury be sure to drain the tank af...

Страница 5: ... leak remains contact a service technician Air leak from safety valve Operate the safety valve manually by pulling on the ring If the valve continues to leak when in the closed position it should be replaced Pressure reading on the regulated pressure gauge drops when an accessory is used If there is an excessive amount of pressure drop when the accessory is used replace the regulator NOTE Adjust t...

Страница 6: ......

Страница 7: ...01 1 48 SCREW M6X20 2 14 BEARING 6201 1 49 5 15 BEARING 6203 1 50 3 16 5 3 ij 1 51 SPRING WASHER M6 3 17 ECCENTRIC 1 52 3 18 BELT 1 53 SCREW M5X12 8 19 SCREW M6X16 1 54 RUBBER FOOT 4 20 COVER OF CONROD 1 55 DRAIN VALVE 1 21 PISTON RING 1 56 HANDLE 1 22 CONROD 1 57 SHROUD 1 23 SCREW M4X20 1 58 TAPPING SCREW ST4X12 2 24 SPRING WASHER M4 1 59 PRESS FIXTURE 1 25 NUT M4 1 60 POWER SWITCH 1 26 ROUND FAN ...

Страница 8: ...erial Number Here __________________ Note If product has no serial number record month and year of purchase instead Note Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts The material in this manual is for informational purposes only The product s it describesare subject to change without prior notice due to the manufacturer s co...

Отзывы: