StarBand Troubleshooting Quick Guide

StarBand Troubleshooting Quick Guide

TM

Task: CVACS - Cross-Pol Testing

Symptom: Unable to access CVACS and commission the site.

Diagnosis #1: Invalid certification Number

Resolution #1: You may have entered the certification number incorrectly, or you are
not StarBand certified, or you may be entering a certification number that is already in
use by a different installer logged into CVACS.

Diagnosis #2: Experiencing problems accessing CVACS with a mobile or landline phone.

Resolution #2:  The phone you are using may be experiencing tone problems, switch to
another phone and attempt to commission again. If using the proper numbers and using
a landline phone, it is likely that more than one installer is attempting to access CVACS
with a shared certification number.  Wait several minutes and attempt to commission the
site.

If your attempts to auto commission the site are unsuccessful contact StarBand technical
support at 1-888-424-4121, the site may require a manual commission.

Note: If you feel that your certification number is being shared, contact StarBand at 703-
245-6394.

Diagnosis #3: The cell phone or mobile phone may be having problems with the touch-
tone sounds.

Diagnosis #4: Shared certification number.

Task: CVACS - Cross-Pol Testing

Symptom: During CrossPol Testing the CrossPol value drops to zero. However, a
final alignment check of the CrossPol registers a high value.

Diagnosis #1: This situation occurs when the carrier wave (CW) drops during repeated
reading part of the CrossPol test. CVACS will not report the loss of CW, but will continue
to report the CrossPol reading as zero. During the final alignment check CVACS sends up
a new CW and takes an actual CrossPol reading, which may then be out of range.

Resolution #1: Periodically check the CoPol readings during alignment.  If the CoPol
drops to zero as well, the CW has dropped. You will need to return to the main menu and
restart the test.

If you reach the final Alignment Check and the reading for Cross-Pol differs from what
you received in the CrossPol Test, go through the CVACS process again.

If CVACS is consistently reporting different CrossPol values during the CrossPol Test and
Alignment Check, contact StarBand technical support at 1-888-424-4121, the site may
require a manual commission.

Содержание 360

Страница 1: ...StarBand Install Troubleshooting Guide ...

Страница 2: ...StarBand Model 360 are trademarks and service marks of StarBand Communications Inc StarBand Install Troubleshooting Guide Overview of Necessary Troubleshooting Steps to Ensure Installation Success DRAFT THIS DOCUMENT IS A WORK IN PROGRESS AND SHOULD ONLY BE USED FOR PILOT PURPOSES PLEASE SEND COMMENTS AND FEEDBACK TO Darrell Spears STARBAND COM StarBand Communications Inc 1760 Old Meadow Road McLe...

Страница 3: ...ned satellite with the correct transmit polarity and receive IFL cable connected to obtain receive lock Subcluster This identifies the specific processor to which the customer is assigned at the hub The site will not connect with the hub if this field is incorrect Satellite Assigned Currently StarBand uses two satellites Telstar 7 at 129WL and AMC 4 formerly known as GE4 at 101W Each customer is a...

Страница 4: ...llation issues using the Troubleshooting Guide StarBand CVACS and Installation Support 1 888 424 4855 StarBand Damaged or Missing Parts 1 888 424 4121 Recommended Troubleshooting Tools Important Please ensure that you review the troubleshooting guide and follow the appropriate steps to resolve the related issue This process should be completed before contacting StarBand technical support ODU Trans...

Страница 5: ...ting FSB SB 0016 1 00 IFL Troubleshooting FSB SB 0020 1 01 StarBand In Line Amplifier Usage FSB SB 0015 1 01 Things you should consider before troubleshooting The weather is clear both at the customer s site and at the hub Line of sight to the satellite from the StarBand antenna is unobstructed No external interference from radar detectors or cell towers is present ...

Страница 6: ... then the Pwr LED is defective Diagnosis 3 Defective AC Power Cable Resolution 3 Unplug the modem and allow it to stand for one full minute Reattach the power cable and power on the modem If this fails to power on the modem attach a standard PC power cable to the modem and to an outlet If this produces modem activity then the original power cable is defective Diagnosis 4 Defective Modem Resolution...

Страница 7: ... IFL cable connecting the LNB to the modem receive cable or DC voltage Resolution 4 Verify the voltage supplied by the modem and received at the LNB is between 16 18V Check IFL cable and connectors for visual signs of damage or kinks and replace if necessary Verify the receive cable is within the specified maximum length 140 ft for RG6 cable To confirm the IFL has failed attach the modem directly ...

Страница 8: ... modem are secure by disconnecting visually inspecting the cable and then firmly reattaching Diagnosis 5 LED is in fault Resolution 5 Right click on the Mission Control icon and select Network Status then click on the Advanced tab If the Connection Status is green then the modem LED has failed Diagnosis 6 Defective Modem Resolution 6 Power cycle the modem and observe the Tx LED to verify it flashe...

Страница 9: ...he LED is defective If troubleshooting is unsuccessful contact StarBand Tech Support at 1 888 424 4121 Diagnosis 1 Bad transmitter due to physical damage Resolution 1 Contact StarBand to request replacement ODU Diagnosis 2 Shortage in the transmitter Resolution 2 To determine if there is a short in the ODU remove the transmit IFL cable from the ODU and set the multimeter to measure resistance in o...

Страница 10: ...e StarBand technical support if a satellite change is needed Diagnosis 3 Receive IFL cable may be defective or length may be too long Resolution 3 Measure resistance in cable using method in FSB SB 0020 1 00 with cable disconnected at both ends and Multimeter on OHMs scale meter should read Open or Infinity With one end of cable shorted the other end should read a nominal resistance value Make sur...

Страница 11: ...ification number is being shared contact StarBand at 703 245 6394 Diagnosis 3 The cell phone or mobile phone may be having problems with the touch tone sounds Diagnosis 4 Shared certification number Task CVACS Cross Pol Testing Symptom During CrossPol Testing the CrossPol value drops to zero However a final alignment check of the CrossPol registers a high value Diagnosis 1 This situation occurs wh...

Страница 12: ...StarBand Communications Inc 1760 Old Meadow Road McLean VA 22101 TM ...

Отзывы: