2M-Z19213 Rev G - Owner's Manual for RTW Rolling T
ortilla Warmer
WIRING DIAGRAM
POWER MUST BE REMOVED FROM THE UNIT BEFORE ATTEMPTING REPAIR OR SERVICE.
MAKE CERTAIN TO CHECK ALL CONNECTIONS THOROUGHLY BEFORE RESTORING POWER
TO THE UNIT. THE BELOW INFORMATION IS FROM WIRING DIAGRAM 2M-Z22547.
Please review the following information before proceeding with any electrical diagnosis or repair.
DRUM ELEMENT:
TEMP CONTROL
CF
TSS
7
i.
Check for proper voltage jumper connection on power board.
ii.
Fan cord, communication cable, IR sensor cable, and tachometer are not numbered.
iii.
Hold back-up nut when tightening element terminals to prevent twisting the cold pin.
iv.
Make certain that infrared sensor is supported when inserting connector.