2M-Z21001 Rev A Owner's Manual fo
r IR
CS4 Impingement/Radiant Split-Belt Conveyor T
oaste
r
7
ADVANCED PROGRAMMING
CREATING A NEW UPDATE FILE
i.
If a .csv file with the correct format for uploading new preset names and settings into the toaster
has not already been loaded onto a USB flash drive, a file with the correct format can be generated
by plugging a USB flash drive into the toaster while it is on.
A flash drive formatted in FAT32
is strongly suggested.
ii.
A screen will appear prompting an upload or download option for the toaster. By pressing the
left-side
▼
, a csv file will be generated with the toaster’s current product settings and names
called “TOASTDN”.
iii.
Remove the flash drive and insert it into a computer with Microsoft Excel or another application
capable of creating .csv files. Open the file and change the product names and settings to the
desired values. Save the file as a .csv file.
FILE REQUIREMENTS
•
PRODUCT NAMES
will only appear in upper case when uploaded and must be 9 characters or less.
•
CYCLE TIME
must be a whole number between 6 and 60.
•
MELT TIME
must be a whole number between 1 and 60.
•
TOP HEATER
must be a whole number between 1 and 10.
•
BOTTOM HEATER
must be a whole number between 1 and 10.
•
FILE NAME
will only appear in upper case when uploaded, must be 8 characters or less.
POSSIBLE WARNING SCREENS
CHECK FAN
Indicates that the unit is approaching its allowable temperature limit. This is meant
to be an early warning to allow the user to clear any blockages to the fan before the
high limit switch trips. If clearing the blockage does not eliminate the warning after
allowing a few minutes for the machine to cool, turn the unit off and contact the
factory or an authorized service agency for required maintenance.
HIGH TEMP SERVICE REQUIRED
Indicates that the high limit switch has been tripped and the unit has overheated.
First turn the unit off and allow it to cool. Check the lower cooling fan and clear the
fan guard of any debris or blockages. Turn the unit back on and ensure warning
does not appear again. If the error is still present, turn the unit off and contact the
factory or an authorized service agency for required maintenance.
HEATER
XX
FAULT
Indicates that a heater circuit has experienced a failure and is no longer functioning.
The screen will display which heater[s] have been detected with open circuits.
XX
will display the position as a two digit abbreviation [TL for top left, TR for top right,
BL for bottom left, and BR for bottom right]. If resetting the power and allowing the
unit to cool does not eliminate the warning, turn the unit off and contact the factory
or an authorized service agency for required maintenance.
HEATER TL FAULT
SERVICE REQUIRED
HIGH TEMP
CHECK FAN