Star Trac 2-Tier Dumbbell Скачать руководство пользователя страница 8

ASSEMBLY

1.

Install the Lower Rack

Install one frame pad (5) onto each foot of the right and left side frames (1, 2). Be sure the foot pads are properly seated
on the frames, and the retaining lips on the end of each pad engage the foot to secure.

2.

Install the Lower Rack

Align the two drilled holes in one rack (3) with the lower mating holes in the left side frame (1). Secure the rack to the
frame using two screws (6), washers (10) and lock nuts (8). Tighten the nuts securely.

Position the right side frame (2) so the two drilled holes in the rack (3) are aligned with the lower mating holes in the
frame.

Secure the frame to the rack using two screws (6), washers (10) and lock nuts (8). Tighten the nuts securely.

3.

Install the Top Rack

Align the two drilled holes in each end of one rack (3) with the top mating holes in the left side frame (1) and right side
frame (2). Secure the rack to both frames using four screws (6), washers (10) and lock nuts (8). Tighten the nuts secure-
ly.

You have now completed assembly of your 

INSTINCT 2-TIER DUMBBELL RACK

.

ANCHORING

IMPORTANT:

The 

INSTINCT 2-TIER DUMBBELL RACK

must be secured to the floor to

stabilize and eliminate rocking or tipping over. This must be performed by a licensed

contractor. Failure to anchor the unit will void the warranty. STAR TRAC shall not be

liable for damage or injury caused by unanchored or improperly anchored units.

The 

INSTINCT 2-TIER DUMBBELL RACK

must be anchored to the floor using through bolts or anchoring studs. Each foot

pad on the unit provides two anchoring holes that will accommodate bolts of up to 12mm (7/16") diameter. Only one hole in each
foot pad is required during anchoring. The holes used for anchoring may be selected based on installation site requirements or
customer preference.

Anchoring bolts/studs must meet the following requirements:

Anchor bolts shall be Grade 8.8 or Grade SAE 5.

Anchoring bolts or studs shall have a minimum size of 6mm (1/4") diameter; 8mm (5/16") diameter bolts/studs are
recommended.

Pull-out force shall be 100kg (2201 lbs) minimum for any single anchor. This will ensure a secure anchoring system and
safe operation of the unit by all users.

ANCHORING

IMPORTANT:

The 

INSTINCT PLATE TREE

must be secured to the floor to stabilize and

eliminate rocking or tipping over. This must be performed by a licensed contractor.

Failure to anchor the unit will void the warranty. STAR TRAC shall not be liable for

damage or injury caused by unanchored or improperly anchored units.

The 

INSTINCT PLATE TREE

must be anchored to the floor using through bolts or anchoring studs. Each foot pad on the unit

provides two anchoring holes that will accommodate bolts of up to 12mm (7/16") diameter. Only one hole in each foot pad is
required during anchoring. The holes used for anchoring may be selected based on installation site requirements or customer
preference.

Anchoring bolts/studs must meet the following requirements:

Anchor bolts shall be Grade 8.8 or Grade SAE 5.

Anchoring bolts or studs shall have a minimum size of 6mm (1/4") diameter; 8mm (5/16") diameter bolts/studs are recom-
mended.

Pull-out force shall be 100kg (2201 lbs) minimum for any single anchor. This will ensure a secure anchoring system and
safe operation of the unit by all users.

STAR TRAC INSTINCT WEIGHT RACKS O

WNER

S

M

ANUAL

13

8

STAR TRAC INSTINCT WEIGHT RACKS O

WNER

S

M

ANUAL

1

2

6

10

5

8

3

3

A

SSEMBLY AND

S

ETUP - S

INGLE

F

RAME

P

LATE

T

REE

PARTS AND MATERIALS

The following parts are included with the 

STAR TRAC INSTINCT SINGLE FRAME PLATE TREE

:

T

OOLS

R

EQUIRED

Most 

STAR TRAC INSTINCT

machines can be assembled using the following tools:

Your 

INSTINCT SINGLE FRAME PLATE TREE

includes a hex key set and combination open-end wrench.

SITING REQUIREMENTS

Your 

INSTINCT SINGLE FRAME PLATE TREE

requires approximately __ square feet of floor space to ensure safe use of the

unit.

UNPACKING

Your 

INSTINCT SINGLE FRAME PLATE TREE

is shipped in one or more shipping cartons. Each carton will generally contain

one subassembly of the entire unit. To unpack:

Remove the shipping straps from the outside of each shipping carton.

Open the top of each carton and fold back all four flaps.

1

Frame, Plate Tree

1

2

Tube, Weight Support

12

3

End Cap

12

4

Pad, Frame

4

5

Grommet, Rubber

12

6

Screw, Button Head Socket Cap, 10X20M

12

7

Washer, 11M

12

Metric Hex Key Wrenches - 2.5mm, 5mm, 6mm, 8mm,
10mm

Metric Open-End Wrenches - 10mm, 15mm, 17mm

Metric Ratchet Socket Wrench Set (including 17mm sock-
et)

Torque Wrench

Channel Lock Pliers

Vice Grip Pliers

Rubber Mallet

Phillips Head Screwdriver - #2

Содержание 2-Tier Dumbbell

Страница 1: ...6 Telephone 800 228 6635 714 669 1660 Fax 714 508 3303 http www startrac com email support startrac com September 2006 Star Trac Instinct WEIGHT RACKS 2 Tier Dumbbell Rack 3 Tier Dumbbell Rack Plate T...

Страница 2: ...neral Guidelines 14 Product Use and Maintenance 14 Preventative Maintenance 14 Maintenance Schedule 14 Maintenance Procedures 15 Labels and Placards 15 Warranty and Disclaimer 16 2 STAR TRAC INSTINCT...

Страница 3: ...STAR TRAC INSTINCT WEIGHT RACKS OWNER S MANUAL 3 18 STAR TRAC INSTINCT WEIGHT RACKS OWNER S MANUAL 2 Tier Dumbbell Rack 3 Tier Dumbbell Rack...

Страница 4: ...to use operate and maintain the Product as set out in your Owners Manual OWNERS MANUAL It is VERY IMPORTANT THAT YOU READ THIS MANUAL before operating the Product Remember to perform the periodic mai...

Страница 5: ...of blending and sanding repaired areas to the surrounding surface is difficult It should be attempted ONLY by persons knowledgeable in this area STAR TRAC INSTINCT WEIGHT RACKS OWNER S MANUAL 5 16 STA...

Страница 6: ...located on a solid level surface 17 Make sure that each machine is set up and operated on a solid level surface DO NOT install equipment on an uneven surface 18 MAINTAIN ALL EQUIPMENT Preventative mai...

Страница 7: ...e Anchoring bolts studs must meet the following requirements Anchor bolts shall be Grade 8 8 or Grade SAE 5 Anchoring bolts or studs shall have a minimum size of 6mm 1 4 diameter 8mm 5 16 diameter bol...

Страница 8: ...he INSTINCT PLATE TREE must be secured to the floor to stabilize and eliminate rocking or tipping over This must be performed by a licensed contractor Failure to anchor the unit will void the warranty...

Страница 9: ...BBELL RACK includes a hex key set and combination open end wrench SITING REQUIREMENTS Your INSTINCT 3 TIER DUMBBELL RACK requires approximately __ square feet of floor space to ensure safe use of the...

Страница 10: ...eter bolts studs are recom mended Pull out force shall be 100kg 2201 lbs minimum for any single anchor This will ensure a secure anchoring system and safe operation of the unit by all users STAR TRAC...

Отзывы: