Star Microwave Cirius SHC , 2016
3.4 CONFIGURATION WINDOW
3.4.1 SWITCH
3.4.1.1 PORT
In the ports window user can read/configure the parameters of Ethernet ports.
Port 1~4 corresponds to front panel electrical Ethernet ports 1~4, and Port 5~7 corresponds front
panel optical Ethernet ports 5~7. Port 8~11 are system internal ports only… please keep these ports
at their default setting.
NOTE:
•
Changing the internal communication ports may cause system errors.
Figure 3-9 Ethernet Ports Window
Table 3-9 Ethernet Port
Port
Speed Rate Parameter
Duplex
Port Disable
Port 1~4
Auto
| 10M |100M | 1000M
Full | Half
Support
Port 5~7
Auto
| 100M | 1G
Full
Support
Table 3-9 Ethernet Port Parameters
Parameter
Range
Default
Remark
Link
-
-
Connect or disconnect
Speed – Current
Speed | Down
-
Speed range refer Table 4-7
Speed - Configured
-
-
Speed range refer Table 4-7
Flow Control
Enable | Disable
Disable
Compliance IEEE 802.3x
Max Frame Size
~9600
9600
The MTU allows pass
NOTE:
•
The bold option is the default parameter of the Ethernet port.