Table 3-3 SRU Information 

Parameter 

Description 

Modulation Mode 

System current modulation mode 

ACM Switch 

System adaptive coding & modulation function status 

Channel Bandwidth 

System current used of channel bandwidth 

ODU Tx Power 

2

nd

 ODU current transmit power 

ODU RSL 

2

nd

 ODU current receive signal level 

ODU ATPC 

2

nd

 ODU ATPC function status 

 

NOTE: 

 

In  order  to  display  the  remote  side  system  information,  you  must  set  the  remote  side  IP 

address so that the local system can 

inquiry and display

The operation of set remote IP address can refer section 

3.4.2.2

 

 

Содержание SM Cirius SHC

Страница 1: ...SM Cirius SHC Digital Microwave Radio Hybrid IP Digital Microwave Indoor Unit User s Manual ...

Страница 2: ...formation contained herein is confidential and the property of Star Microwave Service Corporation and is supplied without liability for errors or omissions No part may be reproduced disclosed or used except as authorised by contract or other written permission The copyright and the foregoing restriction on reproduction and use extends to all media in which the information may be reproduced ...

Страница 3: ...3 1 QUICK CONFIGURATION 20 3 4 CONFIGURATION WINDOW 23 3 4 1 SWITCH 23 3 4 1 1 PORT 23 3 4 1 1 1 ETHERNET PORT SPEED RATE CONFIGURATION 24 3 4 1 1 2 ETHERNET PORT DISABLE 24 3 4 1 1 3 ETHERNET PORT FLOW CONTROL CONFIGURATION 24 3 4 1 1 4 ETHERNET PORT ALLOW MTU CONFIGURATION 24 3 4 1 2 AGGREGATION 25 3 4 1 2 1 AGGREGATION GROUP MENBER CONFIGURATION 26 3 4 1 2 2 AGGREGATION GROUP ALGORITHM CONFIGUR...

Страница 4: ...5 3 4 3 1 MODEM 35 3 4 3 2 ODU 35 3 4 4 MSU 37 3 4 4 1 CHANNEL SWITCH 37 3 4 4 1 1 T1 CONFIGURATION 37 3 4 4 1 2 STM 1 CONFIGURATION 37 3 5 MONITOR 38 3 5 1 SWITCH 38 3 5 1 1 PORT STATUS 38 3 5 1 2 TRAFFIC OVERVIEW 38 3 5 1 3 QOS STATISTICS 39 3 5 1 4 DETAILED STATISTICS 40 3 5 1 5 MAC TABLE 41 3 5 1 6 VLAN MEMBERSHIP 41 3 5 2 MRU 42 3 5 2 1 SYSTEM INFORMATION 42 3 5 2 2 SYSTEM SYSTEM LOG 42 3 5 2...

Страница 5: ... 6 2 1 ACL PORTS 51 3 6 2 2 ACL RATE LIMITERS 52 3 6 2 3 ACCESS MANAGEMENT STATISTICS 53 3 7 DIAGNOSTIC 54 3 7 1 PING 54 3 7 2 VERIPHY 54 3 7 3 DEBUG 55 3 7 3 1 DEBUG MRU 55 3 7 3 2 DEBUG SRU 55 3 7 3 3 DEBUG MSU 56 3 8 MAITENANCE 57 3 8 1 RESTART DEVICE 57 3 8 2 FACTORY DEFAULTS 57 3 8 3 SOFTWARE 57 3 8 4 CONFIGURATION 57 3 9 APPENDIX B RMA RETURN MATERIAL AUTHORIZATION FORM 58 ...

Страница 6: ...crowave Cirius SHC 2016 0 2 HISTORY Change No ENU Details Of Change 1 1 0 0 Initial document released in Sep 2012 2 1 0 1 Revised the description format and update the Web GUI screen capture in September 2013 ...

Страница 7: ...y the symbol label Hazard labeling is supplemented by safety notices in the appropriate equipment manual These notices contain additional information on the nature of the hazard and may also specify precautions Warning These draw the attention of personnel to hazards which may cause death or injury to the operator or others Examples of use are cases of high voltage laser emission toxic substances ...

Страница 8: ...trol MDI Medium Dependent Interface MDI X Medium Dependent Interface Crossover MIB Management Information Base MRU Master Radio Unit MSU Master Service Unit NMS Network management system ODU Outdoor Unit PDH Plesiochronous Digital Hierarchy PLL Phase locked Loop PRBS Pseudo Random Bit Sequence PWD Password QPSK Quadrature Phase Shift Keying RDI Remote Defect Indication RF Radio Frequency RSL Recei...

Страница 9: ... 45 1 AUX and alarm reuse CIT Serial RJ 45 1 RS232 cable OP SFP 1 Support 100 1000 2000Mbps GE 5 6 SFP 2 Support 100 1000Mbps GE 1 4 RJ 45 4 Support 10 100 1000Mbps External Clock MCX 1 2 048MHz clock in out T1 MDR68 0 16 32 TDM interface STM 1 SFP 1 STM 1 transfer interface GND M8 screw 2 Grounding connect position Figure 1 2 0 5U IDU Unit Front Penal Interface GND STM 1 GT1 GE4 GE5 GE7 IF Interf...

Страница 10: ... 438 280 44 W D H mm Weight 4 5Kg 1 1 2 DC POWER IDU required 48V DC power source which maximum current does not exceed 5A and the power positive electrode must connect to ground 1 1 3 CIT IDU support Serial ASCII used Hyper Terminal with RS 232 protocol for the underlying operation Figure 1 3 CIT Port Table 1 4 CIT Port Pin Definition Pin Signal Function Pin Signal Function 1 Reserved 5 GND Groun...

Страница 11: ...ir A BI_DB Bi directional pair B 2 BI_DA Bi directional pair A BI_DB Bi directional pair B 3 BI_DB Bi directional pair B BI_DA Bi directional pair A 4 BI_DC Bi directional pair C BI_DC Bi directional pair C 5 BI_DC Bi directional pair C BI_DC Bi directional pair C 6 BI_DB Bi directional pair B BI_DA Bi directional pair A 7 BI_DD Bi directional pair D BI_DD Bi directional pair D 8 BI_DD Bi directio...

Страница 12: ...n Figure 1 5 TMD RJ 45 BNC Port Table 1 8 T1 RJ 45 Pin Definition Pin Signal Function Pin Signal Function 1 RX Receive data 5 TX Send Data 2 RX Receive data 6 GND Ground 3 GND Ground 7 Reserved 4 TX Send Data 8 Reserved Table 1 9 T1 BNC Pin Definition Pin Signal Function Pin Signal Function Contact RX Receive Data Contact TX Send data Shell GND Ground Shell GND Ground IN 10 OUT ...

Страница 13: ...ments for transmission network management 2 2 IDU SOFTWARE IDU software is responsible for the management monitoring and control of the operational status of the IDU The IDU software is also responsible for communication with the ODU software to manage and control the ODU IDU software management provides a Web GUI access 2 3 ODU SOFTWARE ODU software is responsible for the management and control o...

Страница 14: ...t the PC IP address as the one sharing the same network segment with the IDU IP address The Default IP address of IDU is 192 168 168 1 Step 2 Then Open the browser and input the IDU IP Address in the address field For instance if the IDU IP address is 192 168 168 1 then input the http 192 168 168 1 in the address field Then click Enter key to continue Step 3 Log in with the user name admin and the...

Страница 15: ...tar Microwave Service Corporation IDU model System Mode System current configuration mode System Alarm Indicate system alarm status IP Address Web GUI IP address TDM T1 Trib Num Indicate system current TDM channel quantity Table 3 2 MRU Information Parameter Description Modulation Mode System current modulation mode ACM Switch System adaptive coding modulation function status Channel Bandwidth Sys...

Страница 16: ...el Bandwidth System current used of channel bandwidth ODU Tx Power 2nd ODU current transmit power ODU RSL 2nd ODU current receive signal level ODU ATPC 2nd ODU ATPC function status NOTE In order to display the remote side system information you must set the remote side IP address so that the local system can inquiry and display The operation of set remote IP address can refer section 3 4 2 2 ...

Страница 17: ...rvice Corporation IDU model SN A unique code assigned for identification of a IDU System Mode System current configuration mode System Time System current date and time MAC Address IDU s media access control address IP Address IDU s internet Protocol address use for access Web GUI Monitor Firmware V System current used monitor firmware version MRU FPGA Ver Master Radio Unit FPGA version SRU FPGA V...

Страница 18: ...n whether the modem demodulation normal MER Used to measure the Modulation Error Ratio Table 3 6 ODU Information Parameter Description Firmware Version System current ODU firmware version Tx Frequency ODU transmitter transmitted frequency Rx Frequency ODU receiver received frequency Tx Power ODU current transmit power RSL ODU current receive signal level SSPA Indicate whether the ODU working or mu...

Страница 19: ...ont panel alarm LED indicator will turn on Figure 3 4 Alarm Window Table 3 7 System Alarm Information Parameter Description MRU Modem Alarm MRU modulation or demodulation status abnormality MRU IF Alarm IDU and MRU IF communication error MRU ODU Alarm IDU and 1st ODU communication error SRU Modem Alarm SRU modulation or demodulation status abnormality SRU IF Alarm IDU and SRU IF communication erro...

Страница 20: ...nfiguration Step 1 Parameter Range Default Remark System Time YYYY MM DD hh mm ss System Mode Model and license depends IP Address Default 192 168 168 1 IP Mask Remote IP Address Used to inquiry remote info Next Step Save current page setting and continue setting do not active until Step 4 finish Reset the Step Rest current page setting This operation doesn t affect the previous page setting Figur...

Страница 21: ...ive and turn gray unable to select according to the system modes which were set in Quick Configuration step 1 Figure 3 7 Quick Configuration Step 3 Parameter Range Default Remark MRU SSPA On Off On MRU Tx Power ODU hardware dependent MRU Tx Frequency ODU hardware dependent MRU ATPC Switch Enable Disable Disable MRU ATPC Trigger 60 Range depends on hardware MRU RSL Alarm Th 90 20dBm 90 SRU SSPA On ...

Страница 22: ...Star Microwave Cirius SHC 2016 Figure 3 8 Quick Configuration Last Step Save Configuration Save all parameter settings and apply immediately ...

Страница 23: ...internal communication ports may cause system errors Figure 3 9 Ethernet Ports Window Table 3 9 Ethernet Port Port Speed Rate Parameter Duplex Port Disable Port 1 4 Auto 10M 100M 1000M Full Half Support Port 5 7 Auto 100M 1G Full Support Table 3 9 Ethernet Port Parameters Parameter Range Default Remark Link Connect or disconnect Speed Current Speed Down Speed range refer Table 4 7 Speed Configured...

Страница 24: ... refresh Step 4 Check whether Speed Current display down status End 3 4 1 1 3 ETHERNET PORT FLOW CONTROL CONFIGURATION Step 1 Click Configuration Switch Ports in Functional Navigation Tree Step 2 Click corresponding port Flow Control Configured and click Save Step 3 Wait for the page refresh Flow Control Current Tx Rx will display tick icon End 3 4 1 1 4 ETHERNET PORT ALLOW MTU CONFIGURATION Step ...

Страница 25: ...mand user can use of combinations of different algorithms to build up the aggregation network Figure 3 11 Aggregation Algorithms in OSI Source MAC Address allows Ethernet data with different source MAC address to be arranged to transmit in different links evenly Destination MAC Address allows Ethernet data with different destination MAC address to be arranged to transmit in different links evenly ...

Страница 26: ...nsmit in different links evenly 3 4 1 2 1 AGGREGATION GROUP MENBER CONFIGURATION Step 1 Click Configuration Switch Aggregation Static in Functional Navigation Tree Step 2 Tick appropriate port number in Port Members to the same Group ID Step 3 Click Save and wait for the page refresh End NOTE One port number can only be a member of one group not for multiple groups Normal group is default and is n...

Страница 27: ...End NOTE The algorithms will take effect to the entire aggregation group and do not support independent algorithms for each aggregation group 3 4 1 3 SPANNING TREE In spanning tree window user can enable disable the Spanning Tree Protocol STP for each port Figure 3 12 Spanning Tree Window Parameter Range Default Remark Port 1 11 Enable Disable Disable NOTE STP enable can effectively avoid broadcas...

Страница 28: ...e 1 11 Learn specified static MAC Static Delete Delete current MAC entry Static VLAN ID 1 4096 1 VLAN ID of static MAC table Static MAC adder xx xx xx xx xx xx Static Port Memb 1 11 Port needs to learn this MAC NOTE If the aging time is too long a large number of outdated MAC address entries will be accumulated and lead to the failure of updating the MAC address forwarding list based on the networ...

Страница 29: ... 4 3 DISABLE PORT MAC LEARNING FUNCTION Step 1 Click Configuration Switch MAC Table in Functional Navigation Tree Step 2 Select the appropriate port members to Disable group Step 3 Click Save and wait for the page refresh End 3 4 1 4 4 ADD STATIC MAC TO PORT MAC TABLE Step 1 Click Configuration Switch MAC Table in Functional Navigation Tree Step 2 Select the appropriate port members to Secure grou...

Страница 30: ...t Members 1 11 Port default VLAN ID 1 3 4 1 5 1 ADD NEW VLAN ENTRY Step 1 Click Configuration Switch VLANs VLAN Membership in Navigation Tree Step 2 Click Add new entry key in the appropriate VLAN ID and VLAN Name and select the ports to be the members of this VLAN Step 4 Click Save and wait for the page refresh End 3 4 1 5 2 DELETE VLAN ENTRY Step 1 Click Configuration Switch VLANs VLAN Membershi...

Страница 31: ...eters setting can be skipped 3 4 2 1 1 CHANGE SYSTEM MODE Step 1 Click Configuration MRU System Information in Function Navigation Tree Step 2 Click the drop down menu and select the appropriate value in System Mode Step 3 Click Save and wait for the page refresh End NOTE Some pages will display different item based on system mode 3 4 2 1 2 CHANGE SYSTEM TIME Step 1 Click Configuration MRU System ...

Страница 32: ... 255 0 IP Router 0 0 0 0 Gateway Remote IP Address Used to inquiry remote info VLAN ID 1 4096 1 Web GUI VID 3 4 2 3 MODEM Figure 3 17 MRU Modem Window Parameter Range Default Remark ACM Switch On Off Off License dependent Modulation Mode QPSK 256QAM License dependent Bandwidth ETSI FCC MER Modulation Error Ratio Current Tx Mod QPSK 256QAM Current Rx Mod QPSK 256QAM ...

Страница 33: ...Navigation Tree Step 2 Select On or Off in ACM Switch Step 3 Click Save and wait for the page refresh End NOTE Once the ACM function has been enabled the modulation mode will lock auto mode 3 4 2 4 ODU Figure 3 18 MRU ODU Window Parameter Range Default Remark SSPA On Off On Tx Power Hardware dependent Current Tx Power Shown system Tx power RSL System receive signal level Tx Frequency Hardware depe...

Страница 34: ...the Tx power range Step 3 Click Save and wait for the page refresh End 3 4 2 4 3 FREQUENCY CONFIGURATION Step 1 Click Configuration MRU ODU in Function Navigation Tree Step 2 Key in the appropriate value in Tx Frequency according the Tx frequency range Step 3 Base on the system set ODU is High Prime or Low Non Prime Step 4 Key in the appropriate value in Tx Spacing Step 5 Click Save and wait for t...

Страница 35: ... Modulation Error Ratio Current Tx Mod QPSK 256QAM Current Rx Mod QPSK 256QAM 3 4 3 2 ODU Figure 3 20 SRU ODU Window Parameter Range Default Remark SSPA On Off On Tx Power Hardware depends Current Tx Power Shown system Tx power RSL System receive signal level Tx Frequency Hardware depends Rx Frequency Depends on Tx fre spacing ATPC Enable Enable Disable Disable ATPC function ATPC Trigger Level 60 ...

Страница 36: ...Star Microwave Cirius SHC 2016 RSL Alarm Thresh 90 20dBm 90 NOTE The SRU page displays items and parameters that change based on the system mode as 1 1 HSB SD FD or 2 0 ...

Страница 37: ...tep 1 Click Configuration MSU T1 in Function Navigation Tree Step 2 Select Enable to enable the 16 ways T1 or Disable to disable the T1 Step 3 Click Save and wait for the page refresh End 3 4 4 1 2 STM 1 CONFIGURATION Step 1 Click Configuration MSU T1 in Function Navigation Tree Step 2 Select Enable to enable the STM 1 or Disable to disable the STM 1 Step 3 Click Save and wait for the page refresh...

Страница 38: ... Figure 3 22 Port Status Window 3 5 1 2 TRAFFIC OVERVIEW Figure 3 23 Traffic Overview Window Parameter Description Port Support click in to check the port detail statistics Packets Rx Count received quantity of packet Packets Tx Count transmitted quantity of packet Bytes Rx Count received quantity of Bytes Bytes Tx Count transmitted quantity of Bytes Errors Rx Count received quantity of error pack...

Страница 39: ...on received Clear Clear the page statistics and restart the counting 3 5 1 3 QOS STATISTICS Figure 3 24 QoS Statistics Window Parameter Description Q1 Q7 Rx Count the received packet number on each queue of port Q1 Q7 Tx Count the transmitted packet number on each queue of port ...

Страница 40: ... of different frame sizes Tx Size Counters Count the total transmitted numbers of different frame sizes Rx Queue Counters Count the total received packet numbers of queue Tx Queue Counters Count the total transmitted packet numbers of queue Rx Errors Counters Count the total received error packets Tx Errors Counters Count the total transmitted error packets NOTE Each counter provides more detailed...

Страница 41: ...te type of MAC address include static and dynamic VLAN VLAN ID of MAC address MAC Address The details of MAC address Port Members Indicate which ports had learned this MAC entry 3 5 1 6 VLAN MEMBERSHIP Figure 3 27 VLAN Window Parameter Description VLAN ID Port Members Indicate which ports had this VLAN ID entry ...

Страница 42: ...TEM SYSTEM LOG Figure 3 29 System Log Window Parameter Description ID The ID of system event Level System defined event level as Info Warning Error Time The date event happened Message The details of system event Clear Clear the all the system events NOTE User can use the event level filter to quickly find an event ...

Страница 43: ...al The time period to record the RSL ID The ID of RSL record Time The record date of RSL event RSL dBm The recorded received signal level 3 5 2 4 TEMPERATURE Figure 3 31 System Temperature Window Parameter Description Chip Temperature The temperature of IDU CPU Device Temperature The temperature of IDU shell internal ...

Страница 44: ...U Modem Status Window Parameter Description Demodulation Status Indicate whether the modem demodulation is working normally Tx Channel Status Indicate the Transmit channel status 3 5 2 6 IF Figure 3 33 MRU IF Window 3 5 2 7 ODU Figure 3 34 MRU ODU Status Window ...

Страница 45: ...Star Microwave Cirius SHC 2016 3 5 2 8 ALARM Figure 3 35 MRU Alarm Window ...

Страница 46: ...Star Microwave Cirius SHC 2016 3 5 3 SRU 3 5 3 1 SYSTEM RSL LOG Figure 3 36 SRU RSL Log Window 3 5 3 2 MODEM Figure 3 37 SRU Modem Status Window 3 5 3 3 IF Figure 3 38 SRU IF Window ...

Страница 47: ...Star Microwave Cirius SHC 2016 3 5 3 4 ODU Figure 3 39 SRU ODU Status Window 3 5 3 5 ALARM Figure 3 40 SRU Alarm Window ...

Страница 48: ...Star Microwave Cirius SHC 2016 3 5 4 MSU 3 5 4 1 T1 Figure 3 41 T1 window ...

Страница 49: ...can be any number or letter and the length should be less than 31 characters 3 6 1 2 AUTHENTICATION METHOD In the authentication method configuration window user can configure the authentication method of the client side Figure 3 43 System Authentication Window Parameter Range Default Remark Telnet Local None Local Allow deny telnet access SSH Local None Local Allow deny SSH access Web Local None ...

Страница 50: ...e Enable Enable disable SSH mode 3 6 1 4 HTTPS Figure 3 45 System HTTPS Window Parameter Range Default Remark Mode Enable Disable Enable Enble disable https mode Automatic Redirect Enable Disable Disable Enable disable auto redirect NOTE HTTPS access mode will be activated when both Mode and Automatic Redirect are enabled ...

Страница 51: ...Disable Disable Enable disable this function TELNET SSH Enable Disable Disable Enable disable this function 3 6 2 NETWORK 3 6 2 1 ACL PORTS In the ACL ports configuration window user can limit port speed and configure port copy Figure 3 47 System ACL Ports Window Parameter Range Default Remark Port 1 11 Action Permit Deny Permit Data transmission function Rate Limiter ID Disable 1 16 Disable 1 16 ...

Страница 52: ... Port 6 Cable Connection Cable Connection Cable Connection Cable Connection Port Copy Port Copy Port Copy Port Copy 3 6 2 2 ACL RATE LIMITERS Figure 3 49 Rate Limiter Window Parameter Range Default Remark Rate Limiter ID 1 16 ID of rate limit entry Rate Data transmission function Unit Kbps Kbps Speed rate unit ...

Страница 53: ... 3 ACCESS MANAGEMENT STATISTICS Figure 3 50 Access Statistics Window Parameter Description HTTP Packet statistics of HTTP mode HTTPS Packet statistics of HTTPS mode Telnet Packet statistics of Telnet mode SSH Packet statistics of SSH mode ...

Страница 54: ...nspect the Ethernet link status between the IDU and a target device Figure 3 51 Ping Window 3 7 2 VERIPHY VeriPHY are used for verify the Ethernet PHY layer status and measure the length of cable which connects to port 1 4 electrical Ethernet port in the IDU front panel Figure 3 52 VeriPHY Window NOTE VeriPHY can measure the cable length which should be less than 7m ...

Страница 55: ...ormal Used for maintenance only Modem Onetone Enable Disable Disable Used for maintenance only Onetone Frequency 340000 340MHz Uncoded BER Modem BER statistics Coded BER Modem BER statistics Cumulative BER Modem BER statistics NOTE If loopback modem loopback and modem onetone will interrupt the microwave link remember to disable after maintenance is completed 3 7 3 2 DEBUG SRU Figure 3 54 SRU Debu...

Страница 56: ...dow Parameter Range Default Remark STM 1 Line Loop Normal Loop Normal Used for maintenance only STM 1 System Loop Normal Loop Normal Used for maintenance only T1 Line Loop Normal Loop Normal Used for maintenance only T1 System Loop Normal Loop Normal Used for maintenance only ...

Страница 57: ...ory Default reset will clear all the parameters which had been configured and will interrupt the microwave link but will not automatically recover 3 8 3 SOFTWARE If necessary in the software page the user can upgrade the system firmware in order to improve the system performance or reliability 3 8 4 CONFIGURATION In the configuration page user can save or load the system configuration file which c...

Страница 58: ...scription 1 2 3 4 5 6 7 8 9 10 Notes 1 For Return Category column please select from A Return of Defective Product B Return of Trial Sample or C Return of New and Unused Product 2 If A or C category of return product is chosen please give short description of the problem or reason for returning Transportation Information Location of Product Transportation Method Shipping Forwarder Note Location of...

Страница 59: ...Star Microwave Cirius SHC 2016 Star Microwave Service Corporation 41458 Christy St Fremont CA 94538 Tel 1 510 498 7900 Fax 1 510 498 7901 ...

Отзывы: