background image

 

 

 

Pay attention to all paragraphs marked with this sign. These paragraphs  
contain important hints that will ensure smooth operation of the lift. 
 
WARNING! Important safety advice! Observing these instructions greatly 
reduces the possibility of hazardous situations.  
 
Pay attention! Do not execute the actions marked with this sign! 

• 

The lift must not be overloaded. The maximum capacity of the lift is indicated on the 
front face of the carriage.  

 

 

Safe working load:  250kg wheelchair & occupant (unless payload 300kg or  

 

 

 

 

more). 

 

 

 

 

• 

The emission sound pressure level for lift users is not expected to exceed 60dB(A). 

• 

This platform lift must only be used for the transport of persons in wheelchairs or sitting 
on the optional fold down seat. Never use the lift in a standing position.  

• 

This lift is designed to carry the majority of Type A and B wheelchairs, but not Type C 
wheelchairs or electric scooters due to their weight and size. 

• 

This lift is not designed for carrying goods or animals of any kind. The exceptional use 
by trained guide dogs is permitted. 

• 

Do not exceed the maximum platform load or maximum wheelchair size. 

• 

Remove key switch from both the lift and the platform after use.  

• 

Children should not be allowed to tamper or play with the lift.  

• 

Keep hands and fingers away from the back of the carriage. 

• 

Passengers must remain in the wheelchair or seat while the lift is operating. 

 

Persons walking up or down the stairs while the lift is being operated must avoid contact 
with the platform. Platform users should take into consideration that the platform needs 
more space in a bend than on a straight railway. Therefore, before moving, look to see if 
anyone is using the stairs or if there are obstacles. 
 
Emergency stop

Emergency stop

Emergency stop

Emergency stop    
An emergency stop is fitted on the carriage. In case of emergency press the red STOP-
switch and the lift will stop immediately. To release the STOP-switch, it will be necessary to 
press it once more or to turn it clockwise. 
 

 

We recommend preventive checks are carried out on the lift. Regular servicing of your 
stairlift will ensure safe operation for a long time. Any abnormal operation of the lift 
should be reported to the service office. In the case of irregularities such as vibrations or 
abnormal noise emissions, do not use the lift; call your Service Office.  

 

S A F E T Y   I N S T R U C T I O N S  

Содержание STAIRISER SR

Страница 1: ...STAIRISER SR USER HANDBOOK IMPORTANT Before using your Stannah Stairiser platform lift please ensure that you read and familiarise yourself with these instructions...

Страница 2: ...annot be held responsible for any damage or injury resulting in negligence or misuse of this Stairiser Introduction 3 Safety Instructions 6 General Layout 7 Operating Instructions 10 Emergency Operati...

Страница 3: ...lar inspection and servicing by a competent person at intervals of at least every six months after the guarantee period has expired A Service Log Card supplied by the Service Branch will be completed...

Страница 4: ...ough Examination What is the difference between Maintenance and Thorough Examination What is the difference between Maintenance and Thorough Examination Maintenance Maintenance Maintenance Maintenance...

Страница 5: ...pproaching 20 years in service Actual life expectancy of a lift depends on a number of factors including The load the lift actually carries on each journey The actual lift travel as this determines th...

Страница 6: ...atform load or maximum wheelchair size Remove key switch from both the lift and the platform after use Children should not be allowed to tamper or play with the lift Keep hands and fingers away from t...

Страница 7: ...age cover 6 Directional control 7 Folding seat option 8 Main control button at the carriage side 9 Green lamp 8 7 2 9 1 3 5 4 4 8 6 3 Drive Drive Drive Drive behind the carriage sidewall 1 Gear box 2...

Страница 8: ...not in the stop position within 5 minutes after use the beeper will sound every second If so please bring the platform to the stop position If the lift is parked in the stop position and the beeper st...

Страница 9: ...n trols The controls are supplied by one 9 volt battery A connection cable to a constant power sup ply is possible The life time of the battery is approximately one year In general the battery is usua...

Страница 10: ...e main power switch By switching off the main power switch the lift cannot be used also disables the wall controls If the main power switch and the key switch are switched on the green lamp on top of...

Страница 11: ...sing the Open button Press the button as long as it takes that the platform is in a horizontal position and the barrier has opened completely Simultaneously the ramps turn down to the correct position...

Страница 12: ...e 1 If there is any danger immediately stop the movement of the lift by re leasing the pressed button Switch off the platform control by turning the key into OFF position Take out the key When the unl...

Страница 13: ...at the side of the platform On some models there may also be a key switch at the side of the platform 1 Key switch 2 Emergency Stop 3 Barriers 4 Carriage cover 5 Drive controls Up Down 6 Green lamp W...

Страница 14: ...il the barrier opens If you don t want to stop at an intermediate stop position briefly release the drive button and activate it again in the same direction The lift will briefly stop and then continu...

Страница 15: ...you have to switch on the wall control by putting in and turning the key Press the UP button and the platform folds up as long as you hold the button Press the UP button until the platform is folded...

Страница 16: ...platform wall wall wall wall 1 Switch off main power switch 2 Insert hand wheel 3 Tighten the hand lever for break release and turn the hand wheel until the next station has been reached 4 At every l...

Страница 17: ...el 3 Tighten the hand lever for break release and turn the hand wheel until the position has been reached where the dis tance between the rail and the steps are minimal 4 Emergency unclamping of the b...

Страница 18: ...low Attention Attention Attention Attention The red marked lever must be pressed for unlocking the barri er up to the stairs Do not press the unmarked lever in this case the downside barrier would be...

Страница 19: ...e 4 The carriage has to stop automatically at every stop position 5 The carriage must stop when the directional control is released The brake has to be activated immediately 6 The emergency stop butto...

Страница 20: ...lowing When a landing control is activated it automatically deactivates all other wall con trols i e the complete lift can only be controlled by one control at a time If a wall control activates the p...

Страница 21: ...21 TROUBLE SHOOTING GUIDE...

Страница 22: ...22 TROUBLE SHOOTING GUIDE...

Страница 23: ...hours Our Guarantee does not cover repairs replacements or adjustment which may be required as a result of ordinary wear and tear wilful or accidental damage misuse neglect or any other cause beyond...

Страница 24: ...from negligence or misuse of this lift equipment We are continually developing and improving the Stairiser range and we therefore reserve the right to alter or amend the specification without prior n...

Отзывы: