background image

Stanley TLM165I

10

EN

Technical Data

* applies for 100 % target reflectivity (white painted 

wall), low background illumination, 25 ºC
** applies for 10 to 500 % target reflectivity, high back-

ground illumination, -10 ºC to 50 ºC
*** Tolerances apply from 0.05 m to 10 m with a confi-

dence level of 95%. The maximum tolerance may 

deteriorate to 0.15 mm/m between 10 m to 30 m and 

to 0.2 mm/m for distances above 30 m
**** applies for 100 % target reflectivity, background 

illumination of approximately 30'000 lux

Distance measurement

Typical Measuring Tolerance*

± 1.5 mm / 0.06 in ***

Maximum Measuring Toler-

ance**

± 3.0 mm / 0.12 in ***

Range at Target Plate

60 m / 197 ft

Typical Range*

50 m / 164 ft

Range at unfavourable condi-

tion ****

40 m / 132 ft

Smallest unit displayed

1 mm / 1/16 in

Ø laser point

at distances

6 / 30 mm

(10 / 50 m)

General

Laser class

2

Laser type

635 nm, < 1 mW

Protection class

IP54 (dust- and splash 

water protected)

Autom. laser switch off

after 90 s

Autom. power switch-off

after 180 s

Battery durability (2 x AAA)

up to 3000 measure-

ments

Dimension (H x D x W)

104 x 58.8 x 29.6 mm

4.25 x 2.31 x 1.17 in

Weight (with batteries)

100 g / 3.53 oz

Temperature range:

- Storage

- Operation

-25 to 70 °C

-13 to 158 °F

-10 to 50 °C

14 to 122 °F

Functions

Distance measuring

yes

Min/Max measuring

yes

Permanent measuring

yes

Addition/Subtraction

yes

Area

yes

Volume

yes

Pythagoras

2-point, 3-point

Memory

5 results

Содержание TLM165I

Страница 1: ...ing Functions 6 Measuring single distance 6 Permament measuring 6 Add Subtract 6 Area 7 Volume 7 Pythagoras 2 point 8 Pythagoras 3 point 8 Memory 5 last results 9 Technical Data 10 Message Codes 11 Ca...

Страница 2: ...tentially hazardous situation or an unintended use which if not avoided will result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use which if not avo...

Страница 3: ...Battery Units Area Volume Min Max Measuring Measuring reference Info Addition Subtraction Pythagoras Memory Main line Insert batteries i To ensure a relia ble use do not use zinc carbon batteries Cha...

Страница 4: ...action If the info icon appears with a number observe the instruc tions in section Message Codes Example Adjusting measuring reference Distance is measured from the front of the device 1 Distance is...

Страница 5: ...Stanley TLM165I Operations 5 EN Distance unit setting 0 000m 0 00 1 16 0 in 1 16 Switch between the following units 2 sec Multifunctional endpiece...

Страница 6: ...measuring time increases Permament measuring 1 2 sec 8 532 m Aim active laser at target 2 The last value mea sured is displayed Stops permanent measuring 3 Add Subtract 7 332 m 1 The next meas urement...

Страница 7: ...sec ond target point 24 352 m2 5 i The result is shown in the main line and the measured value above Volume 1 2x 2 Aim laser at first target point 3 4 Aim laser at sec ond target point 5 6 Aim laser...

Страница 8: ...ressing the meas uring key for 2 sec in the function acti vates automatically Minimum or Maxi mum measure ment Pythagoras 3 point 1 4x 2 Aim laser at up per point 3 4 Aim laser at rec tangular point 5...

Страница 9: ...Stanley TLM165I Measuring Functions 9 EN Memory 5 last results 8 294 m 5 5 last results are displayed 1 5x 8 294 m 5 Navigates trough 5 last results 2...

Страница 10: ...ce 3 0 mm 0 12 in Range at Target Plate 60 m 197 ft Typical Range 50 m 164 ft Range at unfavourable condi tion 40 m 132 ft Smallest unit displayed 1 mm 1 16 in laser point at distances 6 30 mm 10 50 m...

Страница 11: ...www STANLEYLASERS com www STANLEYTOOLS com www STANLEYTOOLS eu The company above is responsible for supplying the product including the User Manual in a completely safe condition The company above is...

Страница 12: ...been subject to abnormal use and before during and after important measurements CAUTION Never attempt to repair the product your self In case of damage contact a local dealer WARNING Changes or modif...

Страница 13: ...he receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dea...

Отзывы: