background image

Stanley TLM165I

6

EN

Measuring Functions

Measuring single distance

1

Aim active laser at target.

2

8.532 

m

3

i

Target surfaces: Measuring 

errors  can occur when meas-

uring to colourless liquids, 

glass, styrofoam or semi-per-

meable surfaces or when 

aiming at high gloss surfac-

es. Against dark surfaces the 

measuring time increases.

Permament measuring

1

2 sec

8.532 

m

Aim active laser at target.

2

The last value mea-

sured is displayed.

Stops permanent measuring.

3

Add / Subtract

7.332 

m

1

The next meas-

urement is added 

to the previous 

one.

2

1x

1x

2x

The next meas-

urement is sub-

tracted from the 

previous one.

5.5I5 

m

I2.847 

m

3

i

The result is shown in the 

main line and the measured 

value above. This process 

can be repeated as required. 

The same process can be 

used for adding or subtracting 

areas or volumes.

Содержание TLM165I

Страница 1: ...ing Functions 6 Measuring single distance 6 Permament measuring 6 Add Subtract 6 Area 7 Volume 7 Pythagoras 2 point 8 Pythagoras 3 point 8 Memory 5 last results 9 Technical Data 10 Message Codes 11 Ca...

Страница 2: ...tentially hazardous situation or an unintended use which if not avoided will result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use which if not avo...

Страница 3: ...Battery Units Area Volume Min Max Measuring Measuring reference Info Addition Subtraction Pythagoras Memory Main line Insert batteries i To ensure a relia ble use do not use zinc carbon batteries Cha...

Страница 4: ...action If the info icon appears with a number observe the instruc tions in section Message Codes Example Adjusting measuring reference Distance is measured from the front of the device 1 Distance is...

Страница 5: ...Stanley TLM165I Operations 5 EN Distance unit setting 0 000m 0 00 1 16 0 in 1 16 Switch between the following units 2 sec Multifunctional endpiece...

Страница 6: ...measuring time increases Permament measuring 1 2 sec 8 532 m Aim active laser at target 2 The last value mea sured is displayed Stops permanent measuring 3 Add Subtract 7 332 m 1 The next meas urement...

Страница 7: ...sec ond target point 24 352 m2 5 i The result is shown in the main line and the measured value above Volume 1 2x 2 Aim laser at first target point 3 4 Aim laser at sec ond target point 5 6 Aim laser...

Страница 8: ...ressing the meas uring key for 2 sec in the function acti vates automatically Minimum or Maxi mum measure ment Pythagoras 3 point 1 4x 2 Aim laser at up per point 3 4 Aim laser at rec tangular point 5...

Страница 9: ...Stanley TLM165I Measuring Functions 9 EN Memory 5 last results 8 294 m 5 5 last results are displayed 1 5x 8 294 m 5 Navigates trough 5 last results 2...

Страница 10: ...ce 3 0 mm 0 12 in Range at Target Plate 60 m 197 ft Typical Range 50 m 164 ft Range at unfavourable condi tion 40 m 132 ft Smallest unit displayed 1 mm 1 16 in laser point at distances 6 30 mm 10 50 m...

Страница 11: ...www STANLEYLASERS com www STANLEYTOOLS com www STANLEYTOOLS eu The company above is responsible for supplying the product including the User Manual in a completely safe condition The company above is...

Страница 12: ...been subject to abnormal use and before during and after important measurements CAUTION Never attempt to repair the product your self In case of damage contact a local dealer WARNING Changes or modif...

Страница 13: ...he receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dea...

Отзывы: