SAFETY VALVE

Pic. 10

NOTE: When checking the safety valve ALWAYS wear  
safety glasses.
To check the operation of the safety valve the air tank will 
need to be full.  Gently pull the ring outwards. This should 
release air under pressure.  Release the ring and this should 
stop the air out flow immediately.
If the safety valve does NOT work in this manner,  
STOP the air compressor immediately and have the  
air compressor checked / serviced by an authorised  
service centre.

PIC. 12

DRAIN TAP

Pic. 12

After use open the drain tap to drain excess air and any 
moisture.  The excess air will also help purge the moisture.  
Leave the drain tap open when air compressor is not in use, 
so any moisture can continue to drain
To open the drain tap pull the lever down to vertical. 
To seal the drain tap push the lever up to horizontal.
NOTE: Remember to seal the drain tap before starting  
the compressor.

Drain Tap Sealed

OR

To close and seal push lever up Right or left

Drain tap opened un-sealed

AIR FITTING

Pic. 11

This air compressor is fitted with a ‘Nitto style’  
(female) socket.
1.  Push in the ‘Nitto style’ male plug (not included).
2.  Fully and completely push the ‘Nitto style’ male plug  
  (not included) into the ‘Nitto style’ female socket until  
  it clicks and the collar locates forward.

To remove

1.  Push collar down and remove male fitting,  
  collar will stay retracted.

NOTE:  For ease of connection and disconnection use 
regulator to reduce outlet pressure to 0PSI.
This compressor has a maximum pressure of 145PSI  
(10 bar).  
Always regulate the outlet air pressure to match your  
air tool.  
Different air tools require different operating pressures.  
Always check with the air tool manufacturer if unsure.

PIC. 11

PIC. 10

Pull to check 

operation 

Outlet pressure gauge

Nitto style outlet 

socket (air outlet)

Tank pressure gauge

Содержание SXCM27550323

Страница 1: ...04078 02 20 MODEL NO SXCM27550323 AIR COMPRESSOR TWIN STACK 2 75HP 50L For service spare parts or product information please contact Smart Marketing Group Pty Ltd AUST 1300 660 457 N Z 0800 474 876...

Страница 2: ...Place of Purchase Receipt Number Always check the air requirement of the tool wishing to be used to ensure that it is within this air compressor s air output SUGGESTED APPLICATIONS You may use most a...

Страница 3: ...h parts and components of similar quality grade and composition where an identical part or component is not available Products presented for repair may be replaced by refurbished products of the same...

Страница 4: ...rts of the product with parts and components of similar quality grade and composition where an identical part or component is not available Products presented for repair may be replaced by refurbished...

Страница 5: ...or wax Always leave sufficient distance at least 5 metres between the air compressor and the work area especially when using tools designed for sanding or spraying liquids If needed use a longer air h...

Страница 6: ...authorised service facility Keep handles clean dry and free from oil and grease Ensure that ventilation slots are kept clean and free from dust at all times Blocked ventilation slots can cause overhe...

Страница 7: ...ards and safety requirements Repairs should only be carried out by qualified persons using original spare parts Failure to do so may result in considerable danger to the operator PERSONAL SAFETY Cloth...

Страница 8: ...changes and when changing attachments such as air hoses tools Always use the correct type of tool for the operation to be carried out Never use the air compressor if any part of the unit is damaged A...

Страница 9: ...ank drain tap 5 Castors 6 Safety valve not shown 7 Tank pressure gauge 8 Front handle 9 Pressure switch 10 On Off button red colour 11 Outlet pressure gauge 12 Air outlet nitto style socket 13 Outlet...

Страница 10: ...HEELS To attach the caster wheels to the bracket located on the bottom of the tank 1 Undo the nut and remove the washer 2 Push through the bracket and replace the washer 3 Tighten the nut Pic 1 WHEELS...

Страница 11: ...he red ON OFF switch on top of the pressure switch AIR FILTER The supplied air filter must be used Failure to do so may result in irreparable damage and will void the warranty Pic 3 To install 1 Caref...

Страница 12: ...nitial pump up stage has finished you can use the compressor This compressor has a maximum pressure of 10 bar Always regulate the outlet air pressure to match your air tool Different air tools require...

Страница 13: ...6 Slowly open the tank drain tap see page 16 This allows excess air and moisture water to vent 7 Leave the tank drain tap open This allows any moisture to drain while the air compressor is stored NOTE...

Страница 14: ...ever up to horizontal NOTE Remember to seal the drain tap before starting the compressor Drain Tap Sealed OR To close and seal push lever up Right or left Drain tap opened un sealed AIR FITTING Pic 11...

Страница 15: ...alve 1 95 BRC95OWV 10 Wheel Set 2 95 STWH 11 Drain Tap 1 95 BRC95DT 12 Caster Wheel 1 95 STCW Part Description Qty SMG Part No 14 Handle 1 95 STDDH 15 Unloading Tube Set 1 95 SXCM27550323UT 17 Pressur...

Страница 16: ...and the Yellow and Black Diagonal Package Design are all trademarks of the Stanley Black Decker Inc or an affiliate thereof and are used under license Product manufactured and distributed by Smart Ma...

Отзывы: