background image

6

IMPORTANT OPERATION / MAINTENANCE NOTES

Now that your Stanley Solid Fuel Stove is installed and no doubt you are looking forward to many comforts it
will provide, we would like to give you some tips on how to get the best results from your stove.

1. We would like if you could take some time to read the operating instructions/hints, which we are 

confident, will be of great benefit to you.

2. Do not burn fuel with a high moisture content, such as a damp peat or unseasoned timber.  This will 

only result in a build up of tar in the stove and in the chimney.

3.

IMPORTANT: 

The first few fires should be relatively small to permit the refractory to set proper

ly and season the stove. During these firings it is recommended to ventilate the room as an 
unpleasant (not toxic) odour may be emitted as the paint is completing curement.

4. Inspect the flue-ways of the stove weekly and ensure that there are no blockages.  Check flue

ways before lighting especially after a shut down period.  Please see chimney cleaning section.

5. Before loading fresh fuel into the firebox, riddle fully to remove all ashes. This will allow better and 

cleaner burning.  See Re-Fuelling section.

6. Never allow a build up of ashes in the ash pan, as this will cause the grate to burn out prematurely.  

Empty the ashpan when refuelling.

7. Avoid slow burning of damp or unseasoned fuel as this will result in tarring flue ways and chim-

ney i.e. peat or timber.

8. Allow adequate air ventilation to ensure plenty of air for combustion.

9. Do not burn rubbish/household plastic.

10. Do not operate the stove with the ash-door open as this will over heat the unit causing unnecessary 

damage.  

11. Clean the chimney at least twice a year.

12. Burning soft fuels such as timber and peat will stain the glass.  Regular cleaning will prevent 

permanent staining.  Clean with soapy water when cool.

13. Keep all combustible materials a safe distance away from unit, please see section for clearances

to combustibles.

14. Never use aerosol spray near the appliance when it is in operation.

15. For safety reasons never leave children or the elderly unaccompanied while stove is in use.  Use a 

fire guard.

16. Avoid contact with the appliance when in use as stove reaches very high operating temperatures.

17. This appliance should be regularly maintained by a competent service engineer.

FUEL CALORIFIC VALUES - SOLID FUELS

Anthracite 25-50mm

C.V.:  8.2kW/Kg 

14,000 BTUs/lb

House Coal 25-75mm  

C.V.: 7.2kW/Kg 

12,000 BTUs/lb

Timber - Firebox size

C.V.:  5.0kW/Kg 

8,600 BTUs/lb

Peat Briquettes

C.V.:  4.8kW/Kg

8,300 BTUs/lb

Содержание Oisin

Страница 1: ...ld be supervised at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled When using the boiler stove in situations where chil...

Страница 2: ...ion HRV 10 14 Location 11 15 Clearance to Combustibles 11 16 Floor Protection 11 17 Plumbing 12 18 Water Pipe Locations 12 19 DHW System Domestic Hot Water 12 20 Safety Valve 13 21 Direct Domestic Cyl...

Страница 3: ...Chimney Cleaning 16 41 Glass Cleaning 17 42 Vitreous Enamel Cleaning 17 43 Cleaning a Matt Black Senotherm Stove 17 44 Change Rope Seals 17 45 Prolonged Periods of Non Use 17 46 Fire Safety 18 47 Gla...

Страница 4: ...lled as per the requirements of the manual Failure to comply with the Installation requirements or Building Regulations will void your warranty Waterford Stanley reserve the right to replace any part...

Страница 5: ...g Regulations to have a carbon monoxide alarm fitted to any room with a solid fuel appliance Location 10 Clearance to combustible materials must be adhered to as described in the Clearance to Combusti...

Страница 6: ...allow a build up of ashes in the ash pan as this will cause the grate to burn out prematurely Empty the ashpan when refuelling 7 Avoid slow burning of damp or unseasoned fuel as this will result in t...

Страница 7: ...and use appropriate protective equipment Metal Parts When installing or servicing this stove care should be taken to avoid the possibility of personal injury IMPORTANT WARNING This stove must not be i...

Страница 8: ...date should be removed before connecting this appliance If con necting to an existing chimney with a flue diameter of more that 8 it is recommend to line the flue using a suitable stainless steel flu...

Страница 9: ...o provision for closure The effective free area of any vent should be ascertained before installation The effect of any grills should be allowed for when determining the effective free area of any ven...

Страница 10: ...with the manufactur er s instructions and relevant standards As there is currently no standard for Ducted Combustion Air Supply this does not fall within the remit for HETAS product approval Responsi...

Страница 11: ...ss through walls or partitions constructed of combustible materials provided the connector is either listed for wall pass through or is routed through a device listed for a wall pass through and is in...

Страница 12: ...DEL ONLY The DHW Model must be connected to a gravity system Care should be taken to ensure that the domestic hot water installation is correctly installed and that it complies with all relevant codes...

Страница 13: ...ndirect cylinder fixed in an upright position recommended for hot water storage and it should be connected to the boiler by 28mm diame ter flow and return piping The pipes should not exceed 7 8 meters...

Страница 14: ...t and burn rate rotate the spin valve clockwise until fully closed You will soon learn spin valve settings to best suit your requirements See Fig 16 Fig 16 Note The controls may become hot when the st...

Страница 15: ...ing checks described previously have been carried out correctly and that the chimney has been swept clean is sound and free from any obstructions As part of the stoves commissioning and handover the i...

Страница 16: ...RHS of the baffle can pass below the fixing rib on the RHS panel thus allowing the baffle drop into the firebox and be removed from the stove lf the baffle is distorted can t be removed as described a...

Страница 17: ...cleaned when cool and cleaned with a non abrasive cloth using warm soapy water For stubborn deposits a grade 0 steel wool can be used whilst tak ng care not to scratch the glass with any coal ash dep...

Страница 18: ...c turers instructions Provision of an alarm must not be considered a substitute for either installing the appliance correctly or ensuring regular servicing and maintenance of the appliance and chimney...

Страница 19: ...XX 16 BACK BRICK H00002AXX 17 SERIAL NUMBER PLATE N00234BXX 18 DATA PLAQUE N00440AXX 19 GRATE SUPPORT PLATE Q00001BXX 20 TOP BAFFLE Q00003AXX 22 FIRE FENCE Q00005AXX 23 FIRE FENCE RETAINER Q00006AXX 2...

Страница 20: ...Rev 008 YS 280417 Item No N00002AXX 20 Manufactured by Waterford Stanley Ltd Unit 401 403 IDA Industrial Estate Cork Road Waterford Ireland Tel 051 302300 Fax 051 302315...

Отзывы: