Page 6 Section 3
Installation
MSD SABER SERIES SHEARS
INTERNAL ROTATION
CONTROL SYSTEM
INSTALLATION
if equipped
BEFORE GETTING STARTED
1.
Have the Parts Catalog for the shear and the
installation manual on hand for reference. The parts
information for the Internal Rotation Control System
is included in it.
2.
Check if the following items exist on the base
machine:
a. A preferred control switch other than the
foot switch provided (see Foot Pedal Switch Installa-
tion).
b. One -8 (1/2” SAE JIC type) adapter to tap
into base machine reservoir or return line.
c. One -8 (1/2” SAE) hydraulic line plumbed
from the base machine’s hydraulic return to the end
of the boom (if the shear is mounted in place of the
stick) or the stick if the shear is mounted in place of
the bucket.
d. One 15 amp circuit breaker or fuse.
ELECTRICAL INSTALLATION
INTERNAL ROTATION
CONTROL SYSTEM
if equipped
LaBounty provides a three-position foot switch with
the Internal Rotation Control System. Alternative
types of switches may be used in place of the pro-
vided foot switch, if preferred. Contact your LaBoun-
ty dealer for information on operating the control
valve. Any of the following can be used:
a.
Joystick handle equipped with a single
pole/double throw momentary three-position rocker
switch;
b. Two joystick handles each equipped with a
single pole/single throw momentary rocker switch or
push button switch;
c. a single pole/double throw three-position
momen-tary toggle switch mounted to the control
lever with a fabricated bracket.
INSTALLATION
1.
Place the foot switch or other preferred control
switch inside the cab in a convenient location for
operating.
2.
Route the electrical cord with the plug up the
boom (and stick if the shear replaces the bucket).
Secure the cord to an existing hydraulic line using
tie straps. Attach the green wire of this cord to the
base machine chassis to ground the system.
3.
Run a 14-gauge wire from the base machine’s DC
voltage power supply and connect it to a 15-amp
circuit breaker fuse. The power source should be
accessory side or a similar source that provides volt-
age only when the starter key switch is in the “ON”
position, and should have a 5-amp minimum rating.
4.
Connect a 14-gauge wire from the circuit breaker
or fuse to the red wire of the electrical cord running
up the boom to the electrical plug. Connect another
14-gauge wire from the circuit breaker or fuse to
this red wire of the electrical cord coming from the
foot switch. The red wire from the electrical plug
and the red wire from the foot switch can be con-
nected.
5.
Connect the black wire from the boom cord to
the black wire from the foot switch cord. Connect
the white wires in the same way. The green wire
from the foot switch cord will not be used.
To prevent electrical shock, short, or accidental
start-up, do not connect to the power source
until the entire system is installed.
Make sure to complete all installation procedures de-
scribed in this section before starting the machine.
Operating the shear before proper installation is
complete may cause damage to the base machine.
NOTICE
Содержание MSD 1000
Страница 1: ...MSD Saber Series Shears Part Number 512141 Safety Operation Maintenance Manual...
Страница 6: ...TABLE OF CONTENTS...
Страница 20: ......
Страница 30: ...Page 10 Section 3 Installation MSD SABER SERIES SHEARS...
Страница 38: ...Page 8 Section 4 Operation MSD SABER SERIES SHEARS...
Страница 117: ...512141 ver 6 2012 The STANLEY and LABOUNTY names and logos are registered trademarks of Stanley Infrastructure Solutions...