Table 4. Magic Force/Magic Swing Configuration Codes -- Motor 1 Continued
Index
Min.
Value
Max.
Value
Description
Defaults
Low
Energy
Full
Energy
11
00
04 Safety Logic. INDEX 11 - 00 to 15
00 = Sensor
01 = Sentrex
02 = Carpet
03 = Carpet 12 Sec.
04 = Non-Monitored Bi-Fold
05 = Monitored DM & OHP. ACT, STL & SAF, both
single & pair
06 = Monitored DM & OHP Dual Egress. STL, ACT,
STL & SAF
07 = Monitored OHP & Photobeam. SAF &
Photobeam
08 = Monitored DM ACT. ACT both single & pair
09 = Monitored OHP Bi-Fold. SAF
10 = Monitored DM. ACT & STL both single & pair
11 = Two OHP Monitored Bi-fold. SAF, Bi-Fold/Swing
12 = Monitored Hub Based Sensors. ACT & STL
13 = Swing-Guard T
14 = Monitored DM Stall & OHP both single and pair.
STL & SAF
15 = Monitored DM Stall & OHP Dual Egress. STL & SAF
00
00
12
00
01 2S Operation, 00 = OFF, 01 = ON
00
00
13
01
60 Obstruction Time (percent) (60 = 1.5 seconds)
20
20
14
20
60 Open Acceleration Slope
60
60
15
20
40
Open Braking Slope
35
35
16
00
50 Operate Delay. Motor 1 (0.1 sec. increments: 5.0 sec. max.)
00
00
17
00
01
No Reverse on Obstruction (00 Off, 01 On)
NA
NA
18
00
50
Lock Delay (0.1 sec. increments, 5.0 sec. max.)
00
00
19
00
01
Manual Mode sensor override (00 Off, 01 On)
00
00
ABBREVIATIONS:
DM - Door Mounted Sensors
OHP - Overhead Presence Sensor
ACT - Activation Side Presence Sensor
STL - Stall Presence Sensor