MC521 PRO Control Box
50 Document # 204090 REV D • www.stanleyaccess.com • 1.800.7.ACCESS
Cop
yr
ight 2017, S
tanley Ac
cess T
echnologies, LL
C. All rights r
es
er
ved. R
epr
oduction
in whole or in p
ar
t without the expr
ess wr
itt
en permission o
f S
tanley is pr
ohibit
ed.
03.23.2017
Values shown as grayed out do not affect motion of the door and may need to be adjusted to suit the application
Attachment 10
Table 4 Recommended Values for Single In-Swing Doors
Index
Description
Light Weight Door (100lbs)
Heavy Weight Doors (350lbs)
Low Energy
Full Energy
Low Energy
Full Energy
00
Open speed, revolutions per second
10
35
06
25
01
Check speed, revolutions per second
04
04
04
04
02
Stall speed, percent of PWM counts
See Attachment 11
03
Open check
40
45
25
45
04
Magic Touch sensitivity
00
00
00
00
05
Magic Touch hold open time
HH=55
KP=22
HH=40
KP=16
HH=55
KP=22
HH=40
KP=16
06
Hold-open delay
HH=55
KP=22
HH=15
KP=06
HH=55
KP=22
HH=15
KP=06
07
Open torque, percent of full torque
09
75
11
75
08
Check torque, percent of full torque
20
40
25
75
09
Stall torque, percent of full torque
25
25
25
25
10
Open Check Boost
05
08
04
10
11
Safety Logic
00
00
00
00
12
2S Operation
00
00
00
00
13
Obstruction Time
HH=50
KP=20
HH=50
KP=20
HH=50
KP=20
HH=50
KP=20
14
Open Acceleration Slope
60
60
60
60
15
Open Braking Slope
20
20
35
35
16
Delay of door motion. Motor 1
00
00
00
00
17
No Reverse on Obstruction
00
NA
00
NA
18
Lock Delay
00
00
00
00
19
Manual Mode sensor override
00
00
00
00
31
Off Mode
00
00
00
00
32
Lock Logic
01
01
01
01
37
Unlock Time
10
10
10
10
HH = Hand Held
KP = Key Pad