6 Installation of the boiler pellet stove
Before installing, please perform the following steps:
·
Upon receipt, check that the product is complete and that there are no signs of damage. Any damage or defects should be
checked for prior to installing the product. If there are defects please notify Waterford Stanley service department.
·
The stove is equipped with four adjustable height feet at the base which allow for a simple adjustment when installed on a
unlevel surface.
Figure 8
– Adjustable feet
·
Remove the instruction manual from the package and hand it over to the client.
·
Connect the flue, the K1200 requires an 80mm diameter flue connection, while the K1700 & K2300 require a
100mm diameter flue from the flue outlet to a cleaning Tee , it should be connected to a 125mm flue/ chimney
liner.
·
If a pipe is used for combustion air inlet from the outside, it shall be no longer than 60cm horizontally, there
should be no bends or offsets.
·
Perform the hydronic installation
·
Connect the 230VAC power cable to a grounded socket.
·
The surface of the stove where the hot air outlet is located must be facing the area to be heated.