HP210
User
Manual ◄ 11
CONTROLS
HP210 can provide two 5 GPM/20 LPM circuits (up to 2000
psi/140 bar) or one 10 GPM/40 LPM circuit (up to 2000
psi/140 bar).
HP210BA and HP210BBA CE models can provide two 4
GPM/15 LPM circuits (up to 2000 psi/140 bar) or one 8
GPM/30 LPM circuit (up to 2000 psi/140 bar).
STARTUP
1. Toggle both Flow Switches to the “FLOW OFF”
position.
Note: HP210 will not start unless the Flow Switches are
in the "FLOW OFF" position.
2. Pull the choke knob out
3.
Select the desired flow using the Flow Selector Knob.
4. Turn the Ignition Switch to the “START” position. After
the engine starts, release the switch.
5. Gradually push in the choke knob as the engine begins
to idle smoothly.
6. Allow the engine to warm up.
7. Connect hoses and the tool.
8.
Toggle the Flow Switches to the desired flow for each
circuit.
CHANGING CIRCUIT FLOW
1. Toggle the Flow Switches to the “FLOW OFF” position.
2.
Select the desired circuit flow using the Flow Selector
Knob.
3.
Toggle the Flow Switches to the desired flow for each
circuit.
SHUTDOWN
1. Toggle the Flow Switches to the “FLOW OFF” position.
2. Allow the engine to idle for approximately one minute.
3. Turn the Ignition Switch to the “OFF” position.
COLD WEATHER STARTUP
Hydraulic fluid becomes thicker in cold weather. STANLEY
recommends that the engine be run at a low idle (5
GPM/20 LPM setting) long enough to bring the fluid
temperature up to a minimum of 50°F/10°C. Allow the
hydraulic fluid to circulate through the tool hoses until they
are warm.
Once the hydraulic oil is warm, you may operate the HP210
as normal.
OPERATION
Ignition Switch
Flow Switches
Female Hydraulic
Hose Fitting
Throttle / Flow
Selector Knob
Female Hydraulic
Hose Fitting
Male Hydraulic
Hose Fitting
Male Hydraulic
Hose Fitting