background image

5

Fig.6

Dimensions 

A

B

C

D

E

F

G      H         I

Metric (mm)

660

648

430

541

485

324

165   697     495

NOTE:

Dimensions stated below may be subject 

to a /- variation.

SPECIFICATION

Metric

Depth

495mm

Flue Outlet

152mm

Fire Door Size

455x230mm

Log Size

406mm

COAL, ANTHRACITE, WOOD SYNTHETIC LOGS,

OR OTHER FUELS.  “Never use gasoline” gasoline

type lantern fuel, kerosene, charcoal lighter fluid or

similar liquids to start or ‘freshen up’ a fire in this

heater.  Keep all such liquid well away from the

heater at all times.  Operate stove only with fuelling

door and ashpit doors closed.  This heater is hot

whilst in operation.  Keep children, clothing and fur-

niture a safe distance away.

LOW / SLUMBER BURN

To achieve an overnight or a low burn rate, close the

air wash slider fully by sliding the lever left using the

ashpan tool and turn the primary air control knob to

setting 0.

PRIMARY AIR CONTROL

Fig.7

Setting 0:

Overnight Burning

Setting 1:

Closed 

Setting 2:

Slow burning

Setting 3:

Medium burning

Setting 4:

Maximum Heat

OPERATING INSTRUCTIONS

Содержание GRAINNE

Страница 1: ...s appliance is hot while in operation and retains its heat for a long period of time after use Children aged or infirm persons should be supervised at all times and should not be allowed to touch the...

Страница 2: ...12 Floor Protection 4 13 T echnical Data 4 14 Specification 5 15 Operating Instructions 6 16 Low Slumber Burn 6 17 Primary Air Control 6 18 Recommended Fuels 6 19 Important Notes 7 20 Lighting 8 21 D...

Страница 3: ...when the length of the horizontal section should not exceed 150mm In order to minimise flue resistance and to make sweeping easier it is recommended to use 2 x 45 o bends rather than a 90 o bend The...

Страница 4: ...requirement for this appliance use the following equation a total free area of at least 550mm 2 per kW of rated output above 5kW shall be provided If there is another air using appliance fitted in the...

Страница 5: ...It is recommended that this appliance is sited next to and on a non combustible surface A minimum all round clearance of 100 mm will allow air circulation and not impede the performance of the stove F...

Страница 6: ...en up a fire in this heater Keep all such liquid well away from the heater at all times Operate stove only with fuelling door and ashpit doors closed This heater is hot whilst in operation Keep childr...

Страница 7: ...at all times Operate the stove only with the fuelling door closed except for re fuelling Fig 8 OPEN When burning coal timber or peat CLOSE When burning anthracite and smokeless fuels WARNING DO NOT OB...

Страница 8: ...pen for long periods as this will over heat the unit causing unnecessary damage Close the ash door between removing and replacing the ashpan 9 Clean the chimney at least twice a year 10 Burning soft f...

Страница 9: ...the fire door and add more kindling of a larger size to sustain the fire Close the firedoor Do not operate this appliance with the firedoor open 8 Never use inflammable liquid i e gasoline petrol para...

Страница 10: ...e hob before relight ing the fire TO REPLACE DAMAGED GRATE OR GRATE BAR Remove the front brick the back brick all the left hand side bricks and both small right side bricks from the stove taking care...

Страница 11: ...n be carefully used on the vitreous enamel 3 Use only products recommended by the Vitreous Enamel Association these products carry the Vitramel label 4 DO NOT USE ABRASIVE PADS OR OVEN CLEANSERS CONTA...

Страница 12: ...rmostat 23 Front Brick 24 Back Brick 25 Side Back Brick 26 Left Front Brick 27 Right Front Brick 28 Side Brick No 1 29 Side Brick No 2 30 LH Front Brick No 2 31 LH Fire Door 32 RH Fire Door 33 Ash Pit...

Отзывы: