background image

DONARD 60K GAS FIRED

To ensure safety, satisfaction and reliable service, this Cooker should be installed by a suitably qualified
and competent person. 
The provision of a Central Heating facility, requires that the hot water systems
involved, conform fully to good plumbing practice and established standards.

INSTALLATION AND OPERATING INSTRUCTIONS

TO BE LEFT WITH END USER

(SUPER STAR 60K GAS COOKER)

Содержание DONARD 60K

Страница 1: ...talled by a suitably qualified and competent person The provision of a Central Heating facility requires that the hot water systems involved conform fully to good plumbing practice and established sta...

Страница 2: ...tion 10 26 Clearance to Combustibles 11 27 Gas Connection 12 28 Heating 12 29 Water Pipe Fittings 13 30 Plumbing Drawings 13 31 Safety Valve 14 32 S Plan Wiring Diagram 14 33 By Pass Loop 15 34 Airing...

Страница 3: ...NO 56 Condensation 21 57 Ovens 21 58 Hotplate 21 59 Servicing Cleaning of the Appliance 21 60 Chimney Cleaning 22 61 Burner Removal 22 62 Wiring Diagram 23 63 Wiring Diagram 24 64 Trouble Shooting Gu...

Страница 4: ...e 6 Hob 7 Towel Rail 8 Fire Door 9 Burner Door 10 Main Oven Door 11 Simmer Oven Door 12 Base Frame 13 Hotplate 14 Simmer and Cleaning Plate 15 Boiler Thermostat 16 Oven Thermostat 17 Green Neon Indica...

Страница 5: ...CIFICATION This appliance has been tested and approved in accordance with the Gas Appliance Directive 90 396 EEC the Low Voltage Directive 72 23 EEC and the Electromagnetic Compatibility Directive 89...

Страница 6: ...in accordance with the regulations in force and only used in a well ventilated location Read the technical instructions before installing this appliance Read the user s instructions carefully before l...

Страница 7: ...the appliance completely unplug from the mains socket Always ensure that this socket is easily accessible and close to the appliance Persons in charge of this appliance should be aware of this socket...

Страница 8: ...ve chimney for gas is one that is straight avoid offsets and terminate an approved low resistance flue terminal Fig 2 Fig 3 Fig 5 Fig 6 SEALING This cooker and flue system operate under a positive pre...

Страница 9: ...nforming to B S 4543 and B S 5440 a galvanised finish is not suitable Clay flue linings conforming to B S 1181 Pre cast concrete chimney blocks incorporated into the building structure It is particula...

Страница 10: ...outlet Removal of debris should be facilitated by the provision of an access door The void should have a depth of not less than 250mm 10 below the appliance connection The combustion products from thi...

Страница 11: ...d in such a manner as not to impair the weather resistance of the cavity Joints between air vents and outside walls should be sealed to prevent the ingress of moisture Existing air vents should be of...

Страница 12: ...lable to order see fig 11a When bringing the kitchen units up to the sides of the cooker hob leave a 10mm 3 8 gap between the hob and adjacent units this gap can be masked by fitting a filler strip up...

Страница 13: ...des of practice see installation section If this appliance is being connected to an existing system it is strongly recommended to check the following a That the system is sound b That pipework is adeq...

Страница 14: ...and should conform to the current editions of the following or their equivalent 1 1 Ferrous Materials BS 4127 Stainless steel tubes BS 1387 Steel tubes BS 1740 Steel pipe fittings BS 6956 Jointing Ma...

Страница 15: ...fitted to the primary flow pipe adjacent to boiler connection ensuring that any discharge will not create a hazard to occupants or cause damage to electrical components or property BUNGALOW FULLY PUM...

Страница 16: ...from the cooker to allow correct water circulation for the pump and to prevent condensation forming in the boiler This should be balanced A heat sink radiator must be installed in addition to the By P...

Страница 17: ...mperature falls below 60 C the pipe thermostat will de activate the circulating pump and allow the cooker to operate see fig 20 27 Wiring Diagram If a second optional pipe thermostat is used see S Pla...

Страница 18: ...itched off Test the whole gas installation including the meter for soundness and purge in accordance with B S 6891 U K and I S 813 I E Purge not to exceed 50 mbar 10 Check the burner for leaks using a...

Страница 19: ...urning the baffle control knobs with the tool provided to the required position There are three main heating modes as follows determined by the positioning of the baffles which are operated by rotatin...

Страница 20: ...eratures are achieved but will vary depending on central heating conditions SUMMER SETTING For summer use and lowest Boiler Output use setting C When using the oven in this position turn the oven ther...

Страница 21: ...or the vitreous enamel may be permanently discoloured Jam and preservatives containing sugar can permanently damage the vitreous enamel 3 Keep a damp cloth to hand while cooking to wipe up any spills...

Страница 22: ...amel Association these products carry the Vitramel label 6 In the oven spills and fat splashes are carbonised at high temperatures occasionally brush out with a stiff brush The shelves can be soaked a...

Страница 23: ...be extended as time goes by if there is little sign of deposits Fig 34 Fig 35 Fig 36 Fig 33 4 Slacken the unions on both sides of the base frame and disconnect the tube from the air pressure switch 5...

Страница 24: ...23...

Страница 25: ...24...

Страница 26: ...SHOOTING GUIDE 3 Check that the start gas valve is energised and is opening during safety time 4 If necessary change control box Burner starts flame established control box locks out displaying symbol...

Страница 27: ...26 Waterford Stanley Bilberry Waterford Ireland Telephone 051 302300 Facsimile 051 302375 Rev 003 DP 020820...