CT04 User
Manual ◄ 9
HTMA REQUIREMENTS
TOOL CATEGORY
HYDRAULIC SYSTEM
REQUIREMENTS
TYPE I
TYPE II
TYPE III
TYPE RR
FLOW RATE
4–6 gpm
(15–23 lpm)
7–9 gpm
(26–34 lpm)
11–13 gpm
(42–49 lpm)
9–10.5 gpm
(34–40 lpm)
TOOL OPERATING PRESSURE
(At the power supply outlet)
2000 psi
(145–155 bar)
2000 psi
(138 bar)
2000 psi
(138 bar)
2000 psi
(138 bar)
SYSTEM RELIEF VALVE SETTING
(At the power supply outlet)
2100–2250 psi
(145–155 bar)
2100–2250 psi
(145–155 bar)
2100–2250 psi
(145–155 bar)
2200–2300 psi
(145–155 bar)
MAXIMUM BACK PRESSURE
(At tool end of the return hose)
250 psi
(17 bar)
250 psi
(17 bar)
250 psi
(17 bar)
250 psi
(17 bar)
Measured at a max. fluid viscosity of:
(At min. operating temperature)
400 ssu*
(82 centistokes)
400 ssu*
(82 centistokes)
400 ssu*
(82 centistokes)
400 ssu*
(82 centistokes)
TEMPERATURE
Sufficient heat rejection capacity
to limit max. fluid temperature to:
(At max. expected ambient temperature)
140 °F
(60 °C)
140 °F
(60 °C)
140 °F
(60 °C)
140 °F
(60 °C)
Min. cooling capacity
at a temperature difference of
between ambient and fluid temps
3 hp
(2.24 kW)
40 °F
(22 °C)
5 hp
(3.73 kW)
40 °F
(22 °C)
7 hp
(4.47 kW)
40 °F
(22 °C)
6 hp
(5.22 kW)
40 °F
(22 °C)
NOTE:
Do not operate the tool at oil temperatures above 140 °F (60 °C). Operation at higher temperatures can cause operator
discomfort at the tool.
FILTER
Min. full-flow filtration
Sized for flow of at least:
(For cold temp. start-up and max. dirt-holding
capacity)
25 microns
30 gpm
(114 lpm)
25 microns
30 gpm
(114 lpm)
25 microns
30 gpm
(114 lpm)
25 microns
30 gpm
(114 lpm)
HYDRAULIC FLUID
100–400 ssu*
100–400 ssu*
100–400 ssu*
100–400 ssu*
Petroleum based
(Premium grade, anti-wear, non-conductive)
VISCOSITY
(At min. and max. operating temps)
(20–82 centistokes)
NOTE:
When choosing hydraulic fluid, the expected oil temperature extremes that will be experienced in service determine
the most suitable temperature viscosity characteristics. Hydraulic fluids with a viscosity index over 140 will meet the
requirements over a wide range of operating temperatures.
*SSU = Saybolt Seconds Universal