background image

77-030

MOISTURE METER

T

+

T

+

BUL

SL

SI

Caution: The electrode pins are very sharp. 

Handle instrument carefully. Keep pins covered 

when not in use.

Replaceable Electrodes

Flip-Off Protective Cap with Battery and  

 

 

Resistance Test sockets

On/Off Switch

Rubber Hand Grips

Backlit LCD Screen

Stanley Moisture Meter

The Stanley Moisture Meter detects moisture in 

wood and common building materials including, 

but not limited to, drywall, plaster, concrete and 

cement board. 

A

B

B

C

D

E

T

+

Low Battery 

Icon

Building 

Materials 

Scale

Wood Scale

Ready

SPECIFICATIONS

Display 

LCD with dual measuring  

 

scales

 

With green Backlight

Range, Wood 

6 to 44%      ± 2%

Range, Building Materials  0.2 to 2.0%  ± 0.1%

Auto Power Off 

3 minutes

Operating Temperature 

32° to 122°F (0 to 50°C)

Operating % Humidity 

80% Max.  

 

Relative Humidity 

Power Supply 

(3) CR-2032 Button Cells

Electrode Pins 

(2) 0.3” (8mm),  

 

 

Replaceable

Accessories 

Carry Pouch w/ Belt Clip

OPERATING INSTRUCTIONS

Use

1.  Slide power switch to “ON” position.
2.  Lift protective cap 

1

, then pivot to position 

2

3.  Press electrodes into the material to be tested.
  A.  Press carefully, but as deeply as possible to get  

    good contact.
  B.  In wood, take measurements across the grain.
  C.  Take several readings to get a better idea of the  

    general moisture content of the material.

T

+

1

2

T

+

Wood Grain

Testing Batteries:

1.  With the protective cap in place over electrodes    

  and unit power “ON”, rotate cap until battery icon  

  aligns with arrow.
2.   Push down on cap. LCD should display 44%  

 

  reading on “Wood” scale.
If the display is not at 44% or the battery icon appears 

on the LCD, replace the batteries.

Testing Moisture Scale Accuracy:

1.   With the protective cap in place over electrodes 

  and unit power “ON”, rotate cap until the “T”  

 

  aligns with arrow.

T

+

T

+

2.   Push down on cap. LCD should display 27.5% ±2%  

  reading on “Wood” scale.
If the reading is not within the limits, the unit may 

require repair.

Replacing Batteries:

 

Push in 

1

, Then lift door 

2

3

 push in on tab and battery 

will pop up.

T

+

1

2

T

+

3

©2009 THE STANLEY WORKS:

www.stanleyworks.com 

Stanley Tools Product Group, Stanley Europe

Egide Walschaertsstraat 14-16, 2800 Mechelen, Belgium

(01/09) Issue 1

50301 X

WARRANTY

One Year Warranty

Deficient products will be repaired or replaced, at 

Stanley Tools’ option, if sent together with proof of 

purchase to:

Stanley UK Sales Limited,
Gowerton Road,
Brackmills,
Northampton
NN4 7BW

This Warranty does not cover deficiencies caused 

by accidental damage, wear and tear, use other than 

in accordance with the manufacturer’s instructions 

or repair or alteration of this product not authorized 

by Stanley Tools. Repairs or replacement under 

this Warranty does not affect the expiry date of the 

Warranty. 
To the extent permitted by law, Stanley Tools shall 

not be liable under this Warranty for indirect or 

consequential loss resulting from deficiencies in this 

product.
This Warranty may not be varied without the 

authorization of Stanley Tools.
This Warranty does not affect the statutory rights of 

consumer purchasers of the product.
This Warranty shall be governed by and construed in 

accordance with the laws of England and Stanley Tools 

and the purchaser each irrevocably agrees to submit to 

the exclusive jurisdiction of the courts of England over 

any claim or matter arising under or in connection with 

this Warranty.

IMPORTANT NOTE:

The customer is responsible for the correct use and 

care of the instrument. Moreover he is completely 

responsible for checking the job along its prosecution, 

and therefore for the calibration of the instrument. 

Calibration and care are not covered by Warranty.

Subject to change without notice

77-030

Feuchtigkeitsmesser

T

+

T

+

BUL

SL

SI

Achtung: Die Elektrodenkontakte sind sehr  

scharf. Bitte gehen Sie mit dem Gerät vorsichtig 

um. Wenn es nicht benutzt wird, sollten die 

Kontakte abgedeckt werden.

Auswechselbare Elektroden

Flip-Off Schutzkappe mit Batterie und  

 

 

Widerstandsteststeckdosen

An-/Aus-Schalter

Gummihandgriffe

Hintergrundbeleuchtete LCD-Anzeige

Stanley Feuchtigkeitsmessgerät

Das Stanley Feuchtigkeitsmessgerät ermittelt 

Feuchtigkeit in Holz und verbreiteten Baumaterialien 

einschließlich, jedoch nicht begrenzt auf, 

Trockenmauern, Putz, Beton- und Zementplatten.

  

A

B

B

C

D

E

T

+

Symbol für 

niedrigen 

Batteriestand

Anzeige für 

Baumaterialien

Holzanzeige

TECHNISCHE DATEN

Display 

LCD mit dualen  

 

 

Maßanzeigen

 

Mit grüner   

 

 

Hintergrundbeleuchtung

Bandbreite, Holz 

6 bis 44%      ± 2%

Bandbreite, Baumaterialien 

0,2 bis 2,0%      ± 0,1%

Automatisches Abschalten 

3 Minuten

Betriebstemperatur 

0 bis 50°C

Betriebliche % Feuchtigkeit     80% max. relative  

 

 

Feuchtigkeit 

Stromversorgung 

(3) CR-2032 Knopfzellen

Elektrodenkontakte 

(2) (8mm), Austauschbar

Zubehör 

Tragebeutel mit 

 

 

 

Gürtelklemme

BETRIEBSANLEITUNG

Inb

etri

ebn

ahm

e

1. 

Sch

ieb

en 

Sie

 de

n N

etz

sch

alte

r in

 di

e „

An“

-Po

siti

on.

2. 

Neh

men

 Si

e d

ie 

Sch

utz

abd

eck

ung

 

1

 ab

 un

d d

reh

en 

Sie

  

 

das

 Ge

rät

 da

nn 

in 

Pos

itio

2

3. 

Drü

cke

n S

ie 

die

 El

ekt

rod

en 

in 

das

 zu

 pr

üfe

nde

 M

ate

ria

l.

 

A. 

Drü

cke

n S

ie 

die

 El

ekt

rod

en 

sor

gfä

ltig

, je

doc

h s

o ti

ef  

 

 

wie

 m

ögl

ich

 hi

nei

n, u

m e

ine

n g

ute

n K

ont

akt

 zu

  

 

 

 

erz

iel

en.

 

B. 

Neh

men

 Si

e b

ei H

olz 

die

 M

ess

ung

 qu

er z

ur  

 

 

 

Mas

eru

ng 

vor

 

C. 

Neh

men

 Si

e m

ehr

ere

 M

ess

ung

en 

vor

, u

m  

 

 

ein

en 

gen

aue

ren

 Üb

erb

lic

k ü

ber

 de

n a

llg

em

ein

en 

 

 

 

Flü

ssi

gke

its

geh

alt 

des

 M

ate

ria

ls 

zu 

erh

alte

n.

T

+

1

2

T

+

Übe

rpr

üfe

n d

er G

ena

uig

kei

t d

er 

Feu

cht

igk

eits

mes

sun

g:

1.  

Dre

hen

 Si

e d

ie 

Abd

eck

ung

, w

ähr

end

 si

ch 

die

se 

übe

r   

 

den

 El

ekt

rod

en 

befi

nde

t u

nd 

der

 N

etz

sch

alte

r d

es 

 

 

 

Ger

äte

s a

uf „

An“

 st

eht

, b

is 

das

 Sy

mbo

l „

T“ 

mit 

ein

em

  

 

Pfe

il a

ufle

uch

tet

.

2.  

Abd

eck

kap

pe 

hin

unt

er d

rüc

ken

. D

ie 

LCD

-An

zei

ge 

 

 

 

sol

lte

 27

,5%

 ±2

% a

uf d

er „

Hol

z“-

Anz

eig

e ze

ige

n.  

Wen

n d

er a

bzu

les

end

e W

ert 

sic

h n

ich

t in

ner

hal

b d

ies

es 

Ber

eic

hs 

befi

nde

t, d

ann

 m

uss

 da

s G

erä

t m

ögl

ich

erw

eis

rep

arie

rt w

erd

en.

T

+

1

2

T

+

3

©2009 THE STANLEY WORKS:

www.stanleyworks.com 

Stanley Tools Product Group, Stanley Europe

Egide Walschaertsstraat 14-16, 2800 Mechelen, Belgium

(01/09) Issue 1

50301 X

GARANTIE

Ein-Jahresgarantie

Defekte Produkte werden nach dem Ermessen von Stanley 

Tools repariert oder ersetzt unter der Bedingung, dass sie 

zusammen mit dem Kaufbeleg an folgende Adresse gesandt 

werden:

Stanley Bostitch GmbH

Bützgenweg  2

45239  Essen

Germany

Defekte, die durch zufällige Beschädigung, Verschleiß oder 

Verwendung entgegen den Anweisungen des Herstellers 

oder von Stanley Tools nicht genehmigten Reparaturen 

oder Veränderungen des Geräts entstehen, bleiben von 

der vorliegenden Garantie ausgeschlossen.  Reparaturen 

oder Ersatz unter der vorliegenden Garantie haben keinen 

Einfluss auf das Ablaufdatum der Garantie.

Im Rahmen der gesetzlichen Bestimmungen haftet Stanley 

Tools unter der vorliegenden Garantie nicht für indirekte oder 

Folgeschäden auf Grund von Defekten des vorliegenden 

Produkts.

Jede Änderung der vorliegenden Garantie bedarf der 

vorherigen Genehmigung von Stanley Tools.

Die vorliegende 

Garantie schmälert 

die im 

Verbrauchergesetz 

vorgesehenen Rechte des Käufers des Produkts nicht.

Die vorliegende Garantie untersteht und entspricht dem 

englischen Recht und Stanley Tools und der Käufer erklären 

unwiderruflich, sich bei Ansprüchen oder Streitigkeiten 

in Zusammenhang mit der vorliegenden Garantie der 

ausschließlichen Rechtsprechung der englischen Gerichte 

zu unterstellen.

WICHTIGE BEMERKUNG:

Korrekte Nutzung und Pflege fallen in die alleinige 

Zuständigkeit des Kunden. Weiter liegt es in der alleinigen 

Verantwortung des Kunden, das Gerät während der Arbeit 

zu prüfen und für die entsprechende Kalibrierung des 

Instruments zu sorgen. Kalibrierung und Pflege bleiben von 

der Garantie ausgeschlossen. 

Kalibrierung und Pflege bleiben von der Garantie 

ausgeschlossen.

Änderungen dürfen ohne vorherige Benachrichtigung 

vorgenommen werden.

T

+

Holzmaserung

T

+

Prü

fen

 de

r B

atte

rie

n:

1. 

Dre

hen

 Si

e d

ie 

Abd

eck

ung

, w

ähr

end

 si

ch 

die

se 

übe

r

 

den

 El

ekt

rod

en 

befi

nde

t u

nd 

der

 N

etz

sch

alte

r d

es 

 

Ger

äte

s a

uf „

An“

 st

eht

, b

is 

das

 Ba

tte

rie

sym

bol

 m

it  

 

 

ein

em

 Pf

eil 

aufl

euc

hte

t.

2.  

Abd

eck

kap

pe 

hin

unt

er d

rüc

ken

. D

ie 

LCD

-An

zei

ge 

 

 

 

sol

lte

 44

% a

uf d

er „

Hol

z“-

Anz

eig

e ze

ige

n.  

 

Wen

n d

as 

Dis

pla

y n

ich

t a

uf 4

4%

 st

eht

 od

er d

as 

Bat

ter

ies

ym

bol

 au

f d

er L

CD-

Anz

eig

e e

rsc

hei

nt, 

müs

sen 

die

 Ba

tte

rie

n e

rse

tzt

 w

erd

en.

Aus

wec

hse

ln 

der

 Ba

tte

rie

n: 

 

1

 hi

nei

ndr

ück

en,

 da

nn 

Tür

 

2

 an

heb

en,

 

3

 Sc

hei

be 

hin

ein

drü

cke

n u

nd 

die

 Ba

tte

rie

 tri

tt h

era

us.

Отзывы: