Stanford Research Systems
PS300 Series High Voltage Power Supplies
Remote Operation
3 – 14
Bit Name
Usage
0
OPC
Set by *OPC
1 unused
2
Query Error
Set by an output queue over
fl
ow
3
Recall Err
Set if a stored se ing is corrupt
4
Execution Err Set by an out-of-range parameter or
incomplete
command.
5
Command Err Set by a command syntax error or an
unrecognizable
command
6
URQ
Set by any key press
7
PON
Set by a power-on condition
This status byte is de
fi
ned by IEEE488.2 (1987) and is used primar-
ily to report errors in commands received over the communication
interface. Once set, the bits in this register stay set, and are cleared
when read or when a
*CLS
command is received.
If a bit in the standard status register is set, and the corresponding
bit in the standard status enable register is set, then the ESB bit in
the serial poll register is set.
If an error occurs due to an incomplete command, the following er-
ror messages will appear on the middle display:
Err6
Syntax Error Over GPIB
The command has an error in syntax or was unrecognizable.
This is the same error as seen in the Command Error (bit 5)
of the Standard Event Status Byte.
Err7
Illegal Parameter Entered Over GPIB
A parameter was set out-of-range, or a command could not
be completed because of an overload condition. This is the
same error seen in the Execution Err (bit 4) of the Standard
Event Status Byte.
Err8
GPIB Output Queue Full
The output queue over
fl
owed and was cleared. This could
be due to querying the instrument repeatedly and not
3.6.2 Standard Event Status Byte
3.6.3 GPIB Error Messages
Содержание PS355
Страница 4: ...Stanford Research Systems PS300 Series High Voltage Power Supplies Contents ii ...
Страница 10: ...Phone 408 744 9040 www thinkSRS com PS300 Series HighVoltage Power Supplies General Information viii ...
Страница 16: ...Stanford Research Systems PS300 Series High Voltage Power Supplies Instrument Overview 1 6 ...
Страница 22: ...Stanford Research Systems PS300 Series High Voltage Power Supplies Guide to Operation 2 6 ...
Страница 38: ...Stanford Research Systems PS300 Series High Voltage Power Supplies Remote Operation 3 16 ...
Страница 42: ...Stanford Research Systems PS300 Series High Voltage Power Supplies Troubleshooting 4 4 ...