background image

 

 

MS350 - Manual

 

 

AM150B 

Standby AB – standbygroup.se 

 

 

Pos 2 Stand-alone functions Norway

 

Connector P1

 

Pin  Function 

Standby 

Name 

Imax 

Recommended fuse 

Beacon left 

Y11+ 

6A 

 

Beacon right 

Y12+ 

6A 

 

Power supply for outputs 
(Y11+, Y12+, Y15+, Y16+, Y17+, Y18+) 

S13+ 

< 20A 

Common fuse max 
15A(see connection 
section) 

Power supply for outputs 
(Y11+, Y12+, Y15+, Y16+, Y17+, Y18+) 

S14+ 

< 20A 

 

Status ok loudspeaker 

Y15+ 

2A 

 

Status ok beacon left 

Y16+

2A

 

Status ok beacon right 

Y17+ 

2A 

 

Not used 

Y18+ 

2A 

 

- Loudspeaker left 

SP19- 

5A 

 

10 

+ Loudspeaker left 

SP110+ 

5A 

 

11 

+ Loudspeaker right 

SP111+ 

5A 

 

12 

- Loudspeaker right 

SP112- 

5A 

 

13 

Yelp US

 (horn-signal, edge trigged) 

 
Activate/deactivate the sound. The sound will automatically be 
deactivated after 10 seconds. Input X117 must be active to be 
able to use this function. 

X113+ 

< 20 mA  max 1A 

14 

Ground MS-350 

S114- 

10A 

 

15 

Yelp US

 (horn-signal, edge trigged) 

 
Activate/deactivate the sound. The sound will automatically be 

deactivated after 10 seconds. Input X117 must be active to be 
able to use this function. 

X115- 

< 20 mA  max 1A 

16 

Power Supply Amplifier 

S116+ 

10A 

10A 

17 

Wail US

 (continuous feed) 

 
Activates the sound AND the output Beacon. 

X117+ 

< 20 mA  max 1A 

18 

Beacon

 (continuous feed) 

X118+ 

< 20 mA  max 1A 

19 

Not used 

X119+ 

< 20 mA  max 1A 

20 

Not used 

X120+ 

< 20 mA  max 1A 

21 

Not used 

X121+ 

< 20 mA  max 1A 

22 

Air Horn

 (continuous feed) 

 
This sound has higher priority than all other sounds. 

X122+ 

< 20 mA  max 1A 

 

 

 

Содержание MS350

Страница 1: ...t consumption 500μA at standby mode Inputs 7 x 20mA active high 1 x 20mA active low Outputs 2 x 6A 4 x 2A Enclosure rating IP 54 Approvals Accoustic EMC T046Lu Swedish approval only valid together with two KSR350 4Ω 12V 16Ω 24V ECE R10 Included Installation The Control Unit can be installed as desired in the vehicle interior Due to the housing design the Control Unit can be variably attached and c...

Страница 2: ...d be fused with max 1A Pin 3 and 4 S13 and S14 should together be fused max 15A fuse Connector P2 SUB D 15P Female Recommended metal hood MH Connectors MHDTZK15 K Recommended crimp socket Molex FL15S7 K121 Recommended crimp contacts Molex 1731120432 20 24 AWG Pin Function Standby Name 1 Output for external devices Y21 2 PA microphone PTT X22 3 PA microphone signal high 4mV X23 4 PA microphone shie...

Страница 3: ...Not used set to off 5 Not used set to off 6 Not used set to off BCD Wheel Turn wheel to choose presets for selected country Pos 0 CAN This position is used when the amplifier is connected to a CAN based control system from Standby The connected control system sets the functionality of the amplifier Please see the description for the control system regarding functionality and connection ...

Страница 4: ...ound will automatically be deactivated after 10 seconds Input X117 or X119 must be active to be able to use this function X113 20 mA max 1A 14 Ground MS 350 S114 10A 15 Yelp SE horn signal edge trigged Activate deactivate the sound The sound will automatically be deactivated after 10 seconds Input X117 or X119 must be active to be able to use this function X115 20 mA max 1A 16 Power Supply Amplifi...

Страница 5: ...p US horn signal edge trigged Activate deactivate the sound The sound will automatically be deactivated after 10 seconds Input X117 must be active to be able to use this function X113 20 mA max 1A 14 Ground MS 350 S114 10A 15 Yelp US horn signal edge trigged Activate deactivate the sound The sound will automatically be deactivated after 10 seconds Input X117 must be active to be able to use this f...

Страница 6: ...Hi Lo clean SE will be played for 2 cycles When activating more than one sound at the same time this input is used to change to next sound manually X115 20 mA max 1A 16 Power Supply Amplifier S116 10A 10A 17 Hi Lo clean SE continuous feed Activates the sound AND the output Beacon This input has higher priority than X119 and X121 if activated at the same time X117 20 mA max 1A 18 Beacon continuous ...

Страница 7: ...und Yelp SE will be played for 20 cycles When activating more than one sound at the same time this input is used to change to next sound manually X115 20 mA max 1A 16 Power Supply Amplifier S116 10A 10A 17 Hi Lo clean SE continuous feed Activates the sound AND the output Beacon This input has higher priority than X119 and X121 if activated at the same time X117 20 mA max 1A 18 Beacon continuous fe...

Страница 8: ...ble products www standbygroup se Standby will not be held liable for improper installation or use of this product Please follow all instructions provided Professional advice and proper installation of the Standby products by an authorized Standby Partner are recommended to provide maximum safety and function ...

Отзывы: